161 research outputs found

    The selective COX-2 inhibitor etoricoxib reduces acute inflammatory markers in a model of neurogenic laryngitis but loses its efficacy with prolonged treatment

    Get PDF
    The selective COX-2 inhibitor Etoricoxib reduces acute inflammatory markers in a model of neurogenic laryngitis but loses its efficacy with prolonged treatment.OBJECTIVE: A randomised experimental study was used to evaluate the therapeutic effect of a selective cyclooxygenase-2 (COX-2) inhibitor in neurogenic laryngitis. MATERIALS AND METHODS: Male Wistar Han rats were subjected to the nasogastric intubation model (NGI) of laryngitis for 1 and 2 weeks. The NGI animals were divided into three groups: (1) treated with COX-2 inhibitor Etoricoxib, (2) vehicle and (3) non-intubated animals. A fourth group of animals was submitted to NGI only. Laryngeal sections were immunostained for substance P (SP) and calcitonin gene-related peptide (CGRP) fibre-immunoreactivity (IR) and quantification of COX-2 positive cells through stereological analysis. The expression of COX-2, interleukins IL-1beta, IL-6, IL-10 and tumour necrosis factor-alpha (TNF-alpha) was determined by quantitative real time QRT-PCR. TREATMENT: Etoricoxib (6 mg/kg/day) was prepared in 0.9% sterile saline with 5% glucose (vehicle) and administered daily during 1 or 2 weeks. RESULTS: Treatment for 1 week with Etoricoxib attenuated the CGRP-IR fibre depletion, the COX-2-IR increased cell number and the TNF-alpha and COX-2 mRNA increased levels induced by NGI. Two weeks of treatment had no beneficial effect. CONCLUSIONS: Etoricoxib is effective in neurogenic laryngitis for limited periods of administration, indicating that selective COX-2 inhibitors should be evaluated in the future.This study was supported by Fundacao Calouste Gulbenkian Project No 74551 and Fundacao Grunenthal (Portugal)

    Task force for the diagnosis of thrombotic microangiopathy / Força-tarefa para o diagnóstico de microangiopatia trombótica

    Get PDF
    Background: Thrombotic microangiopathy triggers microangiopathic hemolytic anemia, thrombocytopenia, and organic injuries. It is a rare and serious condition that demands specific approaches and strategies to recognize it promptly, especially in critically ill patients. The task force could be an effective model. Methods: An evaluative study of the impact of a task force in establishing a routine for the diagnosis of TMA in ICUs. A standard flowchart was used for 90 consecutive days and a low platelet count was the driver for the collection of epidemiological and laboratory data. Suspicion of typical HUS was proven after analyzing haptoglobin, LDH, creatinine, ADAMTS-13 enzyme, and Shiga toxin levels.  Meetings were also held with ICU personnel and the self-explanatory flowchart was fine tuned. Results: There were 490 patients (55.9% male and 44.1% female) aged 59.5 ± 21.13 years. Forty-two percent of patients in the sample had thrombocytopenia. Out of the 42 patients, five (1.02%) had TTP, three (0.6%) were presumed to have atypical HUS, and none had typical HUS. The task force remained in touch with researchers to assess diagnoses and three other suspected cases of atypical HUS underwent specific treatment.Discussion: Only 1.62% of the sampled patients had TMA. Despite its complexity, the task force model is useful in situations in which higher technology is the norm.  Conclusion: The use of a task force has proven to be effective in establishing a diagnostic practice for a health condition deemed rare or exceedingly rare

    Mental health and burnout syndrome among postgraduate students in medical and multidisciplinary residencies during the COVID-19 pandemic in Brazil : protocol for a prospective cohort study

