117 research outputs found

    Mid-mantle deformation inferred from seismic anisotropy

    Get PDF
    With time, convective processes in the Earth's mantle will tend to align crystals, grains and inclusions. This mantle fabric is detectable seismologically, as it produces an anisotropy in material properties—in particular, a directional dependence in seismic-wave velocity. This alignment is enhanced at the boundaries of the mantle where there are rapid changes in the direction and magnitude of mantle flow, and therefore most observations of anisotropy are confined to the uppermost mantle or lithosphere and the lowermost-mantle analogue of the lithosphere, the D" region. Here we present evidence from shear-wave splitting measurements for mid-mantle anisotropy in the vicinity of the 660-km discontinuity, the boundary between the upper and lower mantle. Deep-focus earthquakes in the Tonga–Kermadec and New Hebrides subduction zones recorded at Australian seismograph stations record some of the largest values of shear-wave splitting hitherto reported. The results suggest that, at least locally, there may exist a mid-mantle boundary layer, which could indicate the impediment of flow between the upper and lower mantle in this region

    Detection of cannabinoid receptor type 2 in native cells and zebrafish with a highly potent, cell-permeable fluorescent probe.

    Get PDF
    Despite its essential role in the (patho)physiology of several diseases, CB2R tissue expression profiles and signaling mechanisms are not yet fully understood. We report the development of a highly potent, fluorescent CB2R agonist probe employing structure-based reverse design. It commences with a highly potent, preclinically validated ligand, which is conjugated to a silicon-rhodamine fluorophore, enabling cell permeability. The probe is the first to preserve interspecies affinity and selectivity for both mouse and human CB2R. Extensive cross-validation (FACS, TR-FRET and confocal microscopy) set the stage for CB2R detection in endogenously expressing living cells along with zebrafish larvae. Together, these findings will benefit clinical translatability of CB2R based drugs

    Pre‐breakup extension in the northern North Sea defined by complex strain partitioning and heterogeneous extension rates

    Get PDF
    The early stages of continental rifting are accommodated by the growth of upper‐crustal normal fault systems that are distributed relatively evenly across the rift width. Numerous fault systems define fault arrays , the kinematics of which are poorly understood due to a lack of regional studies drawing on high‐quality subsurface data. Here we investigate the long‐term (~150 Myr) growth of a rift‐related fault array in the East Shetland Basin, northern North Sea, using a regionally extensive subsurface dataset comprising 2D and 3D seismic reflection surveys and 107 boreholes. We show that rift‐related strain during the pre‐Triassic‐to‐Middle Triassic was originally distributed across several sub‐basins. The Middle‐to‐Late Triassic saw a decrease in extension rate (~14 m/Myr) as strain localized in the western part of the basin. Early Jurassic strain initially migrated eastwards, before becoming more diffuse during the main, Middle‐to‐Late Jurassic rift phase. The highest extension rates (~89 m/Myr) corresponded with the main rift event in the East Shetland Basin, before focusing of strain within the rift axis and ultimate abandonment of the East Shetland Basin in the Early Cretaceous. We also demonstrate marked spatial variations in timing and magnitude of slip along‐strike of major fault systems during this protracted rift event. Our results imply that strain migration patterns and extension rates during the initial, pre‐breakup phase of continental rifting may be more complex than previously thought; this reflects temporal and spatial changes in both thermal and mechanical properties of the lithosphere, in addition to varying extension rates

    Evolution of the Southwest Indian Ridge from 55°45′E to 62°E : changes in plate-boundary geometry since 26 Ma

    Get PDF
    Author Posting. © American Geophysical Union, 2007. This article is posted here by permission of American Geophysical Union for personal use, not for redistribution. The definitive version was published in Geochemistry Geophysics Geosystems 8 (2007): Q06022, doi:10.1029/2006GC001559.From 55°45′E to 58°45′E and from 60°30′E to 62°00′E, the ultraslow-spreading Southwest Indian Ridge (SWIR) consists of magmatic spreading segments separated by oblique amagmatic spreading segments, transform faults, and nontransform discontinuities. Off-axis magnetic and multibeam bathymetric data permit investigation of the evolution of this part of the SWIR. Individual magmatic segments show varying magnitudes and directions of asymmetric spreading, which requires that the shape of the plate boundary has changed significantly over time. In particular, since 26 Ma the Atlantis II transform fault grew by 90 km to reach 199 km, while a 45-km-long transform fault at 56°30′E shrank to become an 11 km offset nontransform discontinuity. Conversely, an oblique amagmatic segment at the center of a first-order spreading segment shows little change in orientation with time. These changes are consistent with the clockwise rotation of two ~450-km-wide first-order spreading segments between the Gallieni and Melville transform faults (52–60°E) to become more orthogonal to spreading. We suggest that suborthogonal first-order spreading segments reflect a stable configuration for mid-ocean ridges that maximizes upwelling rates in the asthenospheric mantle and results in a hotter and weaker ridge-axis that can more easily accommodate seafloor spreading.Funding for this work came from a JOI-Schlanger Fellowship to Baines and NSF grant 0352054 to Cheadle and John

    Excessive substance use in bipolar disorder is associated with impaired functioning rather than clinical characteristics, a descriptive study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is a strong association between bipolar disorder (BD) and substance use disorder (SUD). The clinical and functional correlates of SUD in BD are still unclear and little is known about the role of excessive substance use that does not meet SUD criteria. Thus, the aims of the current study were to investigate lifetime rates of illicit substance use in BD relative to the normal population and if there are differences in clinical and functional features between BD patients with and without excessive substance use.</p> <p>Methods</p> <p>125 consecutively recruited BD in- and outpatients from the Oslo University Hospitals and 327 persons randomly drawn from the population in Oslo, Norway participated. Clinical and functional variables were assessed. Excessive substance use was defined as DSM-IV SUD and/or excessive use according to predefined criteria.</p> <p>Results</p> <p>The rate of lifetime illicit substance use was significantly higher among patients compared to the reference population (OR = 3.03, CI = 1.9-4.8, p < .001). Patients with excessive substance use (45% of total) had poorer educational level, occupational status, GAF-scores and medication compliance, with a trend towards higher suicidality rates, compared to patients without. There were no significant group differences in current symptom levels or disease course between groups.</p> <p>Conclusion</p> <p>The percentage of patients with BD that had tried illicit substances was significantly higher than in the normal population. BD patients with excessive substance use clearly had impaired functioning, but not a worse course of illness compared to patients without excessive substance use. An assessment of substance use beyond SUD criteria in BD is clinically relevant.</p

    A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies

    A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies
    corecore