1,226 research outputs found
Spectroscopic Studies of Brooker\u27s Merocyanine in Zeolite L
Zeolites are porous, crystalline substances that have very unique atomic organizations which allow for the formation of complex channels within the crystals. Each type of zeolite has a distinct shape and structure. To better understand the properties of zeolite channels, a dye molecule known as Brooker’s merocyanine was inserted into Zeolite L. Maximum dye loading into the zeolite channels was achieved by altering different experimental variables, such as heat, solution concentration, stirring, cation exchange, and light exposure. X-ray diffraction was used to verify the synthesis of zeolites, the cation exchange process, and dye loading. UV-Vis spectroscopy was used to measure the amount of dye adsorbed by the zeolite. By using the UV-Vis absorbance values and Beer’s Law, the concentration of dye in the zeolites was determined. The results showed that an increase of heat and stirring correlated to an increase of adsorption of dye by the zeolite. Due to the light sensitivity of Brooker’s merocyanine, it was found that limiting the amount of light exposure of the dye solutions also resulted in higher dye adsorption by the zeolites. An increase of the concentration of the dye solution increased the rate of adsorption in the channels. However, exchanging the potassium ions found within the synthesized Zeolite L channels with smaller hydrogen ions did not have an affect on the adsorption of dye in the channels. Characterizing how to achieve a maximum of dye adsorption in the zeolites allows for a better understanding of how dye molecules interact within the zeolite channels
Mitochondrial Respiratory Capacity and Content Are Normal in Young Insulin-Resistant Obese Humans
Considerable debate exists about whether alterations in mitochondrial respiratory capacity and/or content play a causal role in the development of insulin resistance during obesity. The current study was undertaken to determine whether such alterations are present during the initial stages of insulin resistance in humans. Young (∼23 years) insulin-sensitive lean and insulin-resistant obese men and women were studied. Insulin resistance was confirmed through an intravenous glucose tolerance test. Measures of mitochondrial respiratory capacity and content as well as H(2)O(2) emitting potential and the cellular redox environment were performed in permeabilized myofibers and primary myotubes prepared from vastus lateralis muscle biopsy specimens. No differences in mitochondrial respiratory function or content were observed between lean and obese subjects, despite elevations in H(2)O(2) emission rates and reductions in cellular glutathione. These findings were apparent in permeabilized myofibers as well as in primary myotubes. The results suggest that reductions in mitochondrial respiratory capacity and content are not required for the initial manifestation of peripheral insulin resistance
Role of Complement Activation in Obliterative Bronchiolitis Post Lung Transplantation
Obliterative bronchiolitis (OB) post lung transplantation involves IL-17 regulated autoimmunity to type V collagen and alloimmunity, which could be enhanced by complement activation. However, the specific role of complement activation in lung allograft pathology, IL-17 production, and OB are unknown. The current study examines the role of complement activation in OB. Complement regulatory protein (CRP) (CD55, CD46, Crry/CD46) expression was down regulated in human and murine OB; and C3a, a marker of complement activation, was up regulated locally. IL-17 differentially suppressed Crry expression in airway epithelial cells in vitro. Neutralizing IL-17 recovered CRP expression in murine lung allografts and decreased local C3a production. Exogenous C3a enhanced IL-17 production from alloantigen or autoantigen (type V collagen) reactive lymphocytes. Systemically neutralizing C5 abrogated the development of OB, reduced acute rejection severity, lowered systemic and local levels of C3a and C5a, recovered CRP expression, and diminished systemic IL-17 and IL-6 levels. These data indicated that OB induction is in part complement dependent due to IL-17 mediated down regulation of CRPs on airway epithelium. C3a and IL-17 are part of a feed forward loop that may enhance CRP down regulation, suggesting that complement blockade could be a therapeutic strategy for OB
Pituitary blastoma: a pathognomonic feature of germ-line DICER1 mutations.
Individuals harboring germ-line DICER1 mutations are predisposed to a rare cancer syndrome, the DICER1 Syndrome or pleuropulmonary blastoma-familial tumor and dysplasia syndrome [online Mendelian inheritance in man (OMIM) #601200]. In addition, specific somatic mutations in the DICER1 RNase III catalytic domain have been identified in several DICER1-associated tumor types. Pituitary blastoma (PitB) was identified as a distinct entity in 2008, and is a very rare, potentially lethal early childhood tumor of the pituitary gland. Since the discovery by our team of an inherited mutation in DICER1 in a child with PitB in 2011, we have identified 12 additional PitB cases. We aimed to determine the contribution of germ-line and somatic DICER1 mutations to PitB. We hypothesized that PitB is a pathognomonic feature of a germ-line DICER1 mutation and that each PitB will harbor a second somatic mutation in DICER1. Lymphocyte or saliva DNA samples ascertained from ten infants with PitB were screened and nine were found to harbor a heterozygous germ-line DICER1 mutation. We identified additional DICER1 mutations in nine of ten tested PitB tumor samples, eight of which were confirmed to be somatic in origin. Seven of these mutations occurred within the RNase IIIb catalytic domain, a domain essential to the generation of 5p miRNAs from the 5' arm of miRNA-precursors. Germ-line DICER1 mutations are a major contributor to PitB. Second somatic DICER1 "hits" occurring within the RNase IIIb domain also appear to be critical in PitB pathogenesis
Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV
Superconducting transition-edge sensor (TES) microcalorimeters have great
utility in x-ray applications owing to their high energy resolution, good
collecting efficiency and the feasibility of being multiplexed into large
arrays. In this work, we develop hard x-ray TESs to measure the absolute
energies of muonic-argon (-Ar) transition lines around 44 keV and 20 keV.
