39 research outputs found

    Variability in Serum Sodium Concentration and Prognostic Significance in Severe Traumatic Brain Injury: A Multicenter Observational Study.

    Get PDF
    BACKGROUND/OBJECTIVE: Dysnatremia is common in severe traumatic brain injury (TBI) patients and may contribute to mortality. However, serum sodium variability has not been studied in TBI patients. We hypothesized that such variability would be independently associated with mortality. METHODS: We collected 6-hourly serum sodium levels for the first 7 days of ICU admission from 240 severe TBI patients in 14 neurotrauma ICUs in Europe and Australia. We evaluated the association between daily serum sodium standard deviation (dNaSD), an index of variability, and 28-day mortality. RESULTS: Patients were 46 ± 19 years of age with a median initial GCS of 6 [4-8]. Overall hospital mortality was 28%. Hypernatremia and hyponatremia occurred in 64% and 24% of patients, respectively. Over the first 7 days in ICU, serum sodium standard deviation was 2.8 [2.0-3.9] mmol/L. Maximum daily serum sodium standard deviation (dNaSD) occurred at a median of 2 [1-4] days after admission. There was a significant progressive decrease in dNaSD over the first 7 days (coefficient - 0.15 95% CI [- 0.18 to - 0.12], p < 0.001). After adjusting for baseline TBI severity, diabetes insipidus, the use of osmotherapy, the occurrence of hypernatremia, and hyponatremia and center, dNaSD was significantly independently associated with 28-day mortality (HR 1.27 95% CI (1.01-1.61), p = 0.048). CONCLUSIONS: Our study demonstrates that daily serum sodium variability is an independent predictor of 28-day mortality in severe TBI patients. Further prospective investigations are necessary to confirm the significance of sodium variability in larger cohorts of TBI patients and test whether attenuating such variability confers outcome benefits to such patients

    Early Osmotherapy in Severe Traumatic Brain Injury : An International Multicenter Study

    Get PDF
    The optimal osmotic agent to treat intracranial hypertension in patients with severe traumatic brain injury (TBI) remains uncertain. We aimed to test whether the choice of mannitol or hypertonic saline (HTS) as early (first 96 h) osmotherapy in these patients might be associated with a difference in mortality. We retrospectively analyzed data from 2015 from 14 tertiary intensive care units (ICUs) in Australia, UK, and Europe treating severe TBI patients with intracranial pressure (ICP) monitoring and compared mortality in those who received mannitol only versus HTS only. We performed multi-variable analysis adjusting for site and illness severity (Injury Severity Score, extended IMPACT score, and mean ICP over the first 96 h) using Cox proportional hazards regression. We collected data on 262 patients and compared patients who received early osmotherapy with mannitol alone (n = 46) with those who received HTS alone (n = 46). Mannitol patients were older (median age, 49.2 (19.2) vs. 40.5 (16.8) years; p = 0.02), with higher Injury Severity Scores (42 (15.9) vs. 32.1 [11.3]; p = 0.001), and IMPACT-TBI predicted 6-month mortality (34.5% [23-46] vs. 25% [13-38]; p = 0.02), but had similar APACHE-II scores, and mean and maximum ICPs over the first 96 h. The unadjusted hazard ratio for in-hospital mortality in patients receiving only mannitol was 3.35 (95% confidence interval [CI], 1.60-7.03; p = 0.001). After adjustment for key mortality predictors, the hazard ratio for in-hospital mortality in patients receiving only mannitol was 2.64 (95% CI, 0.96-7.30; p = 0.06). The choice of early osmotherapy in severe TBI patients may affect survival, or simply reflect clinician beliefs about their different roles, and warrants controlled investigation.Peer reviewe

    Transcranial Doppler as a screening test to exclude intracranial hypertension in brain-injured patients: the IMPRESSIT-2 prospective multicenter international study

