696 research outputs found

    Patterned growth of InGaN/GaN quantum wells on freestanding GaN grating by molecular beam epitaxy

    Get PDF
    We report here the epitaxial growth of InGaN/GaN quantum wells on freestanding GaN gratings by molecular beam epitaxy (MBE). Various GaN gratings are defined by electron beam lithography and realized on GaN-on-silicon substrate by fast atom beam etching. Silicon substrate beneath GaN grating region is removed from the backside to form freestanding GaN gratings, and the patterned growth is subsequently performed on the prepared GaN template by MBE. The selective growth takes place with the assistance of nanoscale GaN gratings and depends on the grating period P and the grating width W. Importantly, coalescences between two side facets are realized to generate epitaxial gratings with triangular section. Thin epitaxial gratings produce the promising photoluminescence performance. This work provides a feasible way for further GaN-based integrated optics devices by a combination of GaN micromachining and epitaxial growth on a GaN-on-silicon substrate

    Assessing Matched Normal and Tumor Pairs in Next-Generation Sequencing Studies

    Get PDF
    Next generation sequencing technology has revolutionized the study of cancers. Through matched normal-tumor pairs, it is now possible to identify genome-wide germline and somatic mutations. The generation and analysis of the data requires rigorous quality checks and filtering, and the current analytical pipeline is constantly undergoing improvements. We noted however that in analyzing matched pairs, there is an implicit assumption that the sequenced data are matched, without any quality check such as those implemented in association studies. There are serious implications in this assumption as identification of germline and rare somatic variants depend on the normal sample being the matched pair. Using a genetics concept on measuring relatedness between individuals, we demonstrate that the matchedness of tumor pairs can be quantified and should be included as part of a quality protocol in analysis of sequenced data. Despite the mutation changes in cancer samples, matched tumor-normal pairs are still relatively similar in sequence compared to non-matched pairs. We demonstrate that the approach can be used to assess the mutation landscape between individuals

    Improved Measurements of Partial Rate Asymmetry in B -> h h Decays

    Full text link
    We report improved measurements of the partial rate asymmetry (Acp) in B -> h h decays with 140fb^-1 of data collected with the Belle detector at the KEKB e+e- collider. Here h stands for a charged or neutral pion or kaon and in total five decay modes are included: K-+ pi+-, K0s pi-+, K-+ pi0, pi-+ pi0 and K0s pi0. The flavor of the last decay mode is determined from the accompanying B meson. Using a data sample 4.7 times larger than that of our previous measurement, we find Acp(K-+ pi+-) -0.088+-0.035+-0.013, 2.4 sigma from zero. Results for other decay modes are also presented.Comment: 9 pages, 1 figur

    Search for CP violation in the decay B0->D*+-D-+

    Get PDF
    We report a search for CP-violating asymmetry in B0 -> D*+- D-+ decays. The analysis employs two methods of B0 reconstruction: full and partial. In the full reconstruction method all daughter particles of the B0 are required to be detected; the partial reconstruction technique requires a fully reconstructed D- and only a slow pion from the D*+ -> D0 pi_slow+ decay. From a fit to the distribution of the time interval corresponding to the distance between two B meson decay points we calculate the CP-violating parameters and find the significance of nonzero CP asymmetry to be 2.7 standard deviations.Comment: 4 pages, 3 figure

    Evaluation of the efficacy of dentin hypersensitivity treatments - a systematic review and follow-up analysis

    Get PDF
    OBJECTIVES: To compare the treatments used to treat dentin hypersensitivity (DH), based on its efficacy and effect duration. METHODS: Medline/PubMed, Cochrane Library, EMBASE, and ClinicalTrials were searched for articles published between January 1st , 2008 and November 14th , 2018, in English, Portuguese or Spanish, reporting clinical trials, completed and with results. This systematic review protocol was registered in PROSPERO, number CRD42019121986. RESULTS: 74 randomized clinical trials were included in the systematic review, reporting patients from 16 to 65 years old, with a clinical diagnosis of DH, that evaluate the efficacy of a desensitizing product, compared to pre-treatment, used the evaporative method stimulation and the visual analogue scale. These studies evaluated 5366 patients and at least 9167 teeth. Seven follow-up periods were considered corresponding to an immediate, medium or long-time effect. 66 studies were included in the quantitative synthesis. Glutaraldehyde with HEMA, glass ionomer cements and Laser present significant immediate (until 7 days) DH reduction. Medium term (until 1 month) reduction was observed in stannous fluoride, glutaraldehyde with HEMA, hydroxyapatite, glass ionomer cements and Laser groups. Finally, long term significant reduction was seen at potassium nitrate, arginine, glutaraldehyde with HEMA, hydroxyapatite, adhesive systems, glass ionomer cements, and LASER. CONCLUSIONS: All active ingredients show efficacy in DH reduction in different follow-up times. Only in-office treatments are effective in immediate DH reduction, maintaining its efficacy over time. For long time effects, at home treatments can also be used. More standardized evaluation protocols should be implemented to increase the robustly of the results.info:eu-repo/semantics/publishedVersio

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Measurement of the Forward-Backward Asymmetry in the B -> K(*) mu+ mu- Decay and First Observation of the Bs -> phi mu+ mu- Decay

    Get PDF
    We reconstruct the rare decays B+→K+μ+μ−B^+ \to K^+\mu^+\mu^-, B0→K∗(892)0μ+μ−B^0 \to K^{*}(892)^0\mu^+\mu^-, and Bs0→ϕ(1020)μ+μ−B^0_s \to \phi(1020)\mu^+\mu^- in a data sample corresponding to 4.4fb−14.4 {\rm fb^{-1}} collected in ppˉp\bar{p} collisions at s=1.96TeV\sqrt{s}=1.96 {\rm TeV} by the CDF II detector at the Fermilab Tevatron Collider. Using 121±16121 \pm 16 B+→K+μ+μ−B^+ \to K^+\mu^+\mu^- and 101±12101 \pm 12 B0→K∗0μ+μ−B^0 \to K^{*0}\mu^+\mu^- decays we report the branching ratios. In addition, we report the measurement of the differential branching ratio and the muon forward-backward asymmetry in the B+B^+ and B0B^0 decay modes, and the K∗0K^{*0} longitudinal polarization in the B0B^0 decay mode with respect to the squared dimuon mass. These are consistent with the theoretical prediction from the standard model, and most recent determinations from other experiments and of comparable accuracy. We also report the first observation of the Bs0→ϕμ+μ−decayandmeasureitsbranchingratioB^0_s \to \phi\mu^+\mu^- decay and measure its branching ratio {\mathcal{B}}(B^0_s \to \phi\mu^+\mu^-) = [1.44 \pm 0.33 \pm 0.46] \times 10^{-6}using using 27 \pm 6signalevents.Thisiscurrentlythemostrare signal events. This is currently the most rare B^0_s$ decay observed.Comment: 7 pages, 2 figures, 3 tables. Submitted to Phys. Rev. Let

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore