3,442 research outputs found
Analysis of industrial contaminants in indoor air. Part 2. Emergent contaminants and pesticides
This article reviews recent literature on the analysis of several contaminants related to the industrial development in indoor air in the framework of the REACH project. In this second part, the attention is focused on emergent contaminants and biocides. Among these chemicals, phthalates, polybrominated and phosphate flame retardants, fragrances, pesticides, as well as other emerging pollutants, are increasing their environmental and health concern and are extensively found in indoor air. Some of them are suspected to behave as priority organic pollutants (POPs) and/or endocrine disrupting compounds (EDC), and can be found both in air and associated to the suspended particulate matter (PM) and settled dust. Main literature considered for this review is from the last ten years, reporting analytical developments and applications regarding the considered contaminants in the indoor environment. Sample collection and pretreatment, analyte extraction or desorption, clean-up procedures, determination techniques, and performance results are summarized and discussed.S
The Wind Employment in Spain (1995-2010): A Theoretical Approximation Applied to the Region of Galicia
The development of the renewable energies, and especially of the wind power, in the last decades has stayed out of any discussion. The advantages associated with the energy of the odd wind have considered in occasions authentic information that they them should corroborate. For example, about the streghness of creating jobs, there do not exist official statistics that gather the dimension of the created employment, without forgetting that the field of the energy stands out for being intensive in the capital. In this paper, there is realized an analysis of the different bibliographical sources relative to the generation of employment in the wind sector in Spain, establishing a few margins of the creation of the same one for categories for the region of Galicia, in the period (1995-2010).
Keywords: Renewable energy; wind energy; wind promotors
JEL Classifications: Q25; Q43; 01
Inter-laboratory comparison of methods to measure androstenone in pork fat
Today, different analytical methods are used by different laboratories to quantify androstenone in fat tissue. This study shows the comparison of methods used routinely in different laboratories for androstenone quantification: Time-resolved fluoroimmunoassay in Norwegian School of Veterinary Science (NSVS; Norway), gas chromatography coupled to mass spectrometry in Co-operative Central Laboratory (CCL; The Netherlands) and in Institut de Recerca i Tecnologia AgroalimentĂ ries (IRTA; Spain), and high-pressure liquid chromatography in Agroscope Liebefeld-Posieux Research Station (ALP; Switzerland). In a first trial, a set of adipose tissue (AT) samples from 53 entire males was sent to CCL, IRTA and NSVS for determination of androstenone concentration. The average androstenone concentration (s.d.) was 2.47 (2.10) ÎŒg/g at NSVS, 1.31 (0.98) ÎŒg/g at CCL and 0.62 (0.52) ÎŒg/g at IRTA. Despite the large differences in absolute values, inter-laboratory correlations were high, ranging from 0.82 to 0.92. A closer look showed differences in the preparation step. Indeed, different matrices were used for the analysis: pure fat at NSVS, melted fat at CCL and AT at IRTA. A second trial was organised in order to circumvent the differences in sample preparation. Back fat samples from 10 entire males were lyophilised at the ALP labortary in Switzerland and were sent to the other laboratories for androstenone concentration measurement. The average concentration (s.d.) of androstenone in the freeze-dried AT samples was 0.87 (0.52), 1.03 (0.55), 0.84 (0.46) and 0.99 (0.67) ÎŒg/g at NSVS, CCL, IRTA and ALP, respectively, and the pairwise correlations between laboratories ranged from 0.92 to 0.97. Thus, this study shows the influence of the different sample preparation protocols, leading to major differences in the results, although still allowing high inter-laboratory correlations. The results further highlight the need for method standardisation and inter-laboratory ring tests for the determination of androstenone. This standardisation is especially relevant when deriving thresholds of consumer acceptance, whereas the ranking of animals for breeding purposes will be less affected due to the high correlations between method
Hematopoietic stem cell transplantation in children with chronic granulomatous disease: the Spanish experience
Children; Chronic granulomatous disease; Graft failureNens; Malaltia granulomatosa crĂČnica; FracĂ s de l'empeltNiños; Enfermedad granulomatosa crĂłnica; Fracaso del injertoIntroduction: Hematopoietic stem cell transplantation (HCT) can cure chronic granulomatous disease (CGD). However, transplant-associated morbidity or mortality may occur, and it is still controversial which patients benefit from this procedure. The aim of this retrospective study was to evaluate the outcome of pediatric patients who received HCT in one of the Spanish pediatric transplant units.
