19 research outputs found

    Threshold for Synovial Cell Count and Neutrophil Differential in Diagnosis of Periprosthetic Knee Infection: A Multi-Institutional Study

    Get PDF
    Introduction: Synovial fl­uid analysis is an important tool in the work-up of suspected periprosthetic joint infection (PJI). Yet, there is confl­icting guidance for the analysis of synovial fl­uid aspiration, including a lack of uniform thresholds for white blood cell (WBC) count and neutrophil percentage (PMN%)1-3. Therefore, a multi-institutional study was undertaken to reassess these thresholds, compare preoperative versus intraoperative sample collection, and assess variation in results between institutions

    Search for high-mass diphoton resonances in proton-proton collisions at 13 TeV and combination with 8 TeV search

    Get PDF
    Peer reviewe

    Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries.

    Get PDF
    BACKGROUND: As global initiatives increase patient access to surgical treatments, there remains a need to understand the adverse effects of surgery and define appropriate levels of perioperative care. METHODS: We designed a prospective international 7-day cohort study of outcomes following elective adult inpatient surgery in 27 countries. The primary outcome was in-hospital complications. Secondary outcomes were death following a complication (failure to rescue) and death in hospital. Process measures were admission to critical care immediately after surgery or to treat a complication and duration of hospital stay. A single definition of critical care was used for all countries. RESULTS: A total of 474 hospitals in 19 high-, 7 middle- and 1 low-income country were included in the primary analysis. Data included 44 814 patients with a median hospital stay of 4 (range 2-7) days. A total of 7508 patients (16.8%) developed one or more postoperative complication and 207 died (0.5%). The overall mortality among patients who developed complications was 2.8%. Mortality following complications ranged from 2.4% for pulmonary embolism to 43.9% for cardiac arrest. A total of 4360 (9.7%) patients were admitted to a critical care unit as routine immediately after surgery, of whom 2198 (50.4%) developed a complication, with 105 (2.4%) deaths. A total of 1233 patients (16.4%) were admitted to a critical care unit to treat complications, with 119 (9.7%) deaths. Despite lower baseline risk, outcomes were similar in low- and middle-income compared with high-income countries. CONCLUSIONS: Poor patient outcomes are common after inpatient surgery. Global initiatives to increase access to surgical treatments should also address the need for safe perioperative care. STUDY REGISTRATION: ISRCTN5181700

    Search for a pseudoscalar boson decaying into a Z boson and the 125 GeV Higgs boson in ℓ+ℓ-bb final states

    Get PDF
    Results are reported on a search for decays of a pseudoscalar A boson into a Z boson and a light scalar h boson, where the Z boson decays into a pair of oppositely-charged electrons or muons, and the h boson decays into bb- The search is based on data from proton-proton collisions at a center-of-mass energy s=8 TeV collected with the CMS detector, corresponding to an integrated luminosity of 19.7 fb-1. The h boson is assumed to be the standard model-like Higgs boson with a mass of 125 GeV. With no evidence for signal, upper limits are obtained on the product of the production cross section and the branching fraction of the A boson in the Zh channel. Results are also interpreted in the context of two Higgs doublet models. © 2015

    Searches for heavy Higgs bosons in two-Higgs-doublet models and for t → c h decay using multilepton and diphoton final states in p p collisions at 8 TeV

    Get PDF
    Searches are presented for heavy scalar (H) and pseudoscalar (A) Higgs bosons posited in the two doublet model (2HDM) extensions of the standard model (SM). These searches are based on a data sample of pp collisions collected with the CMS experiment at the LHC at a center-of-mass energy of root s = 8 TeV and corresponding to an integrated luminosity of 19.5 fb(-1). The decays H - GT hh and A - GT Zh, where h denotes an SM-like Higgs boson, lead to events with three or more isolated charged leptons or with a photon pair accompanied by one or more isolated leptons. The search results are presented in terms of the H and A production cross sections times branching fractions and are further interpreted in terms of 2HDM parameters. We place 95% C.L. cross section upper limits of approximately 7 pb on sigma B for H - GT hh and 2 pb for A - GT Zh. Also presented are the results of a search for the rare decay of the top quark that results in a charm quark and an SM Higgs boson, t - GT ch, the existence of which would indicate a nonzero flavor-changing Yukawa coupling of the top quark to the Higgs boson. We place a 95% C.L. upper limit of 0.56% on B(t - GT ch)

    Are patients being evaluated for periprosthetic joint infection prior to referral to a tertiary care center?

