1,732 research outputs found

    An Examination of Backgrounds to Early-Run Minimum-Bias Events in ATLAS at the LHC

    Get PDF
    The initial parts of the Large Hadron Collider (LHC) run will be a source of critical information - about the ATLAS detector and about the physics of pppp collisions at sqrts=14sqrt{s} = 14 TeV, including parton distribution evolution and the cross-sections of sigmappsigma_{pp}. The accelerator itself will be the source of some detector interest, as we have a first look at what have so far been speculations on the quality of the vacuum in the experimental insertion, and the cleanliness of the beam from the accelerator. The shakedown period, with its low beam squeeze, low luminosity, and undemanding trigger menus, will be of great interest, avoiding the pileup and radiation levels that will arrive with higher luminosity -- making it an important opportunity to investigate minimum-bias events in relative isolation. For the short lifetime of the Minimum Bias Trigger Scintillators (MBTS), which are expected to fail within a few months of running, they will aid in discriminating the minimum bias signal of inelastic non-single-diffractive pppp collisions. Using single- or double-coincidence signatures, the MBTS system and other trigger and analysis strategies attempt to avoid triggering on otherwise empty bunch crossings and eliminate the effects of beam-gas collisions and beam-halo effects which would lead these spurious triggers that would reduce the general minimum-bias trigger efficiency. An examination of the effects of beam halo and beam -gas interactions on the minimum-bias trigger response is made. The signatures of the beam halo and beam gas are examined from the standard ATLAS tracking reconstruction

    Design guide for high pressure oxygen systems

    Get PDF
    A repository for critical and important detailed design data and information, hitherto unpublished, along with significant data on oxygen reactivity phenomena with metallic and nonmetallic materials in moderate to very high pressure environments is documented. This data and information provide a ready and easy to use reference for the guidance of designers of propulsion, power, and life support systems for use in space flight. The document is also applicable to designs for industrial and civilian uses of high pressure oxygen systems. The information presented herein are derived from data and design practices involving oxygen usage at pressures ranging from about 20 psia to 8000 psia equal with thermal conditions ranging from room temperatures up to 500 F

    MB 700 Anthropology for Christian Mission

    Get PDF
    Textbook: Cultural Anthropology: An Applied Perspective, fifth edition by Gary Ferraro Readings: Anthropology and Christian Mission: A Reader, Darrell Whiteman (ed.)Customs and Cultures by Eugene Nidahttps://place.asburyseminary.edu/syllabi/2521/thumbnail.jp

    The effects of continuous positive airway pressure therapy withdrawal on cardiac repolarization: data from a randomized controlled trial†

    Get PDF
    Aims The preliminary evidence supports an association between obstructive sleep apnoea (OSA), disturbed cardiac repolarization, and consequent cardiac dysrhythmias. The aim of the current trial was to assess the effects of continuous positive airway pressure (CPAP) therapy withdrawal on the measures of cardiac repolarization in patients with OSA. Methods and results Forty-one OSA patients established on CPAP treatment were randomized to either CPAP withdrawal (subtherapeutic CPAP) or continue therapeutic CPAP for 2 weeks. Polysomnography was performed, and indices of cardiac repolarization (QTc, TpTec intervals) and dispersion of repolarization (TpTe/QT ratio) were derived from 12-lead electrocardiography (ECG) at baseline and 2 weeks. Continuous positive airway pressure withdrawal led to a recurrence of OSA. Compared with therapeutic CPAP, subtherapeutic CPAP for 2 weeks was associated with a significant increase in the length of the QTc and TpTec intervals (mean difference between groups 21.4 ms, 95% CI 11.3-1.6 ms, P < 0.001 and 14.4 ms, 95% CI 7.2-21.5 ms, P < 0.001, respectively) and in the TpTe/QT ratio (mean difference between groups 0.02, 95% CI 0.00-0.03, P = 0.020). There was a statistically significant correlation between the change in apnoea/hypopnoea index (AHI) from baseline, and both the change in the QTc interval and the TpTec interval (r = 0.60, 95% CI 0.36-0.77, P < 0.001 and r = 0.45, 95% CI 0.17-0.67, P = 0.003, n = 41, respectively). Conclusion Continuous positive airway pressure withdrawal is associated with the prolongation of the QTc and TpTec intervals and TpTe/QT ratio, which may provide a possible mechanistic link between OSA, cardiac dysrhythmias, and thus sudden cardiac deat

