275 research outputs found

    The clinical implications of body surface area as a poor proxy for cardiac output

    Get PDF
    Background Prosthesis-patient mismatch (PPM), routinely used to characterize the degree of hemodynamic obstruction caused by a prosthetic heart valve, is associated with adverse patient outcomes after aortic valve replacement (AVR). In the common definition of PPM, the opening area of the valve is related to the patients' cardiac output, by indexing effective orifice area (EOA) with body surface area (BSA). The aim of this study is to assess the implications of using BSA as a proxy for cardiac output. Methods 744 patients with normal LV function underwent echocardiographic assessment after surgical AVR. To validate the use of BSA as a proxy for cardiac output, the relation between these variables was analyzed. The effects of BSA on the classification of PPM (EOAi = 20 mmHg and/or Doppler velocity index < 0.35) were estimated. Results There was a weak correlation between BSA and cardiac output (r: 0.29, 95% CI: 0.22;0.35), and cardiac output was not proportional to BSA (Cardiac output = 1.5 x BSA +1.9). As a result, the increased risk of patients with a large BSA to be labelled with PPM (OR: 5.2, 95% CI: 2.5,11 per m(2) BSA), was not reflected by a significantly higher risk of hemodynamic obstruction (OR: 1.5, 95% CI: 0.5,4.9 per m(2) BSA). Conclusions The current definition of PPM results in a systematic overestimation of hemodynamic obstruction in patients with a larger BSA, and we recommend cautious use in this subgroup.Thoracic Surger

    Unstable particles in matter at a finite temperature: the rho and omega mesons

    Full text link
    Unstable particles (such as the vector mesons) have an important role to play in low mass dilepton production resulting from heavy ion collisions and this has been a subject of several investigations. Yet subtleties, such as the implications of the generalization of the Breit-Wigner formula for nonzero temperature and density, e.g. the question of collisional broadening, the role of Bose enhancement, etc., the possibility of the kinematic opening (or closing) of decay channels due to environmental effects, the problem of double counting through resonant and direct contributions, are often given insufficient emphasis. The present study attempts to point out these features using the rho and omega mesons as illustrative examples. The difference between the two versions of the Vector Meson Dominance Model in the present context is also presented. Effects of non-zero temperature and density, through vector meson masses and decay widths, on dilepton spectra are studied, for concreteness within the framework of a Walecka-type model, though most of the basic issues highlighted apply to other scenarios as well.Comment: text and figures modifie

    The Planetary Nebula Luminosity Function at the Dawn of Gaia

    Full text link
    The [O III] 5007 Planetary Nebula Luminosity Function (PNLF) is an excellent extragalactic standard candle. In theory, the PNLF method should not work at all, since the luminosities of the brightest planetary nebulae (PNe) should be highly sensitive to the age of their host stellar population. Yet the method appears robust, as it consistently produces < 10% distances to galaxies of all Hubble types, from the earliest ellipticals to the latest-type spirals and irregulars. It is therefore uniquely suited for cross-checking the results of other techniques and finding small offsets between the Population I and Population II distance ladders. We review the calibration of the method and show that the zero points provided by Cepheids and the Tip of the Red Giant Branch are in excellent agreement. We then compare the results of the PNLF with those from Surface Brightness Fluctuation measurements, and show that, although both techniques agree in a relative sense, the latter method yields distances that are ~15% larger than those from the PNLF. We trace this discrepancy back to the calibration galaxies and argue that, due to a small systematic error associated with internal reddening, the true distance scale likely falls between the extremes of the two methods. We also demonstrate how PNLF measurements in the early-type galaxies that have hosted Type Ia supernovae can help calibrate the SN Ia maximum magnitude-rate of decline relation. Finally, we discuss how the results from space missions such as Kepler and Gaia can help our understanding of the PNLF phenomenon and improve our knowledge of the physics of local planetary nebulae.Comment: 12 pages, invited review at the conference "The Fundamental Cosmic Distance Scale: State of the Art and Gaia Perspective", to appear in Astrophysics and Space Scienc

