23 research outputs found

    Economic evaluation of screening for open angle glaucoma

    Get PDF
    Objectives: The aim of this study was to assess the cost-effectiveness of screening for open-angle glaucoma (OAG) in the United Kingdom, given that OAG is an important cause of blindness worldwide. Methods: A Markov model was developed to estimate lifetime costs and benefits of a cohort of patients facing, alternatively, screening or current opportunistic case finding strategies. Strategies, varying in how screening would be organized (e.g., invitation for assessment by a glaucoma-trained optometrist [GO] or for simple test assessment by a technician) were developed, and allowed for the progression of OAG and treatment effects. Data inputs were obtained from systematic reviews. Deterministic and probabilistic sensitivity analyses were performed. Results: Screening was more likely to be cost-effective as prevalence increased, for 40 year olds compared with 60 or 75 year olds, when the re-screening interval was greater (10 years), and for the technician strategy compared with the GO strategy. For each age cohort and at prevalence levels of ≀1 percent, the likelihood that either screening strategy would be more cost-effective than current practice was small. For those 40 years of age, “technician screening” compared with current practice has an incremental cost-effectiveness ratio (ICER) that society might be willing to pay when prevalence is 6 percent to 10 percent and at over 10 percent for 60 year olds. In the United Kingdom, the age specific prevalence of OAG is much lower. Screening by GO, at any age or prevalence level, was not associated with an ICER < ÂŁ30,000. Conclusions: Population screening for OAG is unlikely to be cost-effective but could be for specific subgroups at higher risk.This study was developed from a health technology assessment on the clinical and cost-effectiveness of screening for open-angle glaucoma (OAG), funded by the National Institute for Health Research Health Technology Assessment Programme (project no. 04/08/02).Peer reviewedAuthor versio

    The Accuracy of Accredited Glaucoma Optometrists in the Diagnosis and Treatment Recommendation for Glaucoma

    Get PDF
    Background/aims: To compare the diagnostic performance of accredited glaucoma optometrists (AGO) for both the diagnosis of, and decision to treat glaucoma with that of routine hospital eye care against a reference standard of expert opinion, i.e. consultant ophthalmologist with a special interest in glaucoma. Methods: A directly comparative, masked, performance study was performed in Grampian, Scotland. 165 people were invited to participate and, of those, 100 (61%) were examined. People suspected of having glaucoma underwent a full ophthalmic assessment both in a newly established, community optometry led, glaucoma management scheme and in a consultant led hospital eye service within a month. Results: The agreement between the AGO and the consultant ophthalmologist in the diagnosis of glaucoma was substantial (89%, kappa = 0.703, SE=0.083). The agreement regarding the need for treatment was also substantial (88%, kappa = 0.716, SE =0.076). The agreement between the trainee ophthalmologists and the consultant ophthalmologist in the diagnosis of glaucoma and treatment recommendation were moderate (83%, kappa = 0.541, SE = 0.098, SE = 0.98; and 81%, kappa = 0.553, SE = 0.90, respectively). The diagnostic accuracy of the optometrists in detecting glaucoma in this population was high for specificity (0.93 [95% CI 0.85 to 0.97]) but lower for sensitivity at 0.76 (95% CI 0.57 to 0.89). The performance was similar when accuracy was assessed for treatment recommendation (sensitivity, 0.73[95% CI 0.57 to 0.85]; specificity 0.96[95% CI 0.88 to 0.99]). The differences in sensitivity and specificity between AGO and junior ophthalmologist was not statistically significant.Conclusions: Community optometrists trained in glaucoma provided satisfactory decisions regarding diagnosis and initiation of treatment for glaucoma. With such additional training in glaucoma optometrists are at least as accurate as junior ophthalmologists but some cases of glaucoma missed.Chief Scientist Office of the Scottish Executive Health Departmen

    Efficacy and safety of using mesh or grafts in surgery for anterior and/or posterior vaginal wall prolapse: systematic review and meta-analysis.