    Get PDF
    Background: Alternative noninvasive methods capable of excluding intracranial hypertension through use of transcranial Doppler (ICPtcd) in situations where invasive methods cannot be used or are not available would be useful during the management of acutely brain-injured patients. The objective of this study was to determine whether ICPtcd can be considered a reliable screening test compared to the reference standard method, invasive ICP monitoring (ICPi), in excluding the presence of intracranial hypertension. Methods: This was a prospective, international, multicenter, unblinded, diagnostic accuracy study comparing the index test (ICPtcd) with a reference standard (ICPi), defined as the best available method for establishing the presence or absence of the condition of interest (i.e., intracranial hypertension). Acute brain-injured patients pertaining to one of four categories: traumatic brain injury (TBI), subarachnoid hemorrhage (SAH), intracerebral hemorrhage (ICH) or ischemic stroke (IS) requiring ICPi monitoring, were enrolled in 16 international intensive care units. ICPi measurements (reference test) were compared to simultaneous ICPtcd measurements (index test) at three different timepoints: before, immediately after and 2 to 3&nbsp;h following ICPi catheter insertion. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated at three different ICPi thresholds (&gt; 20, &gt; 22 and &gt; 25&nbsp;mmHg) to assess ICPtcd as a bedside real-practice screening method. A receiver operating characteristic (ROC) curve analysis with the area under the curve (AUC) was used to evaluate the discriminative accuracy and predictive capability of ICPtcd. Results: Two hundred and sixty-two patients were recruited for final analysis. Intracranial hypertension (&gt; 22&nbsp;mmHg) occurred in 87 patients (33.2%). The total number of paired comparisons between ICPtcd and ICPi was 687. The NPV was elevated (ICP &gt; 20&nbsp;mmHg = 91.3%, &gt; 22&nbsp;mmHg = 95.6%, &gt; 25&nbsp;mmHg = 98.6%), indicating high discriminant accuracy of ICPtcd in excluding intracranial hypertension. Concordance correlation between ICPtcd and ICPi was 33.3% (95% CI 25.6-40.5%), and Bland-Altman showed a mean bias of -3.3&nbsp;mmHg. The optimal ICPtcd threshold for ruling out intracranial hypertension was 20.5&nbsp;mmHg, corresponding to a sensitivity of 70% (95% CI 40.7-92.6%) and a specificity of 72% (95% CI 51.9-94.0%) with an AUC of 76% (95% CI 65.6-85.5%). Conclusions and relevance: ICPtcd has a high NPV in ruling out intracranial hypertension and may be useful to clinicians in situations where invasive methods cannot be used or not available. Trial registration: NCT02322970

    The Fourteenth Data Release of the Sloan Digital Sky Survey: First Spectroscopic Data from the extended Baryon Oscillation Spectroscopic Survey and from the second phase of the Apache Point Observatory Galactic Evolution Experiment

    Get PDF
    The fourth generation of the Sloan Digital Sky Survey (SDSS-IV) has been in operation since July 2014. This paper describes the second data release from this phase, and the fourteenth from SDSS overall (making this, Data Release Fourteen or DR14). This release makes public data taken by SDSS-IV in its first two years of operation (July 2014-2016). Like all previous SDSS releases, DR14 is cumulative, including the most recent reductions and calibrations of all data taken by SDSS since the first phase began operations in 2000. New in DR14 is the first public release of data from the extended Baryon Oscillation Spectroscopic Survey (eBOSS); the first data from the second phase of the Apache Point Observatory (APO) Galactic Evolution Experiment (APOGEE-2), including stellar parameter estimates from an innovative data driven machine learning algorithm known as "The Cannon"; and almost twice as many data cubes from the Mapping Nearby Galaxies at APO (MaNGA) survey as were in the previous release (N = 2812 in total). This paper describes the location and format of the publicly available data from SDSS-IV surveys. We provide references to the important technical papers describing how these data have been taken (both targeting and observation details) and processed for scientific use. The SDSS website (www.sdss.org) has been updated for this release, and provides links to data downloads, as well as tutorials and examples of data use. SDSS-IV is planning to continue to collect astronomical data until 2020, and will be followed by SDSS-V.Comment: SDSS-IV collaboration alphabetical author data release paper. DR14 happened on 31st July 2017. 19 pages, 5 figures. Accepted by ApJS on 28th Nov 2017 (this is the "post-print" and "post-proofs" version; minor corrections only from v1, and most of errors found in proofs corrected

    Development of a quality indicator set to measure and improve quality of ICU care for patients with traumatic brain injury.