    No full text
    Background: Patients with a painful or failed total joint arthroplasties should be evaluated for periprosthetic joint infection (PJI). The purpose of this study is to determine if patients referred to a tertiary care center had been evaluated for PJI according to the American Academy of Orthopaedic Surgeons (AAOS) clinical practice guidelines. Methods: One hundred thirteen patients with painful hip (43) or knee (70) arthroplasties were referred to a single provider by orthopaedic surgeons outside our practice between 2012 and 2014. We retrospectively evaluated the workup by referring physicians, including measurement of serum erythrocyte sedimentation rate and C-reactive protein, performance of a joint aspiration if these values were abnormal, and obtainment of synovial fluid white blood cell count, differential, and cultures. Results: Sixty-two of 113 patients (55%) did not have a workup that followed AAOS guidelines. Serum erythrocyte sedimentation rate and C-reactive protein were ordered for 64 of the 113 patients (57%). Of 25 patients with elevated inflammatory markers warranting aspiration, 15 (60%) had an aspiration attempted, with synovial fluid white blood cell, differential, and cultures obtained in 9 of 12 (75%) aspirations that yielded fluid. Of the 62 patients with an incomplete infection workup, 11 (18%) had a bone scan, 6 (10%) a computed tomography scan, and 3 (5%) a magnetic resonance imaging. Twelve of the 113 patients (11%) were ultimately diagnosed with PJI, with 5 undiagnosed prior to referral. Conclusions: The AAOS guidelines to evaluate for PJI are frequently not being followed. Improving awareness of these guidelines may avoid unnecessary and costly evaluations and delay in the diagnosis of PJI

    A classification-based approach to the patella in revision total knee arthroplasty

    No full text
    Background: There is a paucity of data to guide management of the patella in revision total knee arthroplasty (RTKA). The purpose of this study was to review our experience with patellar management in RTKA. Methods: We retrospectively reviewed 422 consecutive RTKAs at a minimum of 2 years (mean, 42 months). Patellar management was guided by a classification that considered stability, size, and position of the implanted patellar component, thickness/quality of remaining bone stock, and extensor mechanism competence. Results: Management in 304 aseptic revisions included retention of a well-fixed component in 212 (69.7%) and revision using an all-polyethylene component in 46 (15.1%). Patella-related complications included 5 extensor mechanism ruptures (1.6%), 3 cases of patellar maltracking (1.0%), and 2 periprosthetic patellar fractures (0.7%). Of 118 2-stage revisions for infection, an all-polyethylene component was used in 88 (74.6%), patelloplasty in 20 (16.9%), and patellectomy in 7 (5.9%). Patella-related complications included 4 cases of patellar maltracking (3.4%), 3 extensor mechanism ruptures (2.5%), and 1 periprosthetic patellar fracture (0.8%). Conclusions: Septic revisions required concomitant lateral releases more frequently (38.1% vs 10.9%; P < .02) but had a similar rate of patellar complications (6.8% vs 3.3%; P = .40). No cases required rerevision specifically for failure of the patellar component. Patients who had a patelloplasty had worse postoperative Knee Society functional scores than those with a retained or revised patellar component. In most aseptic RTKAs, a well-fixed patellar component can be retained. If revision is required, a standard polyethylene component is sufficient in most septic and aseptic revisions. Rerevisions related to the patellar component are infrequent. Keywords: Patella, Revision total knee arthroplasty, Revision TKA, Extensor mechanism, TK

    Synovial fluid biomarkers for periprosthetic infection. Clin Orthop Relat Res.

    No full text
    Abstract Background We have previously described a unique gene expression signature exhibited by synovial fluid leukocytes in response to bacterial infection, identifying a number of potential biomarkers for infection. However, the diagnostic performance of these potential biomarkers in an immunoassay format is unknown. Questions/purposes We therefore evaluated the sensitivity, specificity, and accuracy of several potential synovial fluid biomarkers for infection, and compared them to current standards of testing for periprosthetic infection. Methods We prospectively collected synovial fluid from 14 patients classified as having a periprosthetic infection and 37 patients classified as having an aseptic failure. The synovial fluid samples were tested for 23 potential biomarkers for periprosthetic infection. We then determined differences in biomarker levels between infected and aseptic groups, then computed the sensitivity, specificity, positive predictive value, negative predictive value and accuracy for select biomarkers, and finally compared those to current standard tests for infection. Results Twelve synovial fluid biomarkers had substantially higher average levels in the synovial fluid of infected versus aseptic patients. Synovial fluid levels of IL-1 were a mean of 258 times higher in patients with a periprosthetic infection compared to patients having revision for aseptic diagnoses. Synovial fluid IL-1 and IL-6 levels correctly classified all patients in this study with a sensitivity, specificity, positive predictive value, negative predictive value and accuracy equal to 1. Several markers tested in this study outperformed the ESR and CRP tests. Conclusions Patients with a periprosthetic infection have elevated levels of numerous synovial fluid biomarkers, when compared to patients with aseptic diagnoses. Several of these biomarkers exhibited nearly ideal sensitivity, specificity, and accuracy in this study, suggesting that synovial fluid biomarkers could be a valuable tool for diagnosing periprosthetic infection
    corecore