753 research outputs found

    Innovative moments and poor outcome in narrative therapy

    Get PDF
    To analyse a poor outcome case of narrative therapy with a woman victim of intimate violence. Method: The Innovative Moments Coding System: version 1 was applied to all sessions to track the innovative moments (i-moments) in the therapeutic process. I moments are the narrative details that occur in psychotherapeutic conversations that are outside the influence of the problematic narrative. This research aims to describe the processes involved in the stability of meanings in psychotherapy through a dialogical approach to meaning making. Findings: Contrarily to what usually occurs in good outcome cases, re-conceptualization i-moments are absent. Moreover, two specific types of i-moments emerged with higher duration: reflection and protest. Qualitative analysis showed that the potential meanings of these i-moments were surpassed by a return to the problematic narrative. Conclusion: The therapeutic stability seems to be maintained by a systematic return to the problematic narrative after the emergence of novelties. This process was referred from a dialogical perspective as a mutual in-feeding of voices, one that emerges in the i-moment and another one that supports the problematic narrative, which is maintained by an oscillation between these two types of voices during therapy.This article was supported by the Portuguese Foundation for Science and Technology (FCT), by the Grant PTDC/PSI/72846/2006 (Narrative Processes in Psychotherapy, 2007-2010) and by the PhD Grant SFRH/BD/16995/2004

    A Sweet Killer: Mesoporous Polysaccharide Confined Silver Nanoparticles for Antibacterial Applications

    Get PDF
    Silver nanoparticles (AgNP) confined within porous starch have been prepared in a simple, green and efficient manner, utilising the nanoporous structure of predominantly mesoporous starch (MS) to act as nanoparticle stabiliser, support and reducing surface. MS/AgNP materials present high surface areas (SBET > 150 m2 g−1) and mesopore volumes (Vmeso > 0.45 cm3 g−1). The interaction of the AgNP precursor and forming nanoparticle nuclei with the mesoporous domains of the porous polysaccharide, direct porosity to increasingly narrower and more defined pore size distributions, indicative of a degree of cooperative assembly. Transmission electron microscopy images indicated the presence of spherical AgNP of a size reflective of the porous polysaccharide mesopore diameter (e.g., 5–25 nm), whilst XPS analysis confirmed the metallic Ag0 state. Materials were prepared at relatively low Ag loadings (<0.18 mmol g−1), demonstrating excellent antimicrobial activity in solid and liquid phase testing against Gram negative (E. coli) and positive (S. aureus) model bacteria. The resulting materials are biocompatible and present a useful solid porous carbohydrate-based polymer vehicle to control the AgNP size regime and facilitate transference to a biological environment

    The processing, properties and use of the pyrotechnic mixture-titanium subhydride/potassium perchlorate

    Full text link
    Development of this pyrotechnic occurred because of the need for a static insensitive material to meet personnel safety requirements and related system safety issues in nuclear weapon energetic material component designs. Ti subhydride materials are made by the thermal dehydrding of commercial Ti hydride powder to the desired equivalent hydrogen composition in the Ti lattice. These Ti subhydrides, when blended with K perchlorate, meet the static insensitivity requirement of not being initiated from an equivalent human body electrostatic discharge. Individual material and blend qualification requirements provide a reproducible material from lot to lot. These pyrotechnic formulations meet the high reliability requirements (0.9995) for initiation and performance parameters and have the necessary stability and compatibility to meet long lived requirements of more than 25 years. Various experiences and problems are also discussed that have led to a mature technology for Ti subhydride/K perchlorate during its use in energetic material component designs

    Rms-flux relation of Cyg X-1 with RXTE: dipping and nondipping cases

    Full text link
    The rms (root mean square) variability is the parameter for understanding the emission temporal properties of X-ray binaries (XRBs) and active galactic nuclei (AGN). The rms-flux relation with Rossi X-ray Timing Explorer (RXTE) data for the dips and nondip of black hole Cyg X-1 has been investigated in this paper. Our results show that there exist the linear rms-flux relations in the frequency range 0.1-10 Hz for the dipping light curve. Moreover, this linear relation still remains during the nondip regime, but with the steeper slope than that of the dipping case in the low energy band. For the high energy band, the slopes of the dipping and nondipping cases are hardly constant within errors. The explanations of the results have been made by means of the ``Propagating Perturbation'' model of Lyubarskii (1997).Comment: 15 pages, 12 figures, Accepted for publication in Astrophysics & Space Scienc

