96 research outputs found

    Retear of anterior cruciate ligament grafts in female basketball players: a case series

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Incidence of anterior cruciate ligament (ACL) injuries in young female basketball players is higher than that in male basketball players. Graft retears are more frequent with the increasing number of ACL reconstructions. The present study aimed to examine the incidence of retears in competitive female basketball players.</p> <p>Methods</p> <p>Sixty-four female basketball players (aged 12 to 29 years) who underwent primary anatomic double-bundle ACL reconstruction using hamstring grafts participated in the study. We investigated incidence, mechanism, and patient characteristics of ACL graft retears. Mann-Whitney <it>U </it>test was used for statistical analysis, and the level of significance was determined at <it>P </it>< 0.05.</p> <p>Results</p> <p>Six patients suffered from ACL graft retear (9.4%). Mean duration between primary ACL reconstruction and incidence of retears was 11.7 months. However, there were no other postoperative graft ruptures after 24 months. Primary injury and retear mechanisms varied by patient. At six months after the primary ACL reconstruction surgery, mean quadriceps and hamstring strengths were 81% and 87%, respectively, indicating favorable recovery of muscle strength. However, preoperative quadriceps and hamstring strength in the retear group were 65% and 71%, respectively. In particular, preoperative quadriceps strength in the retear group demonstrated a lower value than that in the uninjured group (<it>P </it>< 0.05).</p> <p>Conclusions</p> <p>We observed a high incidence of ACL graft retears in competitive female basketball players, as previously reported. Considering the timing of graft retear occurrences, an early return to playing basketball should be avoided following ACL reconstruction. Closer attention should be paid to player preoperative condition, as well as muscle strength and postoperative status.</p

    Anisotropy studies around the galactic centre at EeV energies with the Auger Observatory

    Get PDF
    Data from the Pierre Auger Observatory are analyzed to search for anisotropies near the direction of the Galactic Centre at EeV energies. The exposure of the surface array in this part of the sky is already significantly larger than that of the fore-runner experiments. Our results do not support previous findings of localized excesses in the AGASA and SUGAR data. We set an upper bound on a point-like flux of cosmic rays arriving from the Galactic Centre which excludes several scenarios predicting sources of EeV neutrons from Sagittarius AA. Also the events detected simultaneously by the surface and fluorescence detectors (the `hybrid' data set), which have better pointing accuracy but are less numerous than those of the surface array alone, do not show any significant localized excess from this direction.Comment: Matches published versio

    Treatment of osteochondral lesions of the talus: a systematic review

    Get PDF
    The aim of this study was to summarize all eligible studies to compare the effectiveness of treatment strategies for osteochondral defects (OCD) of the talus. Electronic databases from January 1966 to December 2006 were systematically screened. The proportion of the patient population treated successfully was noted, and percentages were calculated. For each treatment strategy, study size weighted success rates were calculated. Fifty-two studies described the results of 65 treatment groups of treatment strategies for OCD of the talus. One randomized clinical trial was identified. Seven studies described the results of non-operative treatment, 4 of excision, 13 of excision and curettage, 18 of excision, curettage and bone marrow stimulation (BMS), 4 of an autogenous bone graft, 2 of transmalleolar drilling (TMD), 9 of osteochondral transplantation (OATS), 4 of autologous chondrocyte implantation (ACI), 3 of retrograde drilling and 1 of fixation. OATS, BMS and ACI scored success rates of 87, 85 and 76%, respectively. Retrograde drilling and fixation scored 88 and 89%, respectively. Together with the newer techniques OATS and ACI, BMS was identified as an effective treatment strategy for OCD of the talus. Because of the relatively high cost of ACI and the knee morbidity seen in OATS, we conclude that BMS is the treatment of choice for primary osteochondral talar lesions. However, due to great diversity in the articles and variability in treatment results, no definitive conclusions can be drawn. Further sufficiently powered, randomized clinical trials with uniform methodology and validated outcome measures should be initiated to compare the outcome of surgical strategies for OCD of the talus

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Relationship between low Ankle-Brachial Index and rapid renal function decline in patients with atrial fibrillation: A prospective multicentre cohort study

    Get PDF
    OBJECTIVE: To investigate the relationship between Ankle-Brachial Index (ABI) and renal function progression in patients with atrial fibrillation (AF). DESIGN: Observational prospective multicentre cohort study. SETTING:Atherothrombosis Center of I Clinica Medica of 'Sapienza' University of Rome; Department of Medical and Surgical Sciences of University Magna Græcia of Catanzaro; Atrial Fibrillation Registry for Ankle-Brachial Index Prevalence Assessment-Collaborative Italian Study. PARTICIPANTS: 897 AF patients on treatment with vitamin K antagonists. MAIN OUTCOME MEASURES: The relationship between basal ABI and renal function progression, assessed by the estimated Glomerular Filtration Rate (eGFR) calculated with the CKD-EPI formula at baseline and after 2 years of follow-up. The rapid decline in eGFR, defined as a decline in eGFR >5 mL/min/1.73 m(2)/year, and incident eGFR<60 mL/min/1.73 m(2) were primary and secondary end points, respectively. RESULTS: Mean age was 71.8±9.0 years and 41.8% were women. Low ABI (ie, ≤0.90) was present in 194 (21.6%) patients. Baseline median eGFR was 72.7 mL/min/1.73 m(2), and 28.7% patients had an eGFR60 mL/min/1.73 m(2), 153 (23.9%) had a reduction of the eGFR <60 mL/min/1.73 m(2). ABI ≤0.90 was also an independent predictor for incident eGFR<60 mL/min/1.73 m(2) (HR 1.851, 95% CI 1.205 to 2.845, p=0.005). CONCLUSIONS: In patients with AF, an ABI ≤0.90 is independently associated with a rapid decline in renal function and incident eGFR<60 mL/min/1.73 m(2). ABI measurement may help identify patients with AF at risk of renal function deterioration

    A Search for Photons with Energies Above 2X10(17) eV Using Hybrid Data from the Low-Energy Extensions of the Pierre Auger Observatory

    Get PDF
    Ultra-high-energy photons with energies exceeding 10(17) eV offer a wealth of connections to different aspects of cosmic-ray astrophysics as well as to gamma-ray and neutrino astronomy. The recent observations of photons with energies in the 10(15) eV range further motivate searches for even higher-energy photons. In this paper, we present a search for photons with energies exceeding 2 x 10(17) eV using about 5.5 yr of hybrid data from the low-energy extensions of the Pierre Auger Observatory. The upper limits on the integral photon flux derived here are the most stringent ones to date in the energy region between 10(17) and 10(18) eV

    CMS Data Processing Workflows during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe
    • …
    corecore