    Morphometric, weight, viability, and germination analysis of castor bean seeds (Ricinus communis) under two temperature and relative humidity conditions

    Get PDF
    Objective: Morphometric evaluation, weight, viability and germination under two conditions of temperature and relative humidity in sixteen local varieties of castor beans (Ricinus communis) from various states of Mexico (E1-E16) including two commercial varieties (k75B and k93B) were analyzed. Design/methodology/approach: The morphometric characteristics were: area, Elongation Index (IE) and Feret's diameter (DF), by means of a vision system. The viability and germination tolerance (germination percentage (% germination), germination speed (VG) and emergence speed index (IVE)), were evaluated under two conditions of relative humidity and temperature (T1- HR 80%/T20ÂșC ; T2- HR 30%/T40ÂșC), under a randomized complete block experiment design with four replicates of 75 seeds. Results: There are morphometric differences (IE, area and DF) between and within the study varieties. There is a significant difference between T1 and T2 in days of radicle emergence (11.6 in T2 and 44.71 in T1), germination percentage (T1: 48.37 and T2: 56%), IVE (T1:34.07+12.72 and T2: 77.02+ 23.78) and VG (T1: 9.93 and T2: 24.60). The results obtained show that there is a positive correlation between the morphometric properties and the germination percentage under T1; but in T2 no correlation was observed. The Limitations on study/implications: The study did not imply limitations. Findings/conclusions: Two local varieties E4 and E15 with productive potential higher than 93% under T1 were found; and under T2 the local varieties E3 and E16 with a productive potential greater than 78%, with respect to the commercial variety k75B showed a better performance under T1 (89.75%) than under T2 (78.67%).Objective: To analyze the morphometric, weight, viability, and germination evaluation under two temperature and relative humidity conditions, in sixteen local varieties of castor bean (Ricinus communis) from several states of Mexico (E1-E16), as well as two commercial varieties (k75B and k93B). Design/Methodology/Approach: The following morphometric characteristics were analyzed using a vision system: area, elongation index (EI), and Feret's diameter (FD). Viability and germination tolerance (germination percentage (GP)), germination speed (GS), and emergence speed index (ESI)) were evaluated under two conditions of relative humidity and temperature (T1 - RH 80%/T 20ÂșC; T2 - RH 30%/T 40ÂșC), using a completely randomized block experiment design, with four replicates of 75 seeds. Results: There are morphometric differences (EI, area, and FD) between and within the study varieties. There are significant differences between T1 and T2 regarding the following variables: days of radicle emergence (T1: 44.71 and T2:11.6), germination percentage (T1: 48.37 and T2: 56%), ESI (T1: 34.07+12.72 and T2: 77.02+ 23.78), and GS (T1: 9.93 and T2: 24.60). The results obtained show a positive correlation between the morphometric properties and the germination percentage in T1; however, there was no correlation in T2. Study Limitations/Implications: There were no limitations to carry out this study. Findings/Conclusions: The E4 and E15 local varieties obtained a >93% productive potential in T1, while the E3 and E16 local varieties obtained a >78% productive potential in T2. Meanwhile, the k75B commercial variety had a better performance in T1 (89.75%) than in T2 (78.67%)

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    The impact of SARS-CoV-2 in dementia across Latin America : A call for an urgent regional plan and coordinated response

    Get PDF
    The SARS-CoV-2 global pandemic will disproportionately impact countries with weak economies and vulnerable populations including people with dementia. Latin American and Caribbean countries (LACs) are burdened with unstable economic development, fragile health systems, massive economic disparities, and a high prevalence of dementia. Here, we underscore the selective impact of SARS-CoV-2 on dementia among LACs, the specific strain on health systems devoted to dementia, and the subsequent effect of increasing inequalities among those with dementia in the region. Implementation of best practices for mitigation and containment faces particularly steep challenges in LACs. Based upon our consideration of these issues, we urgently call for a coordinated action plan, including the development of inexpensive mass testing and multilevel regional coordination for dementia care and related actions. Brain health diplomacy should lead to a shared and escalated response across the region, coordinating leadership, and triangulation between governments and international multilateral networks

    Regulation of proteasome assembly and activity in health and disease

    Get PDF

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    Commissioning and performance of the CMS silicon strip tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPDuring autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance

    Search for new physics in multijet events with at least one photon and large missing transverse momentum in proton-proton collisions at 13 TeV

    Get PDF
    A search for new physics in final states consisting of at least one photon, multiple jets, and large missing transverse momentum is presented, using proton-proton collision events at a center-of-mass energy of 13 TeV. The data correspond to an integrated luminosity of 137 fb−1, recorded by the CMS experiment at the CERN LHC from 2016 to 2018. The events are divided into mutually exclusive bins characterized by the missing transverse momentum, the number of jets, the number of b-tagged jets, and jets consistent with the presence of hadronically decaying W, Z, or Higgs bosons. The observed data are found to be consistent with the prediction from standard model processes. The results are interpreted in the context of simplified models of pair production of supersymmetric particles via strong and electroweak interactions. Depending on the details of the signal models, gluinos and squarks of masses up to 2.35 and 1.43 TeV, respectively, and electroweakinos of masses up to 1.23 TeV are excluded at 95% confidence level
    • 

    corecore