Results: Thirty children with a median age of 6.9 years (range 0.6â12.7) were evaluated: 8 patients received a transplant from a sibling donor (MSD), 21 received a transplant from an unrelated donor (UD), and 1 received a haploidentical transplant. The majority of the patients received reduced-intensity conditioning regimens based on either busulfan plus fludarabine or treosulfan. Relevant post-HCT complications were as follows: i) graft failure (GF), with a global incidence of 28.26% (CI: 15.15â48.88), 11.1% in patients with MSD (1.64â56.70) and 37.08% in unrelated donors (19.33â63.17); and ii) chronic graft-versus-host disease (GVHD), with an incidence of 20.5% (8.9â43.2), 11.1% in patients with MSD (1.64â56.70) and 26.7% in unrelated donors (10.42â58.44). Post-HCT infections were usually manageable, but two episodes of pulmonary aspergillosis were diagnosed in the context of graft rejection. The 2-year OS was 77.3% (55.92â89.23). There were no statistically significant differences among donor types.
Discussion: HCT in patients with CGD is a complex procedure with significant morbidity and mortality, especially in patients who receive grafts from unrelated donors. These factors need to be considered in the decision-making process and when discussing conditioning and GVHD prophylaxis
Pooling for SARS-CoV-2 control in care institutions
BACKGROUND: Workers and residents in Care Homes are considered at special risk for the acquisition of SARS-CoV-2 infection, due to the infectivity and high mortality rate in the case of residents, compared to other containment areas. The role of presymptomatic people in transmission has been shown to be important and the early detection of these people is critical for the control of new outbreaks. Pooling strategies have proven to preserve SARS-CoV-2 testing resources. The aims of the present study, based in our local experience, were (a) to describe SARS-CoV-2 prevalence in institutionalized people in Galicia (Spain) during the Coronavirus pandemic and (b) to evaluate the expected performance of a pooling strategy using RT-PCR for the next rounds of screening of institutionalized people. METHODS: A total of 25,386 Nasopharyngeal swab samples from the total of the residents and workers at Care Homes in Galicia (March to May 2020) were individually tested using RT-PCR. Prevalence and quantification cycle (Cq) value distribution of positives was calculated. Besides, 26 pools of 20 samples and 14 pools of 5 samples were tested using RT-PCR as well (1 positive/pool). Pooling proof of concept was performed in two populations with 1.7 and 2% prevalence. RESULTS: Distribution of SARS-CoV-2 infection at Care Homes was uneven (0-60%). As the virus circulation global rate was low in our area (3.32%), the number of people at risk of acquiring the infection continues to be very high. In this work, we have successfully demonstrated that pooling of different groups of samples at low prevalence clusters, can be done with a small average delay on Cq values (5 and 2.85 cycles for pools of 20 and 5 samples, respectively). CONCLUSIONS: A new screening system with guaranteed protection is required for small clusters, previously covered with individual testing. Our proposal for Care Homes, once prevalence zero is achieved, would include successive rounds of testing using a pooling solution for transmission control preserving testing resources. Scale-up of this method may be of utility to confront larger clusters to avoid the viral circulation and keeping them operative
Management plan and surveillance monitoring for an urban lake in a coastal touristic town
Urban lakes have been created for different purposes, such as storing rainwater and avoiding flooding of adjacent urban areas. As an added value, they can be important recreational areas with an intrinsic aesthetic value. These artificial systems are characterised by very shallow waters, large amount of nutrient inputs and reduced water flow. These characteristics make them very prone to eutrophication process with the consequent deterioration of water quality and aesthetic value. The objective of this study is to present the management plan for a small urban lake (11,264 m2 and 1.5 m average depth) in Tavernes de la Valldigna (Valencia, Spain). This urban lake was constructed in a natural depression after the important flooding caused by the JĂșcar River overflow (15,000 m3/s peak flow) and the breaking of the Tous Dam in 1982. It works as storm tank and it has a pumping station to alleviate flow directly to the Mediterranean Sea. Around the lake, there is a recreational area that is mostly used in summer during touristic season. Since its construction it has suffered repeated events of fish deaths and bad odours that cause the alarm of residents and tourists. Municipal authorities worried by the environmental health risk and the economic impact on the tourism industry decided to undertake a restoration project. The results of this study present the initial status diagnosis and the propose d management plan. For guarantying the success of the implemented measures, a surveillance monitoring is designed.SebastiĂĄ-Frasquet, M.; SanchĂs Blay, JA.; Tormo-Flores, JB.; Altur Grau, VJ.; Pena-Regueiro, J. (2016). Management plan and surveillance monitoring for an urban lake in a coastal touristic town. International Journal of Sustainable Development and Planning. 11(6):886-896. doi:10.2495/SDP-V11-N6-886-896S88689611