    Get PDF
    Background: The COVID-19 pandemic has led to high levels of physical, psychological, and social stress among health care professionals, including postgraduate students in medical and multidisciplinary residencies. This stress is associated with the intense fear of occupational exposure to SARS-CoV-2, the virus known to cause COVID-19. These professionals are at risk of developing physical and mental illnesses not only due to the infection but also due to prolonged exposure to multidimensional stress and continued work overload. Objective: This study aims to evaluate the prevalence of symptoms suggestive of mental disorders and burnout syndrome and determine the risk factors for burnout among postgraduate students in medical and multidisciplinary residencies in Brazil during the COVID-19 pandemic. Methods: For this prospective cohort study with parallel groups, participants were recruited between July and September 2020 to achieve a sample size of at least 1144 participants. Research instruments such as Depression, Anxiety, and Stress Scale; Patient Health Questionnaire; Brief Resilient Coping Scale; and Oldenburg Burnout Inventory will be used to collect data. Data will be collected in 2 waves: the first wave will include data related to sample characterization and psychosocial evaluation, and the second wave will be launched 12 weeks later and will include an evaluation of the incidence of burnout as well as correlations with the potential predictive factors collected in the first wave. Additionally, we will collect data regarding participants’ withdrawal from work. Results: The recruitment took place from July 29 to September 5, 2020. Data analyses for this phase is already in progress. The second phase of the study is also in progress. The final data collection began on December 1, 2020, and it will be completed by December 31, 2020. Conclusions: We believe the findings of this study will help evaluate the impact of the COVID-19 pandemic on the mental health conditions of health professionals in Brazil as well as contribute to the planning and implementation of appropriate measures that can alleviate these mental health challenges. International Registered Report Identifier (IRRID): DERR1-10.2196/2429

    Consistent patterns of common species across tropical tree communities

    Get PDF
    Trees structure the Earth’s most biodiverse ecosystem, tropical forests. The vast number of tree species presents a formidable challenge to understanding these forests, including their response to environmental change, as very little is known about most tropical tree species. A focus on the common species may circumvent this challenge. Here we investigate abundance patterns of common tree species using inventory data on 1,003,805 trees with trunk diameters of at least 10 cm across 1,568 locations1,2,3,4,5,6 in closed-canopy, structurally intact old-growth tropical forests in Africa, Amazonia and Southeast Asia. We estimate that 2.2%, 2.2% and 2.3% of species comprise 50% of the tropical trees in these regions, respectively. Extrapolating across all closed-canopy tropical forests, we estimate that just 1,053 species comprise half of Earth’s 800 billion tropical trees with trunk diameters of at least 10 cm. Despite differing biogeographic, climatic and anthropogenic histories7, we find notably consistent patterns of common species and species abundance distributions across the continents. This suggests that fundamental mechanisms of tree community assembly may apply to all tropical forests. Resampling analyses show that the most common species are likely to belong to a manageable list of known species, enabling targeted efforts to understand their ecology. Although they do not detract from the importance of rare species, our results open new opportunities to understand the world’s most diverse forests, including modelling their response to environmental change, by focusing on the common species that constitute the majority of their trees.Publisher PDFPeer reviewe

    Long-range angular correlations on the near and away side in p–Pb collisions at

    Get PDF

    Forward-central two-particle correlations in p-Pb collisions at root s(NN)=5.02 TeV

    Get PDF
    Two-particle angular correlations between trigger particles in the forward pseudorapidity range (2.5 2GeV/c. (C) 2015 CERN for the benefit of the ALICE Collaboration. Published by Elsevier B. V.Peer reviewe

    Event-shape engineering for inclusive spectra and elliptic flow in Pb-Pb collisions at root(NN)-N-S=2.76 TeV

    Get PDF
    Peer reviewe

    Educomunicação e suas áreas de intervenção: Novos paradigmas para o diálogo intercultural

    Get PDF
    oai:omp.abpeducom.org.br:publicationFormat/1O material aqui divulgado representa, em essência, a contribuição do VII Encontro Brasileiro de Educomunicação ao V Global MIL Week, da UNESCO, ocorrido na ECA/USP, entre 3 e 5 de novembro de 2016. Estamos diante de um conjunto de 104 papers executivos, com uma média de entre 7 e 10 páginas, cada um. Com este rico e abundante material, chegamos ao sétimo e-book publicado pela ABPEducom, em seus seis primeiros anos de existência. A especificidade desta obra é a de trazer as “Áreas de Intervenção” do campo da Educomunicação, colocando-as a serviço de uma meta essencial ao agir educomunicativo: o diálogo intercultural, trabalhado na linha do tema geral do evento internacional: Media and Information Literacy: New Paradigms for Intercultural Dialogue

    Diretrizes Brasileiras de Medidas da Pressão Arterial Dentro e Fora do Consultório – 2023