    Get PDF
    Background The efficacy and safety of mesh/graft in surgery for anterior or posterior pelvic organ prolapse is uncertain. Objectives To systematically review the efficacy and safety of mesh/graft for anterior or posterior vaginal wall prolapse surgery. Search strategy Electronic databases and conference proceedings were searched, experts and manufacturers contacted and reference lists of retrieved papers scanned. Selection criteria Randomised controlled trials (RCTs), non-randomised comparative studies, registries, case series involving at least 50 women, and RCTs published as conference abstracts from 2005 onwards. Data collection and analysis One reviewer screened titles/abstracts, undertook data extraction, and assessed study quality. Data analysis was conducted for three subgroups: anterior, posterior, and anterior and/or posterior repair (not reported separately). Results Forty-nine studies involving 4569 women treated with mesh/graft were included. Study quality was generally high. Median follow up was 13 months (range 1 to 51). In anterior repair, there was short-term evidence that mesh/graft (any type) significantly reduced objective prolapse recurrence rates compared with no mesh/graft (relative risk 0.48, 95% CI 0.32-0.72). Non-absorbable synthetic mesh had a significantly lower objective prolapse recurrence rate (8.8%, 48/548) than absorbable synthetic mesh (23.1%, 63/273) and biological graft (17.9%, 186/1041), but a higher erosion rate (10.2%, 68/666) than synthetic mesh (0.7%, 1/147) and biological graft (6.0%, 35/581). There was insufficient information to compare any of the other outcomes regardless of prolapse type. Conclusion Evidence for most outcomes was too sparse to provide meaningful conclusions. Rigorous long-term RCTs are required to determine the comparative efficacy of using mesh/graft.The National Institute for Health and Clinical Excellence Interventional Procedures Programme

    Systematic review of the agreement of tonometers with goldmann applanation tonometry

    Get PDF
    This review was part of the Surveillance for Ocular Hypertension study funded by the UK National Institute for Health Research Health Technology Assessment Programme (Project No. 07/46/02). J.C. held a Medical Research Council UK fellowship (G0601938). AA-B was a grantholder on an AstraZeneca (London, UK) funded study of a new medication for glaucoma. The Health Services Research Unit receives core funding from the Chief Scientist Office of the Scottish Government Health Directorates. Views and opinions expressed are those of the authors and do not necessarily reflect those of the Chief Scientist Office, National Institute for Health Research Health Technology Assessment Programme, or the Department of Health. None of the funders had a role in the design or conduct of this researchPeer reviewedPostprin

    The clinical effectiveness and cost-effectiveness of screening for open angle glaucoma : a systematic review and economic evaluation

    Get PDF
    Objectives: To assess whether open angle glaucoma (OAG) screening meets the UK National Screening Committee criteria, to compare screening strategies with case finding, to estimate test parameters, to model estimates of cost and cost-effectiveness, and to identify areas for future research. Data sources: Major electronic databases were searched up to December 2005. Review methods: Screening strategies were developed by wide consultation. Markov submodels were developed to represent screening strategies. Parameter estimates were determined by systematic reviews of epidemiology, economic evaluations of screening, and effectiveness (test accuracy, screening and treatment). Tailored highly sensitive electronic searches were undertaken. Results: Most potential screening tests reviewed had an estimated specificity of 85% or higher. No test was clearly most accurate, with only a few, heterogeneous studies for each test. No randomised controlled trials (RCTs) of screening were identified. Based on two treatment RCTs, early treatment reduces the risk of progression. Extrapolating from this, and assuming accelerated progression with advancing disease severity, without treatment the mean time to blindness in at least one eye was approximately 23 years, compared to 35 years with treatment. Prevalence would have to be about 3–4% in 40 year olds with a screening interval of 10 years to approach costeffectiveness. It is predicted that screening might be cost-effective in a 50-year-old cohort at a prevalence of 4% with a 10-year screening interval. General population screening at any age, thus, appears not to be cost-effective. Selective screening of groups with higher prevalence (family history, black ethnicity) might be worthwhile, although this would only cover 6% of the population. Extension to include other at-risk cohorts (e.g. myopia and diabetes) would include 37% of the general population, but the prevalence is then too low for screening to be considered cost-effective. Screening using a test with initial automated classification followed by assessment by a specialised optometrist, for test positives, was more cost-effective than initial specialised optometric assessment. The cost-effectiveness of the screening programme was highly sensitive to the perspective on costs (NHS or societal). In the base-case model, the NHS costs of visual impairment were estimated as £669. If annual societal costs were £8800, then screening might be considered cost-effective for a 40-year-old cohort with 1% OAG prevalence assuming a willingness to pay of £30,000 per quality-adjusted life-year. Of lesser importance were changes to estimates of attendance for sight tests, incidence of OAG, rate of progression and utility values for each stage of OAG severity. Cost-effectiveness was not particularly sensitive to the accuracy of screening tests within the ranges observed. However, a highly specific test is required to reduce large numbers of false-positive referrals. The findings that population screening is unlikely to be cost-effective are based on an economic model whose parameter estimates have considerable uncertainty. In particular, if rate of progression and/or costs of visual impairment are higher than estimated then screening could be cost-effective. Conclusions: While population screening is not costeffective, the targeted screening of high-risk groups may be. Procedures for identifying those at risk, for quality assuring the programme, as well as adequate service provision for those screened positive would all be needed. Glaucoma detection can be improved by increasing attendance for eye examination, and improving the performance of current testing by either refining practice or adding in a technology-based first assessment, the latter being the more cost-effective option. This has implications for any future organisational changes in community eye-care services. Further research should aim to develop and provide quality data to populate the economic model, by conducting a feasibility study of interventions to improve detection, by obtaining further data on costs of blindness, risk of progression and health outcomes, and by conducting an RCT of interventions to improve the uptake of glaucoma testing.Peer reviewedPublisher PD