    Chiral Symmetry and light resonances in hot and dense matter

    Get PDF
    We present a study of the ππ\pi\pi scattering amplitude in the σ\sigma and ρ\rho channels at finite temperature and nuclear density within a chiral unitary framework. Meson resonances are dynamically generated in our approach, which allows us to analyze the behavior of their associated scattering poles when the system is driven towards chiral symmetry restoration. Medium effects are incorporated in three ways: (a) by thermal corrections of the unitarized scattering amplitudes, (b) by finite nuclear density effects associated to a renormalization of the pion decay constant, and complementarily (c) by extending our calculation of the scalar-isoscalar channel to account for finite nuclear density and temperature effects in a microscopic many-body implementation of pion dynamics. Our results are discussed in connection with several phenomenological aspects relevant for nuclear matter and Heavy-Ion Collision experiments, such as ρ\rho mass scaling vs broadening from dilepton spectra and chiral restoration signals in the σ\sigma channel. We also elaborate on the molecular nature of ππ\pi\pi resonances.Comment: 14 pages, 14 figures. Contribution to Hard Probes 2008, Illa de A Toxa, Spain, June 8th-14th 200

    A controlled trial of rivaroxaban after transcatheter aortic-valve replacement

    Get PDF
    Background: whether the direct factor Xa inhibitor rivaroxaban can prevent thromboembolic events after transcatheter aortic-valve replacement (TAVR) is unclear. Methods: we randomly assigned 1644 patients without an established indication for oral anticoagulation after successful TAVR to receive rivaroxaban at a dose of 10 mg daily (with aspirin at a dose of 75 to 100 mg daily for the first 3 months) (rivaroxaban group) or aspirin at a dose of 75 to 100 mg daily (with clopidogrel at a dose of 75 mg daily for the first 3 months) (antiplatelet group). The primary efficacy outcome was the composite of death or thromboembolic events. The primary safety outcome was major, disabling, or life-threatening bleeding. The trial was terminated prematurely by the data and safety monitoring board because of safety concerns. Results: after a median of 17 months, death or a first thromboembolic event (intention-to-treat analysis) had occurred in 105 patients in the rivaroxaban group and in 78 patients in the antiplatelet group (incidence rates, 9.8 and 7.2 per 100 person-years, respectively; hazard ratio with rivaroxaban, 1.35; 95% confidence interval [CI], 1.01 to 1.81; P = 0.04). Major, disabling, or life-threatening bleeding (intention-to-treat analysis) had occurred in 46 and 31 patients, respectively (4.3 and 2.8 per 100 person-years; hazard ratio, 1.50; 95% CI, 0.95 to 2.37; P = 0.08). A total of 64 deaths occurred in the rivaroxaban group and 38 in the antiplatelet group (5.8 and 3.4 per 100 person-years, respectively; hazard ratio, 1.69; 95% CI, 1.13 to 2.53). Conclusions: in patients without an established indication for oral anticoagulation after successful TAVR, a treatment strategy including rivaroxaban at a dose of 10 mg daily was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than an antiplatelet-based strategy. (Funded by Bayer and Janssen Pharmaceuticals; GALILEO ClinicalTrials.gov number, NCT02556203.)

    Curva de anticorpos pós-vacinais em ovinos imunizados com uma ou duas doses de bacterina oleosa anti-leptospirose, produzida com a sorovariedade Hardjo, tipo Hardjoprajitno, estirpe Norma, isolada no Brasil

    Full text link
    Foi comparado o nível de anticorpos de ovelhas imunizadas com uma ou duas doses de bacterina oleosa produzida com a sorovariedade Hardjo, tipo Hardjoprajitno, estirpe Norma, isolada da urina de bovino no Brasil. Culturas de 2x10(8) leptospiras/mL foram inativadas com formalina a 0,3%, à concentração final e emulsionada em óleo Emulsigen® 12%. A dose da vacina foi padronizada para a concentração de 1x10(8) leptospiras/mL. Quarenta ovinos adultos, da raça Santa Inês, de um rebanho livre de leptospirose por exames clínicos e sorológicos durante um ano foram escolhidos para o experimento. O grupo A (n=15) recebeu duas doses de 3,0mL da vacina por via subcutânea, com intervalo de 30 dias. O grupo B (n=15) recebeu dose única de 3,0mL, via subcutânea e o grupo C (controle) recebeu uma dose subcutânea de 3,0mL de solução 0,85% de cloreto de sódio. Os títulos de anticorpos pós-vacinação foram mensurados pelo teste de soroaglutinação microscópica (SAM) e um teste imunoenzimático (ELISA) a cada 30 dias durante 120 dias. Os títulos dos grupos A e B na primeira colheita variaram de 80 a 160. No grupo A, após a segunda dose, os títulos aumentaram duas a quatro vezes, até 3.200, enquanto no grupo B os títulos de aglutininas foram menores que 160 e diminuíram uma a duas vezes após 60 dias da vacinação. Utilizando-se dose única, os anticorpos persistiram por somente 30 dias e, com duas doses, com 30 dias de intervalo, os anticorpos foram detectáveis por 60 dias por meio do teste de SAM e 120 dias no teste de ELISA. Assim, o teste de SAM detectou títulos de IgM vacinal somente por 60 dias, enquanto o teste de ELISA foi capaz de detectar anticorpos durante os 120 dias. No grupo controle negativo, ocorreram no ELISA reações inespecíficas de títulos até 80, porém no SAM os títulos dos mesmos animais se mantiveram em zero. O teste de ELISA pode ser utilizado para medir anticorpos vacinais para a sorovariedade Hardjo, tipo Hardjoprajitno, estirpe Norma em ovinos