    Get PDF
    BACKGROUND: We aimed to develop a set of quality indicators for patients with traumatic brain injury (TBI) in intensive care units (ICUs) across Europe and to explore barriers and facilitators for implementation of these quality indicators. METHODS: A preliminary list of 66 quality indicators was developed, based on current guidelines, existing practice variation, and clinical expertise in TBI management at the ICU. Eight TBI experts of the Advisory Committee preselected the quality indicators during a first Delphi round. A larger Europe-wide expert panel was recruited for the next two Delphi rounds. Quality indicator definitions were evaluated on four criteria: validity (better performance on the indicator reflects better processes of care and leads to better patient outcome), feasibility (data are available or easy to obtain), discriminability (variability in clinical practice), and actionability (professionals can act based on the indicator). Experts scored indicators on a 5-point Likert scale delivered by an electronic survey tool. RESULTS: The expert panel consisted of 50 experts from 18 countries across Europe, mostly intensivists (N = 24, 48%) and neurosurgeons (N = 7, 14%). Experts agreed on a final set of 42 indicators to assess quality of ICU care: 17 structure indicators, 16 process indicators, and 9 outcome indicators. Experts are motivated to implement this finally proposed set (N = 49, 98%) and indicated routine measurement in registries (N = 41, 82%), benchmarking (N = 42, 84%), and quality improvement programs (N = 41, 82%) as future steps. Administrative burden was indicated as the most important barrier for implementation of the indicator set (N = 48, 98%). CONCLUSIONS: This Delphi consensus study gives insight in which quality indicators have the potential to improve quality of TBI care at European ICUs. The proposed quality indicator set is recommended to be used across Europe for registry purposes to gain insight in current ICU practices and outcomes of patients with TBI. This indicator set may become an important tool to support benchmarking and quality improvement programs for patients with TBI in the future

    El cultivo del caqui

    Get PDF
    En este libro se escribe del caqui en toda su amplitud, los mejores investigadores en las diferentes especialidades nos explican los resultados de la investigación y experiencias en fertirrigación, pies y variedades, sanidad vegetal, poda y postcosecha; acompañado y documentado de una amplia bibliografía de los investigadores de los principales países productores del mundo: China, Japón e Israel, e Italia, mås que por su producción, por su continua y avanzada investigación. Este libro, fruto del trabajo de las diferentes líneas de investigación del producto, coordinada por el magnífico equipo de investigadores del IVIA, pone a disposición de la producción, postcosecha y comercialización todos los avances conocidos a nivel nacional e internacional

    Sloan Digital Sky Survey IV: Mapping the Milky Way, Nearby Galaxies, and the Distant Universe

    Get PDF
    We describe the Sloan Digital Sky Survey IV (SDSS-IV), a project encompassing three major spectroscopic programs. The Apache Point Observatory Galactic Evolution Experiment 2 (APOGEE-2) is observing hundreds of thousands of Milky Way stars at high resolution and high signal-to-noise ratios in the near-infrared. The Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey is obtaining spatially resolved spectroscopy for thousands of nearby galaxies (median z∌0.03z\sim 0.03). The extended Baryon Oscillation Spectroscopic Survey (eBOSS) is mapping the galaxy, quasar, and neutral gas distributions between z∌0.6z\sim 0.6 and 3.5 to constrain cosmology using baryon acoustic oscillations, redshift space distortions, and the shape of the power spectrum. Within eBOSS, we are conducting two major subprograms: the SPectroscopic IDentification of eROSITA Sources (SPIDERS), investigating X-ray AGNs and galaxies in X-ray clusters, and the Time Domain Spectroscopic Survey (TDSS), obtaining spectra of variable sources. All programs use the 2.5 m Sloan Foundation Telescope at the Apache Point Observatory; observations there began in Summer 2014. APOGEE-2 also operates a second near-infrared spectrograph at the 2.5 m du Pont Telescope at Las Campanas Observatory, with observations beginning in early 2017. Observations at both facilities are scheduled to continue through 2020. In keeping with previous SDSS policy, SDSS-IV provides regularly scheduled public data releases; the first one, Data Release 13, was made available in 2016 July

