62 research outputs found

    Automated bone marrow analysis using the CD4000 automated haematology analyser

    Get PDF
    At present, bone marrow analysis is performed microscopically, but is time consuming and labour intensive. No automated methods have been successfully applied to classification of bone marrows cells because automated blood cell analysers have been incapable of identifying erythroblasts. The present study was designed to evaluate automated analysis of bone marrow aspirates with the CELL-DYN 4000 (CD4000) haematology analyser, which enables automated determination of erythroblast counts in both the normal mode (haemolytic time; 11.5s) and the resistant RBC mode (34.0s). The percentages of subpopulations including lymphocytes, neutrophils and erythroblasts were obtained with the CD4000, and as a reference, differential counts by microscopic observation of May–Grünwald–Giesa-stained films of bone marrow aspirates were performed (n=98). Significant correlations (P < 0.01) between the results obtained with the two methods were observed for total nucleated cell count and lymphocytes, neutrophils, erythroblasts and myeloid/erythroid (M/E) ratio. However, there were biases in the average percentages of erythroblasts, lymphocytes and M/E ratio obtained using the normal mode with the CD4000 toward values lower than those obtained with the microscopic method. Using the RBC resistant mode with the CD4000, the average percentages of erythroblasts, lymphocytes and M/E ratio approximated those obtained with the microscopic method. In conclusion, the CD4000 in resistant RBC mode is more useful for analysis of bone marrow aspirates than is the normal mode, because the former better approximates the M/E ratio than the latter

    Molecular imaging of hypoxia with radiolabelled agents

    Get PDF
    Tissue hypoxia results from an inadequate supply of oxygen (O2) that compromises biological functions. Structural and functional abnormalities of the tumour vasculature together with altered diffusion conditions inside the tumour seem to be the main causes of tumour hypoxia. Evidence from experimental and clinical studies points to a role for tumour hypoxia in tumour propagation, resistance to therapy and malignant progression. This has led to the development of assays for the detection of hypoxia in patients in order to predict outcome and identify patients with a worse prognosis and/or patients that would benefit from appropriate treatments. A variety of invasive and non-invasive approaches have been developed to measure tumour oxygenation including oxygen-sensitive electrodes and hypoxia marker techniques using various labels that can be detected by different methods such as positron emission tomography (PET), single photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), autoradiography and immunohistochemistry. This review aims to give a detailed overview of non-invasive molecular imaging modalities with radiolabelled PET and SPECT tracers that are available to measure tumour hypoxia

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Search for single production of vector-like quarks decaying into Wb in pp collisions at s=8\sqrt{s} = 8 TeV with the ATLAS detector

    Get PDF

    Measurements of top-quark pair differential cross-sections in the eμe\mu channel in pppp collisions at s=13\sqrt{s} = 13 TeV using the ATLAS detector

    Get PDF

    Measurement of the charge asymmetry in top-quark pair production in the lepton-plus-jets final state in pp collision data at s=8TeV\sqrt{s}=8\,\mathrm TeV{} with the ATLAS detector

    Get PDF

    Measurement of the W boson polarisation in ttˉt\bar{t} events from pp collisions at s\sqrt{s} = 8 TeV in the lepton + jets channel with ATLAS

    Get PDF

    Measurement of the bbb\overline{b} dijet cross section in pp collisions at s=7\sqrt{s} = 7 TeV with the ATLAS detector

    Get PDF
    corecore