46 research outputs found

    Case report: Surgical repair of a large tracheo-esophageal fistula in a patient with post-transplant esophageal lymphoproliferative disorder

    Full text link
    Introduction and importance The management of large malignant tracheo-esophageal fistulas (TEF) is not standardized. Herein, we report a case with a malignant TEF associated with esophageal post-transplant lymphoproliferative disorder (PTLD) for whom we successfully performed a surgical repair. This contributes to the knowledge on how to treat large acquired malignant TEFs. Case presentation A 69-year old male presented with a one-week history of fever, productive cough and bilateral coarse crackles. In addition, he described a weight loss of 10 kg during the past three months. The patient's history included a kidney transplantation twenty years ago. Esophagogastroduodenoscopy with a biopsy of the esophagus was performed nine days before. Histopathology showed a PTLD of diffuse large B-cell lymphoma subtype. Subsequent diagnostics revealed a progressive TEF (approx. 2.0 × 1.5 cm) 3.0 cm above the carina. PET-CT scan showed an esophagus with slight tracer uptake in the middle third (approx. 11.5 cm length, SUV max 7.4). After decision against stenting, transthoracic subtotal esophagectomy with closure of the tracheal mouth of the fistula by a pedicled flap was performed. PTLD was treated with prednisone and rituximab. Tumor progression (brain metastasis) led to death 95 days after surgery. Clinical discussion The treatment of a malignant TEF is complex and personalized while both the consequences of the esophago-tracheal connection and those of the underlying responsible diagnosis have to be considered concurrently. In this case, we considered surgery as the best treatment option due to a relatively good prognosis of the underlying diagnosis (PTLD) and a large fistula. Esophageal or dual stenting, the treatment of choice for small malignant TEF, would have been associated with a high risk of failure due to the wide trachea, extensively dilated esophagus, proximal location and large diameter of the fistula. Conclusion Surgery can be considered for patients with a large acquired malignant TEF and positive long-term prognosis of the underlying diagnosis. Due to the complexity of TEF management, immediate pre-operative multidisciplinary discussion is advised

    First-in-human Use of a Microsurgical Robotic System for Central Lymphatic Reconstruction

    Get PDF
    Advances in the development of robotic systems have recently enabled the use of robotic technology in reconstructive lymphatic surgery. Although the advantages of microsurgical robots must be weighed carefully against the costs, their use may allow for smaller surgical approaches and easier access to anatomically deeper structures or even smaller vessels. We report on a case of a patient with central lymphatic dilation causing abdominal pain and severely reduced physical capacity. Sonography-assisted intranodal injection of indocyanine green allowed for localization of the lymphatic cyst and anastomosis with the left ovarian vein, applying robotic-assisted microsurgery for the first time on the central lymphatic system. Following the successful reconstruction of lymphatic drainage and decompression of the cyst, the patient reported a complete regression of her preoperative symptoms. From a surgical point of view, the Symani Surgical System improved precision and allowed significantly smaller surgical access. Considering the high morbidity and rarity of pathologies of the central lymphatic system, central lymphatic surgery is to date rarely performed. With improved precision and significantly smaller surgical access, robotic-assisted microsurgery has great potential to expand the treatment options for central lymphatic lesions

    Microsurgical central lymphatic reconstruction-the role of thoracic duct lymphovenous anastomoses at different anatomical levels

    Get PDF
    INTRODUCTION In recent years advances have been made in the microsurgical treatment of congenital or acquired central lymphatic lesions. While acquired lesions can result from any surgery or trauma of the central lymphatic system, congenital lymphatic lesions can have a variety of manifestations, ranging from singular thoracic duct abnormalities to complex multifocal malformations. Both conditions may cause recurrent chylous effusions and downstream lymphatic congestion depending on the anatomical location of the thoracic duct lesion and are associated with an increased mortality due to the permanent loss of protein and fluid. METHODS We present a case series of eleven patients undergoing central lymphatic reconstruction, consisting of one patient with a cervical iatrogenic thoracic duct lesion and eleven patients with different congenital thoracic duct lesions or thrombotic occlusions. RESULTS Anastomosis of the thoracic duct and a nearby vein was performed on different anatomical levels depending on the underlying central lymphatic pathology. Cervical (n = 4), thoracic (n = 1) or abdominal access (n = 5) was used for central lymphatic reconstruction with promising results. In 9 patients a postoperative benefit with varying degrees of symptom regression was reported. CONCLUSION The presented case series illustrates the current rapid advances in the field of central microsurgical reconstruction of lymphatic lesions alongside the relevant literature

