19,465 research outputs found

    Virtual reality training and assessment in laparoscopic rectum surgery

    Get PDF
    Background: Virtual-reality (VR) based simulation techniques offer an efficient and low cost alternative to conventional surgery training. This article describes a VR training and assessment system in laparoscopic rectum surgery. Methods: To give a realistic visual performance of interaction between membrane tissue and surgery tools, a generalized cylinder based collision detection and a multi-layer mass-spring model are presented. A dynamic assessment model is also designed for hierarchy training evaluation. Results: With this simulator, trainees can operate on the virtual rectum with both visual and haptic sensation feedback simultaneously. The system also offers surgeons instructions in real time when improper manipulation happens. The simulator has been tested and evaluated by ten subjects. Conclusions: This prototype system has been verified by colorectal surgeons through a pilot study. They believe the visual performance and the tactile feedback are realistic. It exhibits the potential to effectively improve the surgical skills of trainee surgeons and significantly shorten their learning curve. © 2014 John Wiley & Sons, Ltd

    Cancellous bone and theropod dinosaur locomotion. Part I—an examination of cancellous bone architecture in the hindlimb bones of theropods

    Get PDF
    This paper is the first of a three-part series that investigates the architecture of cancellous (‘spongy’) bone in the main hindlimb bones of theropod dinosaurs, and uses cancellous bone architectural patterns to infer locomotor biomechanics in extinct non-avian species. Cancellous bone is widely known to be highly sensitive to its mechanical environment, and has previously been used to infer locomotor biomechanics in extinct tetrapod vertebrates, especially primates. Despite great promise, cancellous bone architecture has remained little utilized for investigating locomotion in many other extinct vertebrate groups, such as dinosaurs. Documentation and quantification of architectural patterns across a whole bone, and across multiple bones, can provide much information on cancellous bone architectural patterns and variation across species. Additionally, this also lends itself to analysis of the musculoskeletal biomechanical factors involved in a direct, mechanistic fashion. On this premise, computed tomographic and image analysis techniques were used to describe and analyse the three-dimensional architecture of cancellous bone in the main hindlimb bones of theropod dinosaurs for the first time. A comprehensive survey across many extant and extinct species is produced, identifying several patterns of similarity and contrast between groups. For instance, more stemward non-avian theropods (e.g. ceratosaurs and tyrannosaurids) exhibit cancellous bone architectures more comparable to that present in humans, whereas species more closely related to birds (e.g. paravians) exhibit architectural patterns bearing greater similarity to those of extant birds. Many of the observed patterns may be linked to particular aspects of locomotor biomechanics, such as the degree of hip or knee flexion during stance and gait. A further important observation is the abundance of markedly oblique trabeculae in the diaphyses of the femur and tibia of birds, which in large species produces spiralling patterns along the endosteal surface. Not only do these observations provide new insight into theropod anatomy and behaviour, they also provide the foundation for mechanistic testing of locomotor hypotheses via musculoskeletal biomechanical modelling

    Energetic Instability Unjams Sand and Suspension

    Full text link
    Jamming is a phenomenon occurring in systems as diverse as traffic, colloidal suspensions and granular materials. A theory on the reversible elastic deformation of jammed states is presented. First, an explicit granular stress-strain relation is derived that captures many relevant features of sand, including especially the Coulomb yield surface and a third-order jamming transition. Then this approach is generalized, and employed to consider jammed magneto- and electro-rheological fluids, again producing results that compare well to experiments and simulations.Comment: 9 pages 2 fi

    Modulating the Perceived Softness of Real Objects Through Wearable Feel-Through Haptics

    Get PDF
    In vision, Augmented Reality (AR) allows the superposition of digital content on real-world visual information, relying on the well-established See-through paradigm. In the haptic domain, a putative Feel-through wearable device should allow to modify the tactile sensation without masking the actual cutaneous perception of the physical objects. To the best of our knowledge, a similar technology is still far to be effectively implemented. In this work, we present an approach that allows, for the first time, to modulate the perceived softness of real objects using a Feel-through wearable that uses a thin fabric as interaction surface. During the interaction with real objects, the device can modulate the growth of the contact area over the fingerpad without affecting the force experienced by the user, thus modulating the perceived softness. To this aim, the lifting mechanism of our system warps the fabric around the fingerpad in a way proportional to the force exerted on the specimen under exploration. At the same time, the stretching state of the fabric is controlled to keep a loose contact with the fingerpad. We demonstrated that different softness perceptions for the same specimens can be elicited, by suitably controlling the lifting mechanism of the system

