91 research outputs found

    Prospective randomized clinical trial evaluating the effects of two different implant collar designs on peri‐implant healing and functional osseointegration after 25 years

    Full text link
    Research on oral/dental intra-osseous implantology focuses primarily on discovering techniques that promote mechanical and/or biological osseointegration over the short-term. The present clinical research documents the effects of implant collar length, external versus internal connection collar design, and fixture surface microtexturing on bone and soft-tissue peri-implant healing after 25 years of function with complete mandibular dental prostheses.Objectives Evaluate the effects of two different machined‐collar lengths and designs on peri‐implant healing. Material and Methods An implant with a microtextured surface and 3.6mm‐long internal‐connection machined collar was compared to two implants that had an identical 1.2mm‐long external‐connection machined collar, but one had the microtextured surface while the other's was machined. Participants received the three implants, with microgap at the crest, alternately at five sites between mental foramen, and a full‐arch prosthesis. Peri‐implant bone levels were measured after 23 to 26 years of function. Keratinized tissue height, plaque, probing depth, bleeding, and purulence were also evaluated. Descriptive and mixed models for repeated\measures analyses were used, with Bonferroni correction for pairwise comparisons. Results Twenty‐two participants (110 implants) were evaluated at the 25‐year examination. Microtextured implants with the longer machined collar had significantly greater mean marginal bone loss (−1.77mm ± 0.18, mean ± SE) than machined (−0.85mm ± 0.18, p < .001) and microtextured (−1.00 ± 0.18mm, p < .001) implants with the shorter machined collar. Keratinized tissue height was greater for internal‐connection (0.74mm ± 0.10) versus external‐connection (0.51 ± 0.08, p = 0.01) microtextured implants. No differences were observed for plaque (p = 0.78), probing depth (p = 0.42), bleeding (p = 0.07), and purulence (p = 1.00). Implant survival rate was 99%. Conclusions Implants with the 1.2mm machined collar limited bone loss to 1mm, while those with the longer machined collar showed > 1.5mm loss after 25 years of function with microgap at the crest. Internal‐connection design and fixture surface microtexturing did not result in greater bone preservation

    Flexible Plug Repair for Shuttle Wing Leading Edge

    Get PDF
    In response to the Columbia Accident Investigation Board report, a plug repair kit has been developed to enable astronauts to repair the space shuttle's wing leading edge (WLE) during orbit. The plug repair kit consists of several 17.78- cm-diameter carbon/silicon carbide (C/SiC) cover plates of various curvatures that can be attached to the refractory carbon-carbon WLE panels using a TZM refractory metal attach mechanism. The attach mechanism is inserted through the damage in the WLE panel and, as it is tightened, the cover plate flexes to conform to the curvature of the WLE panel within 0.050 mm. An astronaut installs the repair during an extravehicular activity (EVA). After installing the plug repair, edge gaps are checked and the perimeter of the repair is sealed using a proprietary material, developed to fill cracks and small holes in the WLE

    Finding Apparent Horizons in Dynamic 3D Numerical Spacetimes

    Get PDF
    We have developed a general method for finding apparent horizons in 3D numerical relativity. Instead of solving for the partial differential equation describing the location of the apparent horizons, we expand the closed 2D surfaces in terms of symmetric trace--free tensors and solve for the expansion coefficients using a minimization procedure. Our method is applied to a number of different spacetimes, including numerically constructed spacetimes containing highly distorted axisymmetric black holes in spherical coordinates, and 3D rotating, and colliding black holes in Cartesian coordinates.Comment: 19 pages, 13 figures, LaTex, to appear in Phys. Rev. D. Minor changes mad

    Combined Forward-Backward Asymmetry Measurements in Top-Antitop Quark Production at the Tevatron

    Get PDF
    The CDF and D0 experiments at the Fermilab Tevatron have measured the asymmetry between yields of forward- and backward-produced top and antitop quarks based on their rapidity difference and the asymmetry between their decay leptons. These measurements use the full data sets collected in proton-antiproton collisions at a center-of-mass energy of s=1.96\sqrt s =1.96 TeV. We report the results of combinations of the inclusive asymmetries and their differential dependencies on relevant kinematic quantities. The combined inclusive asymmetry is AFBttˉ=0.128±0.025A_{\mathrm{FB}}^{t\bar{t}} = 0.128 \pm 0.025. The combined inclusive and differential asymmetries are consistent with recent standard model predictions

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Measurements of top-quark pair differential cross-sections in the eμe\mu channel in pppp collisions at s=13\sqrt{s} = 13 TeV using the ATLAS detector

    Get PDF

    Search for single production of vector-like quarks decaying into Wb in pp collisions at s=8\sqrt{s} = 8 TeV with the ATLAS detector

    Get PDF

    Measurement of the W boson polarisation in ttˉt\bar{t} events from pp collisions at s\sqrt{s} = 8 TeV in the lepton + jets channel with ATLAS

    Get PDF

    Measurement of the bbb\overline{b} dijet cross section in pp collisions at s=7\sqrt{s} = 7 TeV with the ATLAS detector

    Get PDF
    corecore