530 research outputs found

    Effect of footwear type on biomechanical risk factors for knee osteoarthritis

    Get PDF
    Background: Regular walking in different types of footwear may increase the mediolateral shear force, knee adduction moment, or vertical ground-reaction forces that could increase the risk of early development of knee osteoarthritis (OA). Purpose: To compare kinematic and kinetic parameters that could affect the development of knee OA in 3 footwear conditions. Study design: Controlled laboratory study. Methods: A total of 40 asymptomatic participants performed walking trials in the laboratory at self-selected walking speeds under barefoot (BF), minimalistic (MF), and neutral (NF) footwear conditions. Knee joint parameters were described using discrete point values, and continuous curves were evaluated using statistical parametric mapping. A 3 × 1 repeated-measures analysis of variance was used to determine the main effect of footwear for both discrete and continuous data. To compare differences between footwear conditions, a post hoc paired t test was used. Results: Discrete point analyses showed a significantly greater knee power in NF compared with MF and BF in the weight absorption phase (P < .001 for both). Statistical parametric mapping analysis indicated a significantly greater knee angle in the sagittal plane at the end of the propulsive phase in BF compared with NF and MF (P = .043). Knee joint moment was significantly greater in the propulsive phase for the sagittal (P = .038) and frontal planes (P = .035) in BF compared with NF and MF and in the absorption phase in the sagittal plane (P = .034) in BF compared with MF and NF. A significant main effect of footwear was found for anteroposterior (propulsion, ↑MF, NF, ↓BF [P = .008]; absorption, ↑BF, MF, ↓NF [P = .001]), mediolateral (propulsion, ↑MF, NF, ↓BF [P = .005]; absorption, ↑NF, MF, ↓BF [P = .044]), and vertical (propulsion, ↑NF, BF, ↓MF [P = .001]; absorption, ↑MF, BF, ↓NF [P < .001]) ground-reaction forces. Knee power showed a significant main effect of footwear (absorption, ↑NF, MF, ↓BF [P = .015]; propulsion, ↑MF, NF, ↓BF [P = .039]). Conclusion: Walking in MF without sufficient accommodation affected kinetic and kinematic parameters and could increase the risk of early development of knee OA

    Ultrasonographic Assessment of the Normal Femoral Articular Cartilage of the Knee Joint: Comparison with 3D MRI

    Get PDF
    ObjectiveUltrasonography (US) has a promising role in evaluating the knee joint, but capability to visualize the femoral articular cartilage needs systematic evaluation. We measured the extent of this acoustic window by comparing standardized US images with the corresponding MRI views of the femoral cartilage.DesignTen healthy volunteers without knee pathology underwent systematic US and MRI evaluation of both knees. The femoral cartilage was assessed on the oblique transverse axial plane with US and with 3D MRI. The acoustic window on US was compared to the corresponding views of the femoral sulcus and both condyles on MRI. The mean imaging coverage of the femoral cartilage and the cartilage thickness measurements on US and MRI were compared.ResultsMean imaging coverage of the cartilage of the medial femoral condyle was 66% (range 54%–80%) and on the lateral femoral condyle 37% (range 25%–51%) compared with MRI. Mean cartilage thickness measurement in the femoral sulcus was 3.17 mm with US and 3.61 mm with MRI (14.0% difference). The corresponding measurements in the medial femoral condyle were 1.95 mm with US and 2.35 mm with MRI (21.0% difference), and in the lateral femoral condyle, they were 2.17 mm and 2.73 mm (25.6% difference), respectively.ConclusionTwo-thirds of the articular cartilage of the medial femoral condyle, and one-third in the lateral femoral condyle, can be assessed with US. The cartilage thickness measurements seem to be underestimated by US. These results show promise for the evaluation of the weight-bearing cartilage of the medial femoral condyle with US.</p

    BIOMECHANICS IN THE 4HAIE STUDY: AIR POLLUTION AND MUSCULOSKELETAL HEALTH - AN UPDATE

    Get PDF
    The overall purpose of the 4HAIE study was to assess the influence of the interaction between air pollution and biomechanical, physiological and psychosocial factors on the incidence of injuries, health and well-being. A total of 1,500 active runners and inactive controls aged 18-65 will be recruited. Herein, we describe the biomechanical study design with data examples to investigate musculoskeletal and neuro-mechanics health in different air quality regions

    2019 ESC/EAS guidelines for the management of dyslipidaemias : Lipid modification to reduce cardiovascular risk

    Get PDF
    Correction: Volume: 292 Pages: 160-162 DOI: 10.1016/j.atherosclerosis.2019.11.020 Published: JAN 2020Peer reviewe

    Azimuthal anisotropy of charged jet production in root s(NN)=2.76 TeV Pb-Pb collisions

    Get PDF
    We present measurements of the azimuthal dependence of charged jet production in central and semi-central root s(NN) = 2.76 TeV Pb-Pb collisions with respect to the second harmonic event plane, quantified as nu(ch)(2) (jet). Jet finding is performed employing the anti-k(T) algorithm with a resolution parameter R = 0.2 using charged tracks from the ALICE tracking system. The contribution of the azimuthal anisotropy of the underlying event is taken into account event-by-event. The remaining (statistical) region-to-region fluctuations are removed on an ensemble basis by unfolding the jet spectra for different event plane orientations independently. Significant non-zero nu(ch)(2) (jet) is observed in semi-central collisions (30-50% centrality) for 20 <p(T)(ch) (jet) <90 GeV/c. The azimuthal dependence of the charged jet production is similar to the dependence observed for jets comprising both charged and neutral fragments, and compatible with measurements of the nu(2) of single charged particles at high p(T). Good agreement between the data and predictions from JEWEL, an event generator simulating parton shower evolution in the presence of a dense QCD medium, is found in semi-central collisions. (C) 2015 CERN for the benefit of the ALICE Collaboration. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).Peer reviewe

    Production of He-4 and (4) in Pb-Pb collisions at root(NN)-N-S=2.76 TeV at the LHC

    Get PDF
    Results on the production of He-4 and (4) nuclei in Pb-Pb collisions at root(NN)-N-S = 2.76 TeV in the rapidity range vertical bar y vertical bar <1, using the ALICE detector, are presented in this paper. The rapidity densities corresponding to 0-10% central events are found to be dN/dy4(He) = (0.8 +/- 0.4 (stat) +/- 0.3 (syst)) x 10(-6) and dN/dy4 = (1.1 +/- 0.4 (stat) +/- 0.2 (syst)) x 10(-6), respectively. This is in agreement with the statistical thermal model expectation assuming the same chemical freeze-out temperature (T-chem = 156 MeV) as for light hadrons. The measured ratio of (4)/He-4 is 1.4 +/- 0.8 (stat) +/- 0.5 (syst). (C) 2018 Published by Elsevier B.V.Peer reviewe

    Forward-central two-particle correlations in p-Pb collisions at root s(NN)=5.02 TeV

    Get PDF
    Two-particle angular correlations between trigger particles in the forward pseudorapidity range (2.5 2GeV/c. (C) 2015 CERN for the benefit of the ALICE Collaboration. Published by Elsevier B. V.Peer reviewe

    Event-shape engineering for inclusive spectra and elliptic flow in Pb-Pb collisions at root(NN)-N-S=2.76 TeV

    Get PDF
    Peer reviewe
    corecore