1,079 research outputs found
Hepatitis B and Hepatocellular Carcinoma Screening Among Asian Americans: Survey of Safety Net Healthcare Providers
BackgroundPhysician patterns of screening for hepatitis B (HBV) and hepatocellular carcinoma (HCC) among Asian Americans are not well described.AimsTo describe HBV and HCC screening practices among providers with large Asian American populations.MethodsProviders within San Francisco's safety net system were surveyed with respect to HBV and HCC screening practices as well as knowledge, attitudes, and barriers to HCC screening.ResultsAmong the 109 respondents (response rate = 72%), 62% were aged >40, 65% female, 24% Asian, 87% primary care providers, and 48% had >25% Asian patients. Only 76% had screened >50% of their Asian patients for HBV and 43% had vaccinated >50% of eligible patients against HBV. Although 94% knew Asians were disproportionately affected by HCC, only 79% had screened for HCC in >50% of their Asian patients with chronic hepatitis B (CHB). A majority believed that HCC screening in CHB reduces HCC mortality (70%) and is cost-effective (57%). The most common HCC screening modality was AFP with abdominal ultrasound every 6-12 months (63%). Factors associated with HBV screening were familiarity with AASLD guidelines (OR 6.4, 95% CI 1.3-30.1, p = 0.02) and having vaccinated >50% of eligible patients against HBV (OR 2.2, 95% CI 1.1-4.5, p = 0.03). Factors associated with HCC screening using abdominal ultrasound every 6-12 months were having >25% Asian patients (OR = 4.5, 95% CI 1.3-15.3, p = 0.02) and higher HCC knowledge score (OR = 1.9 per item, 95% CI 1.01-3.6, p = 0.045).ConclusionsHBV and HCC screening rates and HBV vaccination among Asians from physician report is suboptimal. HCC screening is associated with having more Asian patients and higher provider knowledge. Provider education is essential in increasing rates of HBV and HCC screening among Asian Americans
The effect of age on the response to the pneumococcal polysaccharide vaccine
<p>Abstract</p> <p>Background</p> <p><it>Streptococcus pneumoniae </it>is a leading cause of morbidity and mortality in the elderly. To prevent invasive pneumococcal diseases, the 23-valent pneumococcal polysaccharide vaccine (PPV) is recommended in subjects over 65 years of age. Although it has been reported to provide approximately 50-80% protection against invasive disease in the general elderly population, there is still controversy as to the effectiveness of the PPV in the elderly.</p> <p>Methods</p> <p>To evaluate the immune response to the pneumococcal polysaccharide vaccine in the elderly, samples from young adults and elderly were obtained before and one month after vaccination. The quantitative and qualitative response to the vaccine were measured by the ELISA and opsonophagocytic killing assay for eight vaccine type serotypes (4, 6B, 9V, 14, 18C, 19A, 19F, 23F) and one vaccine-related serotype (6A).</p> <p>Results</p> <p>The response to the pneumococcal polysaccharide vaccine showed a similar response between adults and elderly when evaluated by the ELISA, however the functional activity of the antibodies elicited after vaccination were lower in the elderly group for more than half of the serotypes evaluated. In comparison of the antibody needed for 1:8 opsonic titer, more antibodies were needed in the elderly for serotypes Pn 4, 19F, 23F and 6A, suggesting the functional activity of antibody detected by the ELISA was lower in the elderly compared with the adult group for these serotypes. As for subjects with an opsonic titer <8 after vaccination, only one subject each for serotypes Pn 4, 9V and 6A were found in the adult group. However, up to 10 (30.3%) of the subjects did not show opsonic activity after vaccination in the elderly group for serotypes Pn 4, 9V, 14, 19A and 6A.</p> <p>Conclusions</p> <p>Although the amount of antibodies elicited were similar between the two age groups, distinct differences in function were noted. This report highlights the importance of a quantitative and qualitative evaluation of the immunogenic response to the PPV in the elderly age group.</p> <p>Trial registration</p> <p>This trial is registered with Clinical trials.gov. Registration number NCT00964769</p
Precise measurement of the W-boson mass with the CDF II detector
We have measured the W-boson mass MW using data corresponding to 2.2/fb of
integrated luminosity collected in proton-antiproton collisions at 1.96 TeV
with the CDF II detector at the Fermilab Tevatron collider. Samples consisting
of 470126 W->enu candidates and 624708 W->munu candidates yield the measurement
MW = 80387 +- 12 (stat) +- 15 (syst) = 80387 +- 19 MeV. This is the most
precise measurement of the W-boson mass to date and significantly exceeds the
precision of all previous measurements combined
Measurement of the Forward-Backward Asymmetry in the B -> K(*) mu+ mu- Decay and First Observation of the Bs -> phi mu+ mu- Decay
We reconstruct the rare decays , , and in a data sample
corresponding to collected in collisions at
by the CDF II detector at the Fermilab Tevatron