    Delivering Safe Surgical Care While Simultaneously Caring for Patients With COVID-19; Assessment of Patient Selection, Volume and Outcomes in a Tertiary Care Hospital

    Get PDF
    Objectives: Compare patient selection and postoperative outcomes after surgical treatment for gastrointestinal disorders before and during the SARS-CoV-2 pandemic. Methods: We assessed gastrointestinal surgeries conducted at a tertiary center from 2017-2021 for differences in patient populations and procedures before (up to February 2020) and during the pandemic (March 2020 to December 2021). We analyzed mortality, Intensive Care Unit (ICU) length of stay, admission to ICU and postoperative complications for complex procedures using descriptive statistics and regression models. Results: 7309 procedures were analyzed, showing a caseload reduction in March and October 2020, but no statistical evidence for fewer overall procedures overall. Population characteristics differed with lower Body Mass Indices in 2020 and 2021, more patients smoking and with diabetes treated in 2020. There was no increased mortality, ICU length of stay and in 1,144 complex procedures assessed low overall morbidity at 90 days postoperative. Conclusion: Delivering surgical care while treating patients for COVID-19 in the same hospital was safe. Healthcare officials should consider continuing surgical care during future health crises as consequences of limiting surgical treatment for gastrointestinal disorders may be fatal for patients

    Delivering Safe Surgical Care While Simultaneously Caring for Patients With COVID-19; Assessment of Patient Selection, Volume and Outcomes in a Tertiary Care Hospital

    Get PDF
    Objectives: Compare patient selection and postoperative outcomes after surgical treatment for gastrointestinal disorders before and during the SARS-CoV-2 pandemic.Methods: We assessed gastrointestinal surgeries conducted at a tertiary center from 2017–2021 for differences in patient populations and procedures before (up to February 2020) and during the pandemic (March 2020 to December 2021). We analyzed mortality, Intensive Care Unit (ICU) length of stay, admission to ICU and postoperative complications for complex procedures using descriptive statistics and regression models.Results: 7309 procedures were analyzed, showing a caseload reduction in March and October 2020, but no statistical evidence for fewer overall procedures overall. Population characteristics differed with lower Body Mass Indices in 2020 and 2021, more patients smoking and with diabetes treated in 2020. There was no increased mortality, ICU length of stay and in 1,144 complex procedures assessed low overall morbidity at 90 days postoperative.Conclusion: Delivering surgical care while treating patients for COVID-19 in the same hospital was safe. Healthcare officials should consider continuing surgical care during future health crises as consequences of limiting surgical treatment for gastrointestinal disorders may be fatal for patients

    A search for resonances decaying into a Higgs boson and a new particle X in the XH→qqbb final state with the ATLAS detector

    Get PDF
    A search for heavy resonances decaying into a Higgs boson (HH) and a new particle (XX) is reported, utilizing 36.1 fb1^{-1} of proton-proton collision data at s=\sqrt{s} = 13 TeV collected during 2015 and 2016 with the ATLAS detector at the CERN Large Hadron Collider. The particle XX is assumed to decay to a pair of light quarks, and the fully hadronic final state XHqqˉbbˉXH \rightarrow q\bar q'b\bar b is analysed. The search considers the regime of high XHXH resonance masses, where the XX and HH bosons are both highly Lorentz-boosted and are each reconstructed using a single jet with large radius parameter. A two-dimensional phase space of XHXH mass versus XX mass is scanned for evidence of a signal, over a range of XHXH resonance mass values between 1 TeV and 4 TeV, and for XX particles with masses from 50 GeV to 1000 GeV. All search results are consistent with the expectations for the background due to Standard Model processes, and 95% CL upper limits are set, as a function of XHXH and XX masses, on the production cross-section of the XHqqˉbbˉXH\rightarrow q\bar q'b\bar b resonance

    Study of ordered hadron chains with the ATLAS detector

    Get PDF
    La lista completa de autores que integran el documento puede consultarse en el archivo

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Measurement of the charge asymmetry in top-quark pair production in the lepton-plus-jets final state in pp collision data at s=8TeV\sqrt{s}=8\,\mathrm TeV{} with the ATLAS detector

    Get PDF

    ATLAS Run 1 searches for direct pair production of third-generation squarks at the Large Hadron Collider

    Get PDF
    corecore