111 research outputs found

    Sociology’s missed opportunity: John Stuart-Glennie’s lost theory of the moral revolution, also known as the axial age

    Get PDF
    In 1873, 75 years before Karl Jaspers published his theory of the Axial Age in 1949, unknown to Jaspers and to contemporary scholars today, Scottish folklorist John Stuart Stuart-Glennie elaborated the first fully developed and nuanced theory of what he termed “the Moral Revolution” to characterize the historical shift emerging roughly around 600 BCE in a variety of civilizations, most notably ancient China, India, Judaism, and Greece, as part of a broader critical philosophy of history. He continued to write on the idea over decades in books and articles and also presented his ideas to the fledgling Sociological Society of London in 1905, which were published the following year in the volume Sociological Papers, Volume 2. This article discusses Stuart-Glennie’s ideas on the moral revolution in the context of his philosophy of history, including what he termed “panzooinism”; ideas with implications for contemporary debates in theory, comparative history, and sociology of religion. It shows why he should be acknowledged as the originator of the theory now known as the axial age, and also now be included as a significant sociologist in the movement toward the establishment of sociology

    Acromioclavicular joint reconstruction with coracoacromial ligament transfer using the docking technique

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Symptomatic Acromioclavicular (AC) dislocations have historically been surgically treated with Coracoclavicular (CC) ligament reconstruction with transfer of the Coracoacromial (CA) ligament. Tensioning the CA ligament is the key to success.</p> <p>Methods</p> <p>Seventeen patients with chronic, symptomatic Type III AC joint or acute Type IV and V injuries were treated surgically. The distal clavicle was resected and stabilized with CC ligament reconstruction using the CA ligament. The CA ligament was passed into the medullary canal and tensioned, using a modified 'docking' technique. Average follow-up was 29 months (range 12–57).</p> <p>Results</p> <p>Postoperative ASES and pain significantly improved in all patients (p = 0.001). Radiographically, 16 (94%) maintained reduction, and only 1 (6%) had a recurrent dislocation when he returned to karate 3 months postoperatively. His ultimate clinical outcome was excellent.</p> <p>Conclusion</p> <p>The docking procedure allows for tensioning of the transferred CA ligament and healing of the ligament in an intramedullary bone tunnel. Excellent clinical results were achieved, decreasing the risk of recurrent distal clavicle instability.</p

    Acromioclavicular joint dislocation: a comparative biomechanical study of the palmaris-longus tendon graft reconstruction with other augmentative methods in cadaveric models

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Acromioclavicular injuries are common in sports medicine. Surgical intervention is generally advocated for chronic instability of Rockwood grade III and more severe injuries. Various methods of coracoclavicular ligament reconstruction and augmentation have been described. The objective of this study is to compare the biomechanical properties of a novel palmaris-longus tendon reconstruction with those of the native AC+CC ligaments, the modified Weaver-Dunn reconstruction, the ACJ capsuloligamentous complex repair, screw and clavicle hook plate augmentation.</p> <p>Hypothesis</p> <p>There is no difference, biomechanically, amongst the various reconstruction and augmentative methods.</p> <p>Study Design</p> <p>Controlled laboratory cadaveric study.</p> <p>Methods</p> <p>54 cadaveric native (acromioclavicular and coracoclavicular) ligaments were tested using the Instron machine. Superior loading was performed in the 6 groups: 1) in the intact states, 2) after modified Weaver-Dunn reconstruction (WD), 3) after modified Weaver-Dunn reconstruction with acromioclavicular joint capsuloligamentous repair (WD.ACJ), 4) after modified Weaver-Dunn reconstruction with clavicular hook plate augmentation (WD.CP) or 5) after modified Weaver-Dunn reconstruction with coracoclavicular screw augmentation (WD.BS) and 6) after modified Weaver-Dunn reconstruction with mersilene tape-palmaris-longus tendon graft reconstruction (WD. PLmt). Posterior-anterior (horizontal) loading was similarly performed in all groups, except groups 4 and 5. The respective failure loads, stiffnesses, displacements at failure and modes of failure were recorded. Data analysis was carried out using a one-way ANOVA, with Student's unpaired t-test for unpaired data (S-PLUS statistical package 2005).</p> <p>Results</p> <p>Native ligaments were the strongest and stiffest when compared to other modes of reconstruction and augmentation except coracoclavicular screw, in both posterior-anterior and superior directions (p < 0.005).</p> <p>WD.ACJ provided additional posterior-anterior (P = 0. 039) but not superior (p = 0.250) stability when compared to WD alone.</p> <p>WD+PLmt, in loads and stiffness at failure superiorly, was similar to WD+CP (p = 0.066). WD+PLmt, in loads and stiffness at failure postero-anteriorly, was similar to WD+ACJ (p = 0.084).</p> <p>Superiorly, WD+CP had similar strength as WD+BS (p = 0.057), but it was less stiff (p < 0.005).</p> <p>Conclusions and Clinical Relevance</p> <p>Modified Weaver-Dunn procedure must always be supplemented with acromioclavicular capsuloligamentous repair to increase posterior-anterior stability. Palmaris-Longus tendon graft provides both additional superior and posterior-anterior stability when used for acromioclavicular capsuloligamentous reconstruction. It is a good alternative to clavicle hook plate in acromioclavicular dislocation.</p

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    CMS Data Processing Workflows during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Global burden of 369 diseases and injuries in 204 countries and territories, 1990-2019: a systematic analysis for the Global Burden of Disease Study 2019

    Get PDF

    Five insights from the Global Burden of Disease Study 2019

    Get PDF
    The Global Burden of Diseases, Injuries, and Risk Factors Study (GBD) 2019 provides a rules-based synthesis of the available evidence on levels and trends in health outcomes, a diverse set of risk factors, and health system responses. GBD 2019 covered 204 countries and territories, as well as first administrative level disaggregations for 22 countries, from 1990 to 2019. Because GBD is highly standardised and comprehensive, spanning both fatal and non-fatal outcomes, and uses a mutually exclusive and collectively exhaustive list of hierarchical disease and injury causes, the study provides a powerful basis for detailed and broad insights on global health trends and emerging challenges. GBD 2019 incorporates data from 281 586 sources and provides more than 3.5 billion estimates of health outcome and health system measures of interest for global, national, and subnational policy dialogue. All GBD estimates are publicly available and adhere to the Guidelines on Accurate and Transparent Health Estimate Reporting. From this vast amount of information, five key insights that are important for health, social, and economic development strategies have been distilled. These insights are subject to the many limitations outlined in each of the component GBD capstone papers.Peer reviewe
    corecore