203 research outputs found

    ArDM: first results from underground commissioning

    Full text link
    The Argon Dark Matter experiment is a ton-scale double phase argon Time Projection Chamber designed for direct Dark Matter searches. It combines the detection of scintillation light together with the ionisation charge in order to discriminate the background (electron recoils) from the WIMP signals (nuclear recoils). After a successful operation on surface at CERN, the detector was recently installed in the underground Laboratorio Subterr\'aneo de Canfranc, and the commissioning phase is ongoing. We describe the status of the installation and present first results from data collected underground with the detector filled with gas argon at room temperature.Comment: 6 pages, 3 figures, Light Detection In Noble Elements (LIDINE 2013

    Status of the ArDM Experiment: First results from gaseous argon operation in deep underground environment

    Full text link
    The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful operation on surface at CERN, the detector has been deployed underground and is presently commissioned at the Canfranc Underground Laboratory (LSC). In this paper, we describe the status of the installation and present first results on data collected in gas phase.Comment: 21 pages, 20 figure

    Childhood Absence Epilepsy with Tonic-Clonic Seizures and Electroencephalogram 3–4-Hz Spike and Multispike–Slow Wave Complexes: Linkage to Chromosome 8q24

    Get PDF
    SummaryChildhood absence epilepsy (CAE), a common form of idiopathic generalized epilepsy, accounts for 5%–15% of childhood epilepsies. To map the chromosomal locus of persisting CAE, we studied the clinical and electroencephalographic traits of 78 members of a five-generation family from Bombay, India. The model-free affected–pedigree member method was used during initial screening with chromosome 6p, 8q, and 1p microsatellites, and only individuals with absence seizures and/or electroencephalogram 3–4-Hz spike– and multispike–slow wave complexes were considered to be affected. Significant P values of .00000–.02 for several markers on 8q were obtained. Two-point linkage analysis, assuming autosomal dominant inheritance with 50% penetrance, yielded a maximum LOD score (Zmax) of 3.6 for D8S502. No other locus in the genome achieved a significant Zmax. For five smaller multiplex families, summed Zmax was 2.4 for D8S537 and 1.7 for D8S1761. Haplotypes composed of the same 8q24 microsatellites segregated with affected members of the large family from India and with all five smaller families. Recombinations positioned the CAE gene in a 3.2-cM interval

    The ArDM experiment

    Get PDF
    The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, including a 3 l prototype developed to test the charge readout system.Comment: Proceedings of the Epiphany 2010 Conference, to be published in Acta Physica Polonica

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    The Higgs Working Group: Summary Report 2003

    Full text link
    Theoretical progress in Higgs boson production and background processes is discussed with particular emphasis on QCD corrections at and beyond next-to-leading order as well as next-to-leading order electroweak corrections. The residual theoretical uncertainties of the investigated processes are estimated in detail. Moreover, recent investigations of the MSSM Higgs sector and other extensions of the SM Higgs sector are presented. The potential of the LHC and a high-energy linear e+e- collider for the measurement of Higgs couplings is analyzed.Comment: 169 pages, Proceedings 3rd Les Houches Workshop: Physics at TeV Colliders, Les Houches, France, 26 May - 6 Jun 200

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe

    CMS Data Processing Workflows during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe
    corecore