    High temperature GaAs X-ray detectors

    Get PDF
    Two GaAs p+-i-n+ mesa X-ray photodiodes were characterized for their electrical and photon counting X-ray spectroscopic performance over the temperature range of 100 °C to –20 °C. The devices had 10 μm thick i layers with different diameters: 200 μm (D1) and 400 μm (D2). The electrical characterization included dark current and capacitance measurements at internal electric field strengths of up to 50 kV/cm. The determined properties of the two devices were compared with previously reported results that were made with a view to informing the future development of photon counting X-ray spectrometers for harsh environments, e.g., X-ray fluorescence spectroscopy of planetary surfaces in high temperature environments. The best energy resolution obtained (Full Width at Half Maximum at 5.9 keV) decreased from 2.00 keV at 100 °C to 0.66 keV at –20 °C for the spectrometer with D1, and from 2.71 keV at 100 °C to 0.71 keV at –20 °C for the spectrometer with D2. Dielectric noise was found to be the dominant source of noise in the spectra, apart from at high temperatures and long shaping times, where the main source of photopeak broadening was found to be the white parallel noise

    Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC

    Get PDF
    The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at centre-of-mass energies of sqrt(s) = 900 GeV and 7 TeV collected during 2009 and 2010. Then, using the decay of K_s and Lambda particles, the calorimeter response to specific types of particles (positively and negatively charged pions, protons, and anti-protons) is measured and compared to the Monte Carlo predictions. Finally, the jet energy scale uncertainty is determined by propagating the response uncertainty for single charged and neutral particles to jets. The response uncertainty is 2-5% for central isolated hadrons and 1-3% for the final calorimeter jet energy scale.Comment: 24 pages plus author list (36 pages total), 23 figures, 1 table, submitted to European Physical Journal

    Measurement of χ c1 and χ c2 production with s√ = 7 TeV pp collisions at ATLAS

    Get PDF
    The prompt and non-prompt production cross-sections for the χ c1 and χ c2 charmonium states are measured in pp collisions at s√ = 7 TeV with the ATLAS detector at the LHC using 4.5 fb−1 of integrated luminosity. The χ c states are reconstructed through the radiative decay χ c → J/ψγ (with J/ψ → μ + μ −) where photons are reconstructed from γ → e + e − conversions. The production rate of the χ c2 state relative to the χ c1 state is measured for prompt and non-prompt χ c as a function of J/ψ transverse momentum. The prompt χ c cross-sections are combined with existing measurements of prompt J/ψ production to derive the fraction of prompt J/ψ produced in feed-down from χ c decays. The fractions of χ c1 and χ c2 produced in b-hadron decays are also measured

    Evidence for the h_b(1P) meson in the decay Upsilon(3S) --> pi0 h_b(1P)

    Get PDF
    Using a sample of 122 million Upsilon(3S) events recorded with the BaBar detector at the PEP-II asymmetric-energy e+e- collider at SLAC, we search for the hb(1P)h_b(1P) spin-singlet partner of the P-wave chi_{bJ}(1P) states in the sequential decay Upsilon(3S) --> pi0 h_b(1P), h_b(1P) --> gamma eta_b(1S). We observe an excess of events above background in the distribution of the recoil mass against the pi0 at mass 9902 +/- 4(stat.) +/- 2(syst.) MeV/c^2. The width of the observed signal is consistent with experimental resolution, and its significance is 3.1sigma, including systematic uncertainties. We obtain the value (4.3 +/- 1.1(stat.) +/- 0.9(syst.)) x 10^{-4} for the product branching fraction BF(Upsilon(3S)-->pi0 h_b) x BF(h_b-->gamma eta_b).Comment: 8 pages, 4 postscript figures, submitted to Phys. Rev. D (Rapid Communications
    corecore