TESs with sidecar absorbers of different heat capacities were fabricated and
characterized for their energy resolution and calibration uncertainty. We
achieved ~ 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV
energy resolution at 17.5 keV
Measurement of the cross-section and charge asymmetry of bosons produced in proton-proton collisions at TeV with the ATLAS detector
This paper presents measurements of the and cross-sections and the associated charge asymmetry as a
function of the absolute pseudorapidity of the decay muon. The data were
collected in proton--proton collisions at a centre-of-mass energy of 8 TeV with
the ATLAS experiment at the LHC and correspond to a total integrated luminosity
of 20.2~\mbox{fb^{-1}}. The precision of the cross-section measurements
varies between 0.8% to 1.5% as a function of the pseudorapidity, excluding the
1.9% uncertainty on the integrated luminosity. The charge asymmetry is measured
with an uncertainty between 0.002 and 0.003. The results are compared with
predictions based on next-to-next-to-leading-order calculations with various
parton distribution functions and have the sensitivity to discriminate between
them.Comment: 38 pages in total, author list starting page 22, 5 figures, 4 tables,
submitted to EPJC. All figures including auxiliary figures are available at
https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/STDM-2017-13
Search for chargino-neutralino production with mass splittings near the electroweak scale in three-lepton final states in √s=13 TeV pp collisions with the ATLAS detector
A search for supersymmetry through the pair production of electroweakinos with mass splittings near the electroweak scale and decaying via on-shell W and Z bosons is presented for a three-lepton final state. The analyzed proton-proton collision data taken at a center-of-mass energy of √s=13 TeV were collected between 2015 and 2018 by the ATLAS experiment at the Large Hadron Collider, corresponding to an integrated luminosity of 139 fb−1. A search, emulating the recursive jigsaw reconstruction technique with easily reproducible laboratory-frame variables, is performed. The two excesses observed in the 2015–2016 data recursive jigsaw analysis in the low-mass three-lepton phase space are reproduced. Results with the full data set are in agreement with the Standard Model expectations. They are interpreted to set exclusion limits at the 95% confidence level on simplified models of chargino-neutralino pair production for masses up to 345 GeV
Search for direct stau production in events with two hadronic tau-leptons in root s=13 TeV pp collisions with the ATLAS detector
A search for the direct production of the supersymmetric partners ofτ-leptons (staus) in final stateswith two hadronically decayingτ-leptons is presented. The analysis uses a dataset of pp collisions corresponding to an integrated luminosity of139fb−1, recorded with the ATLAS detector at the LargeHadron Collider at a center-of-mass energy of 13 TeV. No significant deviation from the expected StandardModel background is observed. Limits are derived in scenarios of direct production of stau pairs with eachstau decaying into the stable lightest neutralino and oneτ-lepton in simplified models where the two staumass eigenstates are degenerate. Stau masses from 120 GeV to 390 GeV are excluded at 95% confidencelevel for a massless lightest neutralino
A Tabletop X-Ray Tomography Instrument for Nanometer-Scale Imaging: Integration of a Scanning Electron Microscope with a Transition-Edge Sensor Spectrometer
X-ray nanotomography is a powerful tool for the characterization of nanoscale
materials and structures, but is difficult to implement due to competing
requirements on X-ray flux and spot size. Due to this constraint,
state-of-the-art nanotomography is predominantly performed at large synchrotron
facilities. Compact X-ray nanotomography tools operated in standard analysis
laboratories exist, but are limited by X-ray optics and destructive sample
preparation techniques. We present a laboratory-scale nanotomography instrument
that achieves nanoscale spatial resolution while changing the limitations of
conventional tomography tools. The instrument combines the electron beam of a
scanning electron microscope (SEM) with the precise, broadband X-ray detection
of a superconducting transition-edge sensor (TES) microcalorimeter. The
electron beam generates a highly focused X-ray spot in a metal target, while
the TES spectrometer isolates target photons with high signal-to-noise. This
combination of a focused X-ray spot, energy-resolved X-ray detection, and
unique system geometry enable nanoscale, element-specific X-ray imaging in a
compact footprint. The proof-of-concept for this approach to X-ray
nanotomography is demonstrated by imaging 160 nm features in three dimensions
in a Cu-SiO2 integrated circuit, and a path towards finer resolution and
enhanced imaging capabilities is discussed.Comment: The following article has been submitted to Physical Review Applie
A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray
We report on the 1,000-element transition-edge sensor (TES) x-ray
spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT).
TOMCAT combines a high spatial resolution scanning electron microscope (SEM)
with a highly efficient and pixelated TES spectrometer to reconstruct
three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel
prototype spectrometer was recently used to reconstruct ICs at the 130 nm
technology node, but to increase imaging speed to more practical levels, the
detector efficiency needs to be improved. For this reason, we are building a
spectrometer that will eventually contain 3,000 TES microcalorimeters read out
with microwave superconducting quantum interference device (SQUID)
multiplexing, and we currently have commissioned a 1,000 TES subarray. This
still represents a significant improvement from the 240-pixel system and allows
us to begin characterizing the full spectrometer performance. Of the 992
maximimum available readout channels, we have yielded 818 devices, representing
the largest number of TES x-ray microcalorimeters simultaneously read out to
date. These microcalorimeters have been optimized for pulse speed rather than
purely energy resolution, and we measure a FWHM energy resolution of 14 eV at
the 8.0 keV Cu K line.Comment: 5 pages, 4 figures, submitted to IEEE Transactions on Applied
Superconductivit
- …