95 research outputs found

    Infected thrombophlebitis of the right internal jugular vein

    Get PDF

    Clinical Relevance of Parafoveal Intercapillary Spaces and Foveal Avascular Zone in Diabetic Retinopathy Without Macular Edema

    Get PDF
    Purpose: To investigate the clinical significance of intercapillary spaces on swept source optical coherence tomography angiography images in diabetic retinopathy. Methods: We retrospectively reviewed 110 eyes of 110 patients suffering from diabetic retinopathy without macular edema for whom 3 × 3 mm swept source optical coherence tomography angiography images centered on the fovea were obtained. Automatic image processing of the superficial slab images allowed us to define the areas encircled by retinal vessels as intercapillary spaces within the central 2-mm circle. We evaluated how the quantitative parameters of intercapillary spaces are associated with logMAR and feasible to diagnose diabetic macular ischemia. Results: Total counts (ρ = −0.419; P < 0.001) rather than morphologic parameters of the intercapillary spaces showed a significant correlation with logMAR. There were individual levels of correlations between logMAR and counts of intercapillary spaces in individual sectors. In particular, the summed numbers of the spaces in three highly significant sectors were more significantly associated with logMAR (ρ = −0.515; P < 0.001). Multivariate analyses confirmed that the number of the intercapillary spaces (β = −0.266; P = 0.016) and foveal avascular zone area (β = 0.227; P = 0.042) were related to logMAR. The clustering using the foveal avascular zone area and the number of intercapillary spaces revealed two major clusters; one had fewer intercapillary spaces (P < 0.001) and poorer logMAR (P < 0.001) than the other, with a wide range of the foveal avascular zone area. Conclusions: Decreased intercapillary spaces contribute to visual impairment in diabetic retinopathy and suggest one possible criterion of objective diagnosis of diabetic macular ischemia

    The intercapillary space spectrum as a marker of diabetic retinopathy severity on optical coherence tomography angiography

    Get PDF
    Microcirculatory disturbance plays a pivotal role in the pathogenesis in diabetic retinopathy (DR). We retrospectively quantified the total counts and morphological features of intercapillary spaces, i.e., intercapillary areas and nonperfusion areas (NPAs), on swept-source optical coherence tomography angiography (SS-OCTA) images and to evaluate their associations with DR severity grades. We acquired 3 × 3 mm OCTA images in 75 eyes of 62 diabetic patients and 22 eyes of 22 nondiabetic subjects. In the en-face superficial images within the central 2 mm, the areas enclosed by retinal vessels were automatically detected. Their total numbers decreased in some eyes with no apparent retinopathy and most eyes with DR, which allowed us to discriminate diabetic subjects from nondiabetic subjects [area under the receiver operating characteristic curve (AUC) = 0.907]. The areas and area/perimeter ratios continuously increased in DR, indicating a continuum between healthy intercapillary areas and NPAs. The number of intercapillary spaces with a high area/perimeter ratio increased according to DR severity, which showed modest performance in discriminating moderate NPDR or higher grades (AUC = 0.868). These quantified parameters of intercapillary spaces can feasibly be used for the early detection of microcirculatory impairment and the diagnosis of referable DR

    Clinically Significant Nonperfusion Areas on Widefield OCT Angiography in Diabetic Retinopathy

    Get PDF
    [Purpose] To investigate the distribution of clinically significant nonperfusion areas (NPAs) on widefield OCT angiography (OCTA) images in patients with diabetes. [Design] Prospective, cross-sectional, observational study. [Participants] One hundred and forty-four eyes of 114 patients with diabetes. [Methods] Nominal 20 × 23 mm OCTA images were obtained using a swept-source OCTA device (Xephilio OCT-S1), followed by the creation of en face images 20-mm (1614 pixels) in diameter centering on the fovea. The nonperfusion squares (NPSs) were defined as the 10 × 10 pixel squares without retinal vessels, and the ratio of eyes with the NPSs to all eyes in each square was referred to as the NPS ratio. The areas with probabilistic differences (APD) for proliferative diabetic retinopathy (PDR) and nonproliferative diabetic retinopathy (NPDR) (APD[PDR] and APD[NPDR]) were defined as sets of squares with higher NPS ratios in eyes with PDR and NPDR, respectively. The P ratio (NPSs within APD[PDR] but not APD[NPDR]/all NPSs) was also calculated. [Main Outcome Measures] The probabilistic distribution of the NPSs and the association with diabetic retinopathy (DR) severity. [Results] The NPSs developed randomly in eyes with mild and moderate NPDR and were more prevalent in the extramacular areas and the temporal quadrant in eyes with severe NPDR and PDR. The APD(PDR) was distributed mainly in the extramacular areas, sparing the areas around the vascular arcades and radially peripapillary capillaries. The APD(PDR) contained retinal neovascularization more frequently than the non-APD(PDR) (P = 0.023). The P ratio was higher in eyes with PDR than in those with NPDR (P < 0.001). The multivariate analysis designated the P ratio (odds ratio, 8.293 × 107; 95% confidence interval, 6.529 × 102–1.053 × 1013; P = 0.002) and the total NPSs (odds ratio, 1.002; 95% confidence interval, 1.001–1.003; P < 0.001) as independent risk factors of PDR. Most eyes with NPDR and 4-2-1 rule findings of DR severity had higher P ratios but not necessarily greater NPS numbers. [Conclusions] The APD(PDR) is uniquely distributed on widefield OCTA images, and the NPA location patterns are associated with DR severity, independent of the entire area of NPAs. [Financial Disclosure(s)] Proprietary or commercial disclosure may be found after the references

