152 research outputs found

    Gaia Early Data Release 3: Parallax bias versus magnitude, colour, and position

    Full text link
    Gaia Early Data Release 3 (Gaia EDR3) gives trigonometric parallaxes for nearly 1.5 billion sources. Inspection of the EDR3 data for sources identified as quasars reveals that their parallaxes are biased, that is systematically offset from the expected distribution around zero, by a few tens of microarcsec. We attempt to map the main dependencies of the parallax bias in EDR3. In principle this could provide a recipe for correcting the EDR3 parallaxes. For faint sources the quasars provide the most direct way to estimate parallax bias. In order to extend this to brighter sources and a broader range of colours, we use differential methods based on physical pairs (binaries) and sources in the Large Magellanic Cloud. The functional forms of the dependencies are explored by mapping the systematic