    Precambrian non-marine stromatolites in alluvial fan deposits, the Copper Harbor Conglomerate, upper Michigan

    Full text link
    Laminated cryptalgal carbonates occur in the Precambrian Copper Harbor Conglomerate of northern Michigan, which was deposited in the Keweenawan Trough, an aborted proto-oceanic rift. This unit is composed of three major facies deposited by braided streams on a large alluvial-fan complex. Coarse clastics were deposited in braided channels, predominantly as longitudinal bars, whereas cross-bedded sandstones were deposited by migrating dunes or linguoid bars. Fine-grained overbank deposits accumulated in abandoned channels. Gypsum moulds and carbonate-filled cracks suggest an arid climate during deposition. Stromatolites interstratified with these clastic facies occur as laterally linked drapes over cobbles, as laterally linked contorted beds in mudstone, as oncolites, and as poorly developed mats in coarse sandstones. Stromatolites also are interbedded with oolitic beds and intraclastic conglomerates. Stromatolitic microstructure consists of alternating detrital and carbonate laminae, and open-space structures. Radial-fibrous calcite fans are superimposed on the laminae. The laminae are interpreted as algal in origin, whereas the origin of the radial fibrous calcite is problematic. The stromatolites are inferred to have grown in lakes which occupied abandoned channels on the fan surface. Standing water on a permeable alluvial fan in an arid climate requires a high water table maintained by high precipitation, or local elevation of the water table, possibly due to the close proximity of a lake. Occurrence of stromatolites in the upper part of the Copper Harbor Conglomerate near the base of the lacustrine Nonesuch Shale suggests that these depositional sites may have been near the Nonesuch Lake.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/72022/1/j.1365-3091.1983.tb00713.x.pd

    Clinical indicators for common paediatric conditions: processes, provenance and products of the CareTrack Kids study

    Get PDF
    BACKGROUND:In order to determine the extent to which care delivered to children is appropriate (in line with evidence-based care and/or clinical practice guidelines (CPGs)) in Australia, we developed a set of clinical indicators for 21 common paediatric medical conditions for use across a range of primary, secondary and tertiary healthcare practice facilities. METHODS:Clinical indicators were extracted from recommendations found through systematic searches of national and international guidelines, and formatted with explicit criteria for inclusion, exclusion, time frame and setting. Experts reviewed the indicators using a multi-round modified Delphi process and collaborative online wiki to develop consensus on what constituted appropriate care. RESULTS:From 121 clinical practice guidelines, 1098 recommendations were used to draft 451 proposed appropriateness indicators. In total, 61 experts (n = 24 internal reviewers, n = 37 external reviewers) reviewed these indicators over 40 weeks. A final set of 234 indicators resulted, from which 597 indicator items were derived suitable for medical record audit. Most indicator items were geared towards capturing information about under-use in healthcare (n = 551, 92%) across emergency department (n = 457, 77%), hospital (n = 450, 75%) and general practice (n = 434, 73%) healthcare facilities, and based on consensus level recommendations (n = 451, 76%). The main reason for rejecting indicators was 'feasibility' (likely to be able to be used for determining compliance with 'appropriate care' from medical record audit). CONCLUSION:A set of indicators was developed for the appropriateness of care for 21 paediatric conditions. We describe the processes (methods), provenance (origins and evolution of indicators) and products (indicator characteristics) of creating clinical indicators within the context of Australian healthcare settings. Developing consensus on clinical appropriateness indicators using a Delphi approach and collaborative online wiki has methodological utility. The final indicator set can be used by clinicians and organisations to measure and reflect on their own practice.Louise K. Wiles, Tamara D. Hooper, Peter D. Hibbert, Charlotte Molloy, Les White ... Helena Williams ... et al

    Search for direct production of charginos and neutralinos in events with three leptons and missing transverse momentum in √s = 7 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for the direct production of charginos and neutralinos in final states with three electrons or muons and missing transverse momentum is presented. The analysis is based on 4.7 fb−1 of proton–proton collision data delivered by the Large Hadron Collider and recorded with the ATLAS detector. Observations are consistent with Standard Model expectations in three signal regions that are either depleted or enriched in Z-boson decays. Upper limits at 95% confidence level are set in R-parity conserving phenomenological minimal supersymmetric models and in simplified models, significantly extending previous results
    corecore