434 research outputs found

    Second trimester inflammatory and metabolic markers in women delivering preterm with and without preeclampsia.

    Get PDF
    ObjectiveInflammatory and metabolic pathways are implicated in preterm birth and preeclampsia. However, studies rarely compare second trimester inflammatory and metabolic markers between women who deliver preterm with and without preeclampsia.Study designA sample of 129 women (43 with preeclampsia) with preterm delivery was obtained from an existing population-based birth cohort. Banked second trimester serum samples were assayed for 267 inflammatory and metabolic markers. Backwards-stepwise logistic regression models were used to calculate odds ratios.ResultsHigher 5-ι-pregnan-3β,20ι-diol disulfate, and lower 1-linoleoylglycerophosphoethanolamine and octadecanedioate, predicted increased odds of preeclampsia.ConclusionsAmong women with preterm births, those who developed preeclampsia differed with respect metabolic markers. These findings point to potential etiologic underpinnings for preeclampsia as a precursor to preterm birth

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Chronic disease management programmes for adults with asthma (intervention Review)

    Get PDF
    BACKGROUND: The burden of asthma on patients and healthcare systems is substantial. Interventions have been developed to overcome difficulties in asthma management. These include chronic disease management programmes, which are more than simple patient education, encompassing a set of coherent interventions that centre on the patients' needs, encouraging the co-ordination and integration of health services provided by a variety of healthcare professionals, and emphasising patient self-management as well as patient education. OBJECTIVES: To evaluate the effectiveness of chronic disease management programmes for adults with asthma. SEARCH METHODS: Cochrane Central Register of Controlled Trials (CENTRAL), Cochrane Effective Practice and Organisation of Care (EPOC) Group Specialised Register, MEDLINE (MEDLINE In-Process and Other Non-Indexed Citations), EMBASE, CINAHL, and PsycINFO were searched up to June 2014. We also handsearched selected journals from 2000 to 2012 and scanned reference lists of relevant reviews. SELECTION CRITERIA: We included individual or cluster-randomised controlled trials, non-randomised controlled trials, and controlled before-after studies comparing chronic disease management programmes with usual care in adults over 16 years of age with a diagnosis of asthma. The chronic disease management programmes had to satisfy at least the following five criteria: an organisational component targeting patients; an organisational component targeting healthcare professionals or the healthcare system, or both; patient education or self-management support, or both; active involvement of two or more healthcare professionals in patient care; a minimum duration of three months. DATA COLLECTION AND ANALYSIS: After an initial screen of the titles, two review authors working independently assessed the studies for eligibility and study quality; they also extracted the data. We contacted authors to obtain missing information and additional data, where necessary. We pooled results using the random-effects model and reported the pooled mean or standardised mean differences (SMDs). MAIN RESULTS: A total of 20 studies including 81,746 patients (median 129.5) were included in this review, with a follow-up ranging from 3 to more than 12 months. Patients' mean age was 42.5 years, 60% were female, and their asthma was mostly rated as moderate to severe. Overall the studies were of moderate to low methodological quality, because of limitations in their design and the wide confidence intervals for certain results.Compared with usual care, chronic disease management programmes resulted in improvements in asthma-specific quality of life (SMD 0.22, 95% confidence interval (CI) 0.08 to 0.37), asthma severity scores (SMD 0.18, 95% CI 0.05 to 0.30), and lung function tests (SMD 0.19, 95% CI 0.09 to 0.30). The data for improvement in self-efficacy scores were inconclusive (SMD 0.51, 95% CI -0.08 to 1.11). Results on hospitalisations and emergency department or unscheduled visits could not be combined in a meta-analysis because the data were too heterogeneous; results from the individual studies were inconclusive overall. Only a few studies reported results on asthma exacerbations, days off work or school, use of an action plan, and patient satisfaction. Meta-analyses could not be performed for these outcomes. AUTHORS' CONCLUSIONS: There is moderate to low quality evidence that chronic disease management programmes for adults with asthma can improve asthma-specific quality of life, asthma severity, and lung function tests. Overall, these results provide encouraging evidence of the potential effectiveness of these programmes in adults with asthma when compared with usual care. However, the optimal composition of asthma chronic disease management programmes and their added value, compared with education or self-management alone that is usually offered to patients with asthma, need further investigation

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe

    CMS Data Processing Workflows during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Alignment of the CMS muon system with cosmic-ray and beam-halo muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR(Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Studies of new Higgs boson interactions through nonresonant HH production in the b¯bγγ fnal state in pp collisions at √s = 13 TeV with the ATLAS detector

    Get PDF
    A search for nonresonant Higgs boson pair production in the b ¯bγγ fnal state is performed using 140 fb−1 of proton-proton collisions at a centre-of-mass energy of 13 TeV recorded by the ATLAS detector at the CERN Large Hadron Collider. This analysis supersedes and expands upon the previous nonresonant ATLAS results in this fnal state based on the same data sample. The analysis strategy is optimised to probe anomalous values not only of the Higgs (H) boson self-coupling modifer κλ but also of the quartic HHV V (V = W, Z) coupling modifer κ2V . No signifcant excess above the expected background from Standard Model processes is observed. An observed upper limit µHH < 4.0 is set at 95% confdence level on the Higgs boson pair production cross-section normalised to its Standard Model prediction. The 95% confdence intervals for the coupling modifers are −1.4 < κλ < 6.9 and −0.5 < κ2V < 2.7, assuming all other Higgs boson couplings except the one under study are fxed to the Standard Model predictions. The results are interpreted in the Standard Model efective feld theory and Higgs efective feld theory frameworks in terms of constraints on the couplings of anomalous Higgs boson (self-)interactions

    Commissioning and performance of the CMS pixel tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published verion of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)
    • …
    corecore