    Get PDF
    Hypertension is one of the primary modifiable risk factors for morbidity and mortality worldwide, being a major risk factor for coronary artery disease, stroke, and kidney failure. Furthermore, it is highly prevalent, affecting more than one-third of the global population. Blood pressure measurement is a MANDATORY procedure in any medical care setting and is carried out by various healthcare professionals. However, it is still commonly performed without the necessary technical care. Since the diagnosis relies on blood pressure measurement, it is clear how important it is to handle the techniques, methods, and equipment used in its execution with care. It should be emphasized that once the diagnosis is made, all short-term, medium-term, and long-term investigations and treatments are based on the results of blood pressure measurement. Therefore, improper techniques and/or equipment can lead to incorrect diagnoses, either underestimating or overestimating values, resulting in inappropriate actions and significant health and economic losses for individuals and nations. Once the correct diagnosis is made, as knowledge of the importance of proper treatment advances, with the adoption of more detailed normal values and careful treatment objectives towards achieving stricter blood pressure goals, the importance of precision in blood pressure measurement is also reinforced. Blood pressure measurement (described below) is usually performed using the traditional method, the so-called casual or office measurement. Over time, alternatives have been added to it, through the use of semi-automatic or automatic devices by the patients themselves, in waiting rooms or outside the office, in their own homes, or in public spaces. A step further was taken with the use of semi-automatic devices equipped with memory that allow sequential measurements outside the office (ABPM; or HBPM) and other automatic devices that allow programmed measurements over longer periods (HBPM). Some aspects of blood pressure measurement can interfere with obtaining reliable results and, consequently, cause harm in decision-making. These include the importance of using average values, the variation in blood pressure during the day, and short-term variability. These aspects have encouraged the performance of a greater number of measurements in various situations, and different guidelines have advocated the use of equipment that promotes these actions. Devices that perform HBPM or ABPM, which, in addition to allowing greater precision, when used together, detect white coat hypertension (WCH), masked hypertension (MH), sleep blood pressure alterations, and resistant hypertension (RHT) (defined in Chapter 2 of this guideline), are gaining more and more importance. Taking these details into account, we must emphasize that information related to diagnosis, classification, and goal setting is still based on office blood pressure measurement, and for this reason, all attention must be given to the proper execution of this procedure.La hipertensión arterial (HTA) es uno de los principales factores de riesgo modificables para la morbilidad y mortalidad en todo el mundo, siendo uno de los mayores factores de riesgo para la enfermedad de las arterias coronarias, el accidente cerebrovascular (ACV) y la insuficiencia renal. Además, es altamente prevalente y afecta a más de un tercio de la población mundial. La medición de la presión arterial (PA) es un procedimiento OBLIGATORIO en cualquier atención médica o realizado por diferentes profesionales de la salud. Sin embargo, todavía se realiza comúnmente sin los cuidados técnicos necesarios. Dado que el diagnóstico se basa en la medición de la PA, es claro el cuidado que debe haber con las técnicas, los métodos y los equipos utilizados en su realización. Debemos enfatizar que una vez realizado el diagnóstico, todas las investigaciones y tratamientos a corto, mediano y largo plazo se basan en los resultados de la medición de la PA. Por lo tanto, las técnicas y/o equipos inadecuados pueden llevar a diagnósticos incorrectos, subestimando o sobreestimando valores y resultando en conductas inadecuadas y pérdidas significativas para la salud y la economía de las personas y las naciones. Una vez realizado el diagnóstico correcto, a medida que avanza el conocimiento sobre la importancia del tratamiento adecuado, con la adopción de valores de normalidad más detallados y objetivos de tratamiento más cuidadosos hacia metas de PA más estrictas, también se refuerza la importancia de la precisión en la medición de la PA. La medición de la PA (descrita a continuación) generalmente se realiza mediante el método tradicional, la llamada medición