67 research outputs found

    Infection rates associated with epidural indwelling catheters for seven days or longer: systematic review and meta-analysis

    Get PDF
    BACKGROUND: To determine infection rate with use of epidural catheters in place for seven days or more. METHODS: Systematic review and pooled analysis of observational studies. RESULTS: Twelve studies with 4,628 patients (median 197 patients) provided information, of which nine (4,334 patients) were published after 1990. Eight studies (3,893 patients) were retrospective, and four studies (735 patients) prospective. Electronic searches identified three studies and searching reference lists nine. There were 257 catheter-related infections in total, of which 211 were superficial and 57 deep, giving rates of 6.1%, 4.6% and 1.2% respectively. Ten of the 12 studies had deep infection rates of 2% or less. The incidence of deep infection was 1 per 2391 days of treatment, or 0.4 per 1000 catheter treatment days. In nine studies (1503 patients), predominantly in cancer, and with average catheter duration of 74 days, the deep infection rate was 2.8%. The proportion of patients with infection of any type was higher in cancer patients with longer catheter duration. Limited numbers of events meant that no reliable estimate of the impact of prospective and retrospective design could be made. There appeared to be a relationship between catheter duration and infection rate from this and other recent estimates. Four of 57 (7%) patients with deep infection died. CONCLUSION: The best estimate is that one person in 35 with an epidural catheter in place for 74 days for relief of cancer pain can be expected to have a deep epidural infection, and that about 1 in 500 may die of infection-related causes. This is a most uncertain estimate given the limited nature of the evidence

    A randomized, double-blind comparison of OROS® hydromorphone and controlled-release morphine for the control of chronic cancer pain

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Long-acting opioid formulations are advocated for maintaining pain control in chronic cancer pain. OROS<sup>® </sup>hydromorphone is a sustained-release formulation of hydromorphone that requires dosing once daily to maintain therapeutic concentrations. The objective of this study was to demonstrate the clinical equivalence of immediate-release and sustained-release formulations of hydromorphone and morphine for chronic cancer pain.</p> <p>Methods</p> <p>200 patients with cancer pain (requiring ≤ 540 mg/d of oral morphine) participated in this double-blind, parallel-group trial. Patients were randomized to receive hydromorphone or morphine (immediate-release for 2–9 days, sustained-release for 10–15 days). Efficacy was assessed with the Brief Pain Inventory (BPI), investigator and patient global evaluations, Eastern Cooperative Oncology Group performance status, and the Mini-Mental State Examination. The primary endpoint was the 'worst pain in the past 24 hours' item of the BPI, in both the immediate-release and sustained-release study phases, with treatments deemed equivalent if the 95% confidence intervals (CI) of the between-group differences at endpoint were between -1.5 and 1.5. No equivalence limits were defined for secondary endpoints.</p> <p>Results</p> <p>Least-squares mean differences (95% CI) between groups were 0.2 (-0.4, 0.9) in the immediate-release phase and -0.8 (-1.6, -0.01) in the sustained-release phase (intent-to-treat population), indicating that the immediate-release formulations met the pre-specified equivalence criteria, but that the lower limit of the 95% CI (-1.6) was outside the boundary (-1.5) for the sustained-release formulations. BPI 'pain now PM' was significantly lower with OROS<sup>® </sup>hydromorphone compared with controlled-release morphine (least-squares mean difference [95% CI], -0.77 [-1.49, -0.05]; <it>p </it>= 0.0372). Scores for other secondary efficacy variables were similar between the two sustained-release treatments. At endpoint, > 70% of investigators and patients rated both treatments as good to excellent. The safety profiles of hydromorphone and morphine were similar and typical of opioid analgesics.</p> <p>Conclusion</p> <p>Equivalence was demonstrated for immediate-release formulations of hydromorphone and morphine, but not for the sustained-release formulations of OROS<sup>® </sup>hydromorphone and controlled-release morphine. The direction of the mean difference between the treatments (-0.8) and the out-of-range lower limit of the 95% CI (-1.6) were in favor of OROS<sup>® </sup>hydromorphone.</p> <p>Trial registration</p> <p>ClinicalTrials.gov: NCT0041054</p

    The use of opioids at the end of life: the knowledge level of Dutch physicians as a potential barrier to effective pain management

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pain is still one of the most frequently occurring symptoms at the end of life, although it can be treated satisfactorily in most cases if the physician has adequate knowledge. In the Netherlands, almost 60% of the patients with non-acute illnesses die at home where end of life care is coordinated by the general practitioner (GP); about 30% die in hospitals (cared for by clinical specialists), and about 10% in nursing homes (cared for by elderly care physicians).</p> <p>The research question of this study is: what is the level of knowledge of Dutch physicians concerning pain management and the use of opioids at the end of life?</p> <p>Methods</p> <p>A written questionnaire was sent to a random sample of physicians of specialties most often involved in end of life care in the Netherlands. The questionnaire was completed by 406 physicians, response rate 41%.</p> <p>Results</p> <p>Almost all physicians were aware of the most basal knowledge about opioids, e.g. that it is important for treatment purposes to distinguish nociceptive from neuropathic pain (97%). Approximately half of the physicians (46%) did not know that decreased renal function raises plasma concentration of morphine(-metabolites) and 34% of the clinical specialists erroneously thought opioids are the favoured drug for palliative sedation.</p> <p>Although 91% knew that opioids titrated against pain do not shorten life, 10% sometimes or often gave higher dosages than needed with the explicit aim to hasten death. About half felt sometimes or often pressured by relatives to hasten death by increasing opioiddosage.</p> <p>The large majority (83%) of physicians was interested in additional education about subjects related to the end of life, the most popular subject was opioid rotation (46%).</p> <p>Conclusions</p> <p>Although the basic knowledge of physicians was adequate, there seemed to be a lack of knowledge in several areas, which can be a barrier for good pain management at the end of life. From this study four areas emerge, in which it seems likely that an improvement can improve the quality of pain management at the end of life for many patients in the Netherlands: 1)palliative sedation; 2)expected effect of opioids on survival; and 3) opioid rotation.</p

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    La douleur hors des sentiers battus

    No full text

    Anaesthesia for the professional singer

    No full text
    corecore