    Association between transcatheter aortic valve replacement and subsequent infective endocarditis and in-hospital death

    Get PDF
    Importance Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). Objective To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. Design, Setting, and Participants The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES Infective endocarditis and in-hospital mortality after infective endocarditis. Results A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care?associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients. Enterococci species and Staphylococcus aureus were the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio [OR], 1.03 per 1% increase; 95% CI, 1.00-1.05), heart failure (59.3% vs 23.7%; OR, 3.36; 95% CI, 1.74-6.45), and acute kidney injury (67.4% vs 31.6%; OR, 2.70; 95% CI, 1.42-5.11). The 2-year mortality rate was 66.7% (95% CI, 59.0%-74.2%; 132 deaths; 115 survivors). Conclusions and Relevance Among patients undergoing TAVR, younger age, male sex, history of diabetes mellitus, and moderate to severe residual aortic regurgitation were significantly associated with an increased risk of infective endocarditis. Patients who developed endocarditis had high rates of in-hospital mortality and 2-year mortality

    Searches for lepton-flavour-violating decays of the Higgs boson in s=13\sqrt{s}=13 TeV pp\mathit{pp} collisions with the ATLAS detector

    Get PDF
    This Letter presents direct searches for lepton flavour violation in Higgs boson decays, H → eτ and H → μτ , performed with the ATLAS detector at the LHC. The searches are based on a data sample of proton–proton collisions at a centre-of-mass energy √s = 13 TeV, corresponding to an integrated luminosity of 36.1 fb−1. No significant excess is observed above the expected background from Standard Model processes. The observed (median expected) 95% confidence-level upper limits on the leptonflavour-violating branching ratios are 0.47% (0.34+0.13−0.10%) and 0.28% (0.37+0.14−0.10%) for H → eτ and H → μτ , respectively.publishedVersio

    Combination of searches for Higgs boson pairs in pp collisions at \sqrts = 13 TeV with the ATLAS detector

    Get PDF
    This letter presents a combination of searches for Higgs boson pair production using up to 36.1 fb(-1) of proton-proton collision data at a centre-of-mass energy root s = 13 TeV recorded with the ATLAS detector at the LHC. The combination is performed using six analyses searching for Higgs boson pairs decaying into the b (b) over barb (b) over bar, b (b) over barW(+)W(-), b (b) over bar tau(+)tau(-), W+W-W+W-, b (b) over bar gamma gamma and W+W-gamma gamma final states. Results are presented for non-resonant and resonant Higgs boson pair production modes. No statistically significant excess in data above the Standard Model predictions is found. The combined observed (expected) limit at 95% confidence level on the non-resonant Higgs boson pair production cross-section is 6.9 (10) times the predicted Standard Model cross-section. Limits are also set on the ratio (kappa(lambda)) of the Higgs boson self-coupling to its Standard Model value. This ratio is constrained at 95% confidence level in observation (expectation) to -5.0 &lt; kappa(lambda) &lt; 12.0 (-5.8 &lt; kappa(lambda) &lt; 12.0). In addition, limits are set on the production of narrow scalar resonances and spin-2 Kaluza-Klein Randall-Sundrum gravitons. Exclusion regions are also provided in the parameter space of the habemus Minimal Supersymmetric Standard Model and the Electroweak Singlet Model. For complete list of authors see http://dx.doi.org/10.1016/j.physletb.2019.135103</p
    corecore