    It's not what you do it's the way that it's measured: quality assessment of minor ailment management in community pharmacies:Quality assessment of minor ailment management in community pharmacies

    Get PDF
    Background: Effective management of minor ailments in community pharmacies could reduce the burden on alternative high-cost services (general practices, Emergency Departments). Evidence is needed regarding the appropriateness of management of these conditions in community pharmacies. Objective: To explore the appropriateness of minor ailment management in community pharmacies. Setting: Prospective, observational study of simulated patient (SP) visits to community pharmacies in Grampian (Scotland) and East Anglia (England). Method: Eighteen pharmacies (nine per centre) were recruited within a 25-mile radius of Aberdeen or Norwich. Consultations for four minor ailments were evaluated: back pain; vomiting/diarrhoea; sore throat; and eye discomfort. Each pharmacy received one SP visit per ailment (four visits/pharmacy; 72 visits total). Visits were audio-recorded and SPs completed a data collection form immediately after each visit. Primary Outcome Measure: Each SP consultation was assessed for appropriateness against product licence, practice guidelines and study-specific consensus standards developed by a multi-disciplinary consensus panel. Results: Evaluable data were available for 68/72 (94.4%) visits. Most (96%) visits resulted in the sale of a product; advice alone was the outcome of three visits. All product sales complied with the product licence, 52 (76%) visits complied with practice guidelines and seven visits achieved a ‘basic’ standard according to the consensus standard. Conclusion: Appropriateness of care varied according to the standard used. Pharmacy-specific quality standards are needed which are realistic and relevant to the pharmacy context and which reflect legal and clinical guidelines to promote the safe and effective management of minor ailments in this setting

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Screening tests for detecting open-angle glaucoma : systematic review and meta-analysis

    Get PDF
    PURPOSE. To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG). METHODS. Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negatives were included. Meta-analysis was undertaken using the hierarchical summary receiver operating characteristic model. RESULTS. Forty studies enrolling over 48,000 people reported nine tests. Most tests were reported by only a few studies. Frequency-doubling technology (FDT; C-20-1) was significantly more sensitive than ophthalmoscopy (30, 95% credible interval [CrI] 0-62) and Goldmann applanation tonometry (GAT; 45, 95% CrI 17-68), whereas threshold standard automated perimetry (SAP) and Heidelberg Retinal Tomograph (HRT II) were both more sensitive than GAT (41, 95% CrI 14-64 and 39, 95% CrI 3-64, respectively). GAT was more specific than both FDT C-20-5 (19, 95% CrI 0-53) and threshold SAP (14, 95% CrI 1-37). Judging performance by diagnostic odds ratio, FDT, oculokinetic perimetry, and HRT II are promising tests. Ophthalmoscopy, SAP, retinal photography, and GAT had relatively poor performance as single tests. These findings are based on heterogeneous data of limited quality and as such are associated with considerable uncertainty. CONCLUSIONS. No test or group of tests was clearly superior for glaucoma screening. Further research is needed to evaluate the comparative accuracy of the most promising tests. (Invest Ophthalmol Vis Sci. 2008;49:5373-5385) DOI: 10.1167/iovs.07-1501PostprintPeer reviewe
    corecore