    Using The Polynomial Particle-In-Cell Method For Liquid-Fabric Interaction

    Full text link
    Liquid-fabric interaction simulations using particle-in-cell (PIC) based models have been used to simulate a wide variety of phenomena and yield impressive visual results. However, these models suffer from numerical damping due to the data interpolation between the particles and grid. Our paper addresses this by using the polynomial PIC (PolyPIC) model instead of the affine PIC (APIC) model that is used in current state-of-the-art wet cloth models. The affine transfers of the APIC model are replaced by the higher order polynomials of PolyPIC, thus reducing numerical dissipation and improving resolution of vorticial details. This improved energy preservation enables more dynamic simulations to be generated although this is at an increased computational cost.Comment: 10 pages, 8 Figures, 2 Table

    Bone mechanical properties in healthy and diseased states

    Get PDF
    The mechanical properties of bone are fundamental to the ability of our skeletons to support movement and to provide protection to our vital organs. As such, deterioration in mechanical behavior with aging and/or diseases such as osteoporosis and diabetes can have profound consequences for individuals’ quality of life. This article reviews current knowledge of the basic mechanical behavior of bone at length scales ranging from hundreds of nanometers to tens of centimeters. We present the basic tenets of bone mechanics and connect them to some of the arcs of research that have brought the field to recent advances. We also discuss cortical bone, trabecular bone, and whole bones, as well as multiple aspects of material behavior, including elasticity, yield, fracture, fatigue, and damage. We describe the roles of bone quantity (e.g., density, porosity) and bone quality (e.g., cross-linking, protein composition), along with several avenues of future research.Author manuscrip

    W-FYD: a Wearable Fabric-based Display for Haptic Multi-Cue Delivery and Tactile Augmented Reality

    Get PDF
    Despite the importance of softness, there is no evidence of wearable haptic systems able to deliver controllable softness cues. Here, we present the Wearable Fabric Yielding Display (W-FYD), a fabric-based display for multi-cue delivery that can be worn on user's finger and enables, for the first time, both active and passive softness exploration. It can also induce a sliding effect under the finger-pad. A given stiffness profile can be obtained by modulating the stretching state of the fabric through two motors. Furthermore, a lifting mechanism allows to put the fabric in contact with the user's finger-pad, to enable passive softness rendering. In this paper, we describe the architecture of W-FYD, and a thorough characterization of its stiffness workspace, frequency response and softness rendering capabilities. We also computed device Just Noticeable Difference in both active and passive exploratory conditions, for linear and non-linear stiffness rendering as well as for sliding direction perception. The effect of device weight was also considered. Furthermore, performance of participants and their subjective quantitative evaluation in detecting sliding direction and softness discrimination tasks are reported. Finally, applications of W-FYD in tactile augmented reality for open palpation are discussed, opening interesting perspectives in many fields of human-machine interaction

    The bias-extension test for the analysis of in-plane shear properties of textile composite reinforcements and prepregs: a review

    Get PDF
    The bias-extension test is a rather simple experiment aiming to determine in-plane shear properties of textile composite reinforcements. However the mechanics during the test involves fibrous material at large shear strains and large rotations of the fibres. Several aspects are still being studied and are not yet modeled in a consensual manner. The standard analysis of the test is based on two assumptions: inextensibility of the fibers and rotations at the yarn crossovers without slippage. They lead to the development of zones with constant fibre orientations proper to the bias-extension test. Beyond the analysis of the test within these basic assumptions, the paper presents studies that have been carried out on the lack of verification of these hypothesis (slippage, tension in the yarns, effects of fibre bending). The effects of temperature, mesoscopic modeling and tension locking are also considered in the case of the bias-extension test
    • …
    corecore