    Effectiveness of Preradiosurgical Embolization with NBCA for Arteriovenous Malformations - Retrospective Outcome Analysis in a Japanese Registry of 73 Patients (J-REAL study)

    Get PDF
    PurposeRecent reports have posed doubts about the effect of preradiosurgical embolization in brain arteriovenous malformation (AVM) because it makes the planning of stereotactic radiosurgery (SRS) difficult and has the risk of recanalization out of the target. We investigated whether the performance and quality of embolization may influence the success of SRS based on a retrospective case cohort study.Materials and MethodsSeventy-three patients who underwent embolization followed by SRS between 2003 and 2012 in eight institutes with neurointerventionists were considered. They were divided into the following two groups at 3 years of follow up after the final SRS: “successful occlusion group” (S group), with radiologically complete occlusion of AVM; and “non-successful occlusion group” (N group) with persistent remnant nidus or abnormal vascular networks. Patient background, AVM profile, embolization performance grade and complications were compared in each group. The quality of embolization was evaluated with the new grading system: embolization performance grade (E grade), specializing the achievement of nidus embolization. E grade A was defined as sufficient nidus embolization with more than half of the total number of feeders achieving nidus penetration. E grade B was defined as less than half achievement of nidus embolization, and E grade C was defines as failure to perform nidus embolization.ResultsForty-three patients were included in the S group, and 29 patients were included in the N group. The size and Spetzler-Martin grade of AVM and the rate of diffuse type was higher in the N group without statistical significance. The embolization performance level according to E grade indicated a significantly higher rate of successful embolization with more than 50% of nidus penetration in the S group (P<0.001). This difference was also confirmed in the subanalysis for limited cases, excluding smaller AVMs with complete occlusion with SRS alone (P=0.001).ConclusionThe cause of the unsuccessful result of post-embolization SRS might be the large, diffuse angioarchitecture, but proper embolization with a high rate of nidus penetration to avoid recanalization is more important. Effective embolization is essential to contribute to and promote the effect of radiosurgery

    サイセンタン ノ サンジゲン イメージング システム : シンゾウ ケッカン ゲカ ニオケル Virtual Reality ギジュツ ノ ユウヨウセイ

    Get PDF
    滋賀医科大学心臓血管外科では医療用画像を三次元構築し、臓器を立体表示するVirtual Reality (VR) 技術を用いて心臓血管系の3D解析研究を進めている。VRでは臓器の内腔を可視化することができ、また3D構築した画像に直接介入し、従来の2D解析では評価困難であった複雑な構造も術者の視点で直観的に計測できるという利点がある。あらゆる医療画像データを三次元化し, かつ直感的な立体計測が可能なVR技術は, これまでの診断精度を上回る形態学的な情報を臨床医に提示し得ると考えられる。特に外科医にとって有用な手術支援VR画像は, 難易度が高い手術の治療成績を向上させる可能性が高い。Adequate preoperative planning may facilitate successful procedures in cardiovascular surgery. We have newly developed a system the Vesalius 3D suite, combining three-dimensional (3D) image-processing software with an optic-tracking spatial navigation, allowing quick, accessible 3D image interpretation for virtual reality (VR) exploration and measurement of complex anatomy. In this review, we present a novel method of virtual imaging analysis for preoperative planning and simulation in cardiovascular operation using this 3D-VR system. Based on unimodal or multimodal medical imaging data, DICOM data sets can be reconstructed for 3D visualization. Virtually reconstructed images can be viewed on stereoscopic 3D display, revealing each patient’s specific anatomy and the internal structures in exquisite detail. Highly accessible 3D interpretation promptly permits precise and intuitive measurements of repair-relevant anatomical parameters including geometrically complex shapes. This technology may promote understanding of form and function in the cardiovascular system, and facilitate operative procedures in more challenging cases. Furthermore, this system can be especially valuable for any surgeon to gain experience in practicing for rarely-performed procedures or uncommon patient-specific preoperative surgical simulations

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Search for single production of vector-like quarks decaying into Wb in pp collisions at s=8\sqrt{s} = 8 TeV with the ATLAS detector

    Get PDF

    Measurements of top-quark pair differential cross-sections in the eμe\mu channel in pppp collisions at s=13\sqrt{s} = 13 TeV using the ATLAS detector

    Get PDF

    Measurement of the W boson polarisation in ttˉt\bar{t} events from pp collisions at s\sqrt{s} = 8 TeV in the lepton + jets channel with ATLAS

    Get PDF
    corecore