2,658 research outputs found
Serum selenium concentration is associated with metabolic factors in the elderly: a cross-sectional study
<p>Abstract</p> <p>Background</p> <p>Selenium is an essential micronutrient known for its antioxidant function. However, the association of serum selenium with lipid profiles and fasting glucose are inconsistent in populations with average intake of selenium. Furthermore, there were few studies conducted specifically for the elderly. This study examined the relationship of serum selenium concentration with serum lipids and fasting glucose in the Taiwanese elderly population.</p> <p>Methods</p> <p>This was a cross-sectional study of 200 males and females aged 65-85 years (mean 71.5 Âą 4.6 years) from Taipei, Taiwan. Serum selenium was measured by inductively coupled plasma-mass spectrometer. The association between serum selenium and metabolic factors was examined using a multivariate linear regression analysis after controlling several confounders.</p> <p>Results</p> <p>The mean serum selenium concentration was 1.14 Îźmol/L, without significant difference between sexes. Total cholesterol, triglycerides, and LDL cholesterol increased significantly with serum selenium concentration (<it>P </it>< 0.001, <it>P </it>< 0.05 and <it>P </it>< 0.001, respectively) after adjusting for age, gender, anthropometric indices, lifestyle factors, and cardio-vascular risk factors in several linear regression models. Furthermore, there was a significantly positive association between serum selenium and serum fasting glucose concentrations (<it>P </it>< 0.05).</p> <p>Conclusions</p> <p>Total cholesterol, triglycerides, and LDL cholesterol, and fasting serum glucose concentrations increased significantly with serum selenium concentration in the Taiwanese elderly. The underlying mechanism warrants further research.</p
Location of logistics hubs at national and subnational level with consideration of the structure of the location choice
The location of logistic hubs is a strategic decision made after multicriteria analysis. This requires first the definition of quantitative or qualitative criteria that can be independent or partially conflicting. The decision of location can be made at different geographical levels (countries or regions). In this paper, we suggest a generic structuration of criteria by geographical level and by family for choosing hubs location, taking into account the involved structure of location choice, which is rarely done in the literature: sequential assessment (choice of a country, then of a region of this country) or simultaneous assessment (direct choice of a location among several regions belonging to different countries)
Performance issues in optical burst/packet switching
The final publication is available at Springer via http://dx.doi.org/10.1007/978-3-642-01524-3_8This chapter summarises the activities on optical packet switching (OPS) and optical burst switching (OBS) carried out by the COST 291 partners in the last 4 years. It consists of an introduction, five sections with contributions on five different specific topics, and a final section dedicated to the conclusions. Each section contains an introductive state-of-the-art description of the specific topic and at least one contribution on that topic. The conclusions give some points on the current situation of the OPS/OBS paradigms
Study of CP violation in Dalitz-plot analyses of B0 --> K+K-KS, B+ --> K+K-K+, and B+ --> KSKSK+
We perform amplitude analyses of the decays , , and , and measure CP-violating
parameters and partial branching fractions. The results are based on a data
sample of approximately decays, collected with the
BABAR detector at the PEP-II asymmetric-energy factory at the SLAC National
Accelerator Laboratory. For , we find a direct CP asymmetry
in of , which differs
from zero by . For , we measure the
CP-violating phase .
For , we measure an overall direct CP asymmetry of
. We also perform an angular-moment analysis of
the three channels, and determine that the state can be described
well by the sum of the resonances , , and
.Comment: 35 pages, 68 postscript figures. v3 - minor modifications to agree
with published versio
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
IL-12p35 induces expansion of IL-10 and IL-35-expressing regulatory B cells and ameliorates autoimmune disease
We thank Dr. Haohua Qian and Yichao Li (Visual function core, NEI, NIH) for technical assistance with OCT; Phyllis Silver (NEI, NIH) for EAU scoring of the eyes; Rashid Mahdi. M.J.M. for technical assistance with western blot analyses and Rafael Villasmil (NEI FLOW Cytometry Core facility) for assistance with FACS analysis.Peer reviewedPublisher PD
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV
The azimuthal anisotropy of charged particles in PbPb collisions at
nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS
detector at the LHC over an extended transverse momentum (pt) range up to
approximately 60 GeV. The data cover both the low-pt region associated with
hydrodynamic flow phenomena and the high-pt region where the anisotropies may
reflect the path-length dependence of parton energy loss in the created medium.
The anisotropy parameter (v2) of the particles is extracted by correlating
charged tracks with respect to the event-plane reconstructed by using the
energy deposited in forward-angle calorimeters. For the six bins of collision
centrality studied, spanning the range of 0-60% most-central events, the
observed v2 values are found to first increase with pt, reaching a maximum
around pt = 3 GeV, and then to gradually decrease to almost zero, with the
decline persisting up to at least pt = 40 GeV over the full centrality range
measured.Comment: Replaced with published version. Added journal reference and DO
- âŚ