    The Fifteenth Data Release of the Sloan Digital Sky Surveys: First Release of MaNGA-derived Quantities, Data Visualization Tools, and Stellar Library

    Get PDF
    Twenty years have passed since first light for the Sloan Digital Sky Survey (SDSS). Here, we release data taken by the fourth phase of SDSS (SDSS-IV) across its first three years of operation (2014 July–2017 July). This is the third data release for SDSS-IV, and the 15th from SDSS (Data Release Fifteen; DR15). New data come from MaNGA—we release 4824 data cubes, as well as the first stellar spectra in the MaNGA Stellar Library (MaStar), the first set of survey-supported analysis products (e.g., stellar and gas kinematics, emission-line and other maps) from the MaNGA Data Analysis Pipeline, and a new data visualization and access tool we call "Marvin." The next data release, DR16, will include new data from both APOGEE-2 and eBOSS; those surveys release no new data here, but we document updates and corrections to their data processing pipelines. The release is cumulative; it also includes the most recent reductions and calibrations of all data taken by SDSS since first light. In this paper, we describe the location and format of the data and tools and cite technical references describing how it was obtained and processed. The SDSS website (www.sdss.org) has also been updated, providing links to data downloads, tutorials, and examples of data use. Although SDSS-IV will continue to collect astronomical data until 2020, and will be followed by SDSS-V (2020–2025), we end this paper by describing plans to ensure the sustainability of the SDSS data archive for many years beyond the collection of data

    The 13th Data Release of the Sloan Digital Sky Survey: First Spectroscopic Data from the SDSS-IV Survey Mapping Nearby Galaxies at Apache Point Observatory

    Get PDF
    The fourth generation of the Sloan Digital Sky Survey (SDSS-IV) began observations in July 2014. It pursues three core programs: APOGEE-2,MaNGA, and eBOSS. In addition, eBOSS contains two major subprograms: TDSS and SPIDERS. This paper describes the first data release from SDSS-IV, Data Release 13 (DR13), which contains new data, reanalysis of existing data sets and, like all SDSS data releases, is inclusive of previously released data. DR13 makes publicly available 1390 spatially resolved integral field unit observations of nearby galaxies from MaNGA,the first data released from this survey. It includes new observations from eBOSS, completing SEQUELS. In addition to targeting galaxies and quasars, SEQUELS also targeted variability-selected objects from TDSS and X-ray selected objects from SPIDERS. DR13 includes new reductions ofthe SDSS-III BOSS data, improving the spectrophotometric calibration and redshift classification. DR13 releases new reductions of the APOGEE-1data from SDSS-III, with abundances of elements not previously included and improved stellar parameters for dwarf stars and cooler stars. For the SDSS imaging data, DR13 provides new, more robust and precise photometric calibrations. Several value-added catalogs are being released in tandem with DR13, in particular target catalogs relevant for eBOSS, TDSS, and SPIDERS, and an updated red-clump catalog for APOGEE.This paper describes the location and format of the data now publicly available, as well as providing references to the important technical papers that describe the targeting, observing, and data reduction. The SDSS website, http://www.sdss.org, provides links to the data, tutorials and examples of data access, and extensive documentation of the reduction and analysis procedures. DR13 is the first of a scheduled set that will contain new data and analyses from the planned ~6-year operations of SDSS-IV.PostprintPeer reviewe
    corecore