casual o de consultorio. Con el tiempo, se han agregado alternativas a través del uso de dispositivos semiautomáticos o automáticos por parte del propio paciente, en salas de espera o fuera del consultorio, en su propia residencia o en espacios públicos. Se dio un paso más con el uso de dispositivos semiautomáticos equipados con memoria que permiten mediciones secuenciales fuera del consultorio (AMPA; o MRPA) y otros automáticos que permiten mediciones programadas durante períodos más largos (MAPA). Algunos aspectos en la medición de la PA pueden interferir en la obtención de resultados confiables y, en consecuencia, causar daños en las decisiones a tomar. Estos incluyen la importancia de usar valores promedio, la variación de la PA durante el día y la variabilidad a corto plazo. Estos aspectos han alentado la realización de un mayor número de mediciones en diversas situaciones, y diferentes pautas han abogado por el uso de equipos que promuevan estas acciones. Los dispositivos que realizan MRPA o MAPA, que además de permitir una mayor precisión, cuando se usan juntos, detectan la hipertensión de bata blanca (HBB), la hipertensión enmascarada (HM), las alteraciones de la PA durante el sueño y la hipertensión resistente (HR) (definida en el Capítulo 2 de esta guía), están ganando cada vez más importancia. Teniendo en cuenta estos detalles, debemos enfatizar que la información relacionada con el diagnóstico, la clasificación y el establecimiento de objetivos todavía se basa en la medición de la presión arterial en el consultorio, y por esta razón, se debe prestar toda la atención a la ejecución adecuada de este procedimiento.A hipertensão arterial (HA) é um dos principais fatores de risco modificáveis para morbidade e mortalidade em todo o mundo, sendo um dos maiores fatores de risco para doença arterial coronária, acidente vascular cerebral (AVC) e insuficiência renal. Além disso, é altamente prevalente e atinge mais de um terço da população mundial. A medida da PA é procedimento OBRIGATÓRIO em qualquer atendimento médico ou realizado por diferentes profissionais de saúde. Contudo, ainda é comumente realizada sem os cuidados técnicos necessários. Como o diagnóstico se baseia na medida da PA, fica claro o cuidado que deve haver com as técnicas, os métodos e os equipamentos utilizados na sua realização. Deve-se reforçar que, feito o diagnóstico, toda a investigação e os tratamentos de curto, médio e longo prazos são feitos com base nos resultados da medida da PA. Assim, técnicas e/ou equipamentos inadequados podem levar a diagnósticos incorretos, tanto subestimando quanto superestimando valores e levando a condutas inadequadas e grandes prejuízos à saúde e à economia das pessoas e das nações. Uma vez feito o diagnóstico correto, na medida em que avança o conhecimento da importância do tratamento adequado, com a adoção de valores de normalidade mais detalhados e com objetivos de tratamento mais cuidadosos no sentido do alcance de metas de PA mais rigorosas, fica também reforçada a importância da precisão na medida da PA. A medida da PA (descrita a seguir) é habitualmente feita pelo método tradicional, a assim chamada medida casual ou de consultório. Ao longo do tempo, foram agregadas alternativas a ela, mediante o uso de equipamentos semiautomáticos ou automáticos pelo próprio paciente, nas salas de espera ou fora do consultório, em sua própria residência ou em espaços públicos. Um passo adiante foi dado com o uso de equipamentos semiautomáticos providos de memória que permitem medidas sequenciais fora do consultório (AMPA; ou MRPA) e outros automáticos que permitem medidas programadas por períodos mais prolongados (MAPA). Alguns aspectos na medida da PA podem interferir na obtenção de resultados fidedignos e, consequentemente, causar prejuízo nas condutas a serem tomadas. Entre eles, estão: a importância de serem utilizados valores médios, a variação da PA durante o dia e a variabilidade a curto prazo. Esses aspectos têm estimulado a realização de maior número de medidas em diversas situações, e as diferentes diretrizes têm preconizado o uso de equipamentos que favoreçam essas ações. Ganham cada vez mais espaço os equipamentos que realizam MRPA ou MAPA, que, além de permitirem maior precisão, se empregados em conjunto, detectam a HA do avental branco (HAB), HA mascarada (HM), alterações da PA no sono e HA resistente (HAR) (definidos no Capítulo 2 desta diretriz). Resguardados esses detalhes, devemos ressaltar que as informações relacionadas a diagnóstico, classificação e estabelecimento de metas ainda são baseadas na medida da PA de consultório e, por esse motivo, toda a atenção deve ser dada à realização desse procedimento
    corecore