Collider. Using and decays we report the branching ratios. In addition, we report
the measurement of the differential branching ratio and the muon
forward-backward asymmetry in the and decay modes, and the
longitudinal polarization in the decay mode with respect to the squared
dimuon mass. These are consistent with the theoretical prediction from the
standard model, and most recent determinations from other experiments and of
comparable accuracy. We also report the first observation of the {\mathcal{B}}(B^0_s \to
\phi\mu^+\mu^-) = [1.44 \pm 0.33 \pm 0.46] \times 10^{-6}27 \pm 6B^0_s$ decay observed.Comment: 7 pages, 2 figures, 3 tables. Submitted to Phys. Rev. Let
Measurements of the properties of Lambda_c(2595), Lambda_c(2625), Sigma_c(2455), and Sigma_c(2520) baryons
We report measurements of the resonance properties of Lambda_c(2595)+ and
Lambda_c(2625)+ baryons in their decays to Lambda_c+ pi+ pi- as well as
Sigma_c(2455)++,0 and Sigma_c(2520)++,0 baryons in their decays to Lambda_c+
pi+/- final states. These measurements are performed using data corresponding
to 5.2/fb of integrated luminosity from ppbar collisions at sqrt(s) = 1.96 TeV,
collected with the CDF II detector at the Fermilab Tevatron. Exploiting the
largest available charmed baryon sample, we measure masses and decay widths
with uncertainties comparable to the world averages for Sigma_c states, and
significantly smaller uncertainties than the world averages for excited
Lambda_c+ states.Comment: added one reference and one table, changed order of figures, 17
pages, 15 figure
Search for a New Heavy Gauge Boson Wprime with Electron + missing ET Event Signature in ppbar collisions at sqrt(s)=1.96 TeV
We present a search for a new heavy charged vector boson decaying
to an electron-neutrino pair in collisions at a center-of-mass
energy of 1.96\unit{TeV}. The data were collected with the CDF II detector
and correspond to an integrated luminosity of 5.3\unit{fb}^{-1}. No
significant excess above the standard model expectation is observed and we set
upper limits on . Assuming standard
model couplings to fermions and the neutrino from the boson decay to
be light, we exclude a boson with mass less than
1.12\unit{TeV/}c^2 at the 95\unit{%} confidence level.Comment: 7 pages, 2 figures Submitted to PR
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
X-ray emission from the Sombrero galaxy: discrete sources
We present a study of discrete X-ray sources in and around the
bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival
Chandra observations with a total exposure of ~200 ks. With a detection limit
of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30
kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler
et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS
observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray
binaries (LMXBs). We quantify the differential luminosity functions (LFs) for
both the detected GC and field LMXBs, whose power-low indices (~1.1 for the
GC-LF and ~1.6 for field-LF) are consistent with previous studies for
elliptical galaxies. With precise sky positions of the GCs without a detected
X-ray source, we further quantify, through a fluctuation analysis, the GC LF at
fainter luminosities down to 1E35 erg/s. The derived index rules out a
faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent
findings in several elliptical galaxies and the bulge of M31. On the other
hand, the 2-6 keV unresolved emission places a tight constraint on the field
LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101
sources in the halo of Sombrero. The presence of these sources cannot be
interpreted as galactic LMXBs whose spatial distribution empirically follows
the starlight. Their number is also higher than the expected number of cosmic
AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray
surveys. We suggest that either the cosmic X-ray background is unusually high
in the direction of Sombrero, or a distinct population of X-ray sources is
present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV
The azimuthal anisotropy of charged particles in PbPb collisions at
nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS
detector at the LHC over an extended transverse momentum (pt) range up to
approximately 60 GeV. The data cover both the low-pt region associated with
hydrodynamic flow phenomena and the high-pt region where the anisotropies may
reflect the path-length dependence of parton energy loss in the created medium.
The anisotropy parameter (v2) of the particles is extracted by correlating
charged tracks with respect to the event-plane reconstructed by using the
energy deposited in forward-angle calorimeters. For the six bins of collision
centrality studied, spanning the range of 0-60% most-central events, the
observed v2 values are found to first increase with pt, reaching a maximum
around pt = 3 GeV, and then to gradually decrease to almost zero, with the
decline persisting up to at least pt = 40 GeV over the full centrality range
measured.Comment: Replaced with published version. Added journal reference and DO
- âŚ