Systematic review of surgical interventions for Crohn's anal fistula
Background Anal fistula occurs in approximately one in three patients with Crohn's disease and is typically managed through a multimodal approach. The optimal surgical therapy is not yet clear. The aim of this systematic review was to identify and assess the literature on surgical treatments of Crohn's anal fistula. Methods A systematic review was conducted that analysed studies relating to surgical treatment of Crohn's anal fistula published on MEDLINE, Embase and Cochrane databases between January 1995 and March 2016. Studies reporting specific outcomes of patients treated for Crohn's anal fistula were included. The primary outcome was fistula healing rate. Bias was assessed using the Cochrane ROBINSâI and ROB tool as appropriate. Results A total of 1628 citations were reviewed. Sixtyâthree studies comprising 1584 patients were ultimately selected in the analyses. There was extensive reporting on the use of setons, advancement flaps and fistula plugs. Randomized trials were available only for stem cells and fistula plugs. There was inconsistency in outcome measures across studies, and a high degree of bias was noted. Conclusion Data describing surgical intervention for Crohn's anal fistula are heterogeneous with a high degree of bias. There is a clear need for standardization of outcomes and description of study cohorts for better understanding of treatment options
Observation of an Excited Bc+ State
Using pp collision data corresponding to an integrated luminosity of 8.5 fb-1 recorded by the LHCb experiment at center-of-mass energies of s=7, 8, and 13 TeV, the observation of an excited Bc+ state in the Bc+Ï+Ï- invariant-mass spectrum is reported. The observed peak has a mass of 6841.2±0.6(stat)±0.1(syst)±0.8(Bc+) MeV/c2, where the last uncertainty is due to the limited knowledge of the Bc+ mass. It is consistent with expectations of the Bcâ(2S31)+ state reconstructed without the low-energy photon from the Bcâ(1S31)+âBc+Îł decay following Bcâ(2S31)+âBcâ(1S31)+Ï+Ï-. A second state is seen with a global (local) statistical significance of 2.2Ï (3.2Ï) and a mass of 6872.1±1.3(stat)±0.1(syst)±0.8(Bc+) MeV/c2, and is consistent with the Bc(2S10)+ state. These mass measurements are the most precise to date
Differential branching fraction and angular analysis of the decay B0âKâ0ÎŒ+ÎŒâ
The angular distribution and differential branching fraction of the decay B 0â K â0 ÎŒ + ÎŒ â are studied using a data sample, collected by the LHCb experiment in pp collisions at sâ=7 TeV, corresponding to an integrated luminosity of 1.0 fbâ1. Several angular observables are measured in bins of the dimuon invariant mass squared, q 2. A first measurement of the zero-crossing point of the forward-backward asymmetry of the dimuon system is also presented. The zero-crossing point is measured to be q20=4.9±0.9GeV2/c4 , where the uncertainty is the sum of statistical and systematic uncertainties. The results are consistent with the Standard Model predictions
Model-independent search for CP violation in D0âKâK+ÏâÏ+ and D0âÏâÏ+Ï+Ïâ decays
A search for CP violation in the phase-space structures of D0 and View the MathML source decays to the final states KâK+ÏâÏ+ and ÏâÏ+Ï+Ïâ is presented. The search is carried out with a data set corresponding to an integrated luminosity of 1.0 fbâ1 collected in 2011 by the LHCb experiment in pp collisions at a centre-of-mass energy of 7 TeV. For the KâK+ÏâÏ+ final state, the four-body phase space is divided into 32 bins, each bin with approximately 1800 decays. The p-value under the hypothesis of no CP violation is 9.1%, and in no bin is a CP asymmetry greater than 6.5% observed. The phase space of the ÏâÏ+Ï+Ïâ final state is partitioned into 128 bins, each bin with approximately 2500 decays. The p-value under the hypothesis of no CP violation is 41%, and in no bin is a CP asymmetry greater than 5.5% observed. All results are consistent with the hypothesis of no CP violation at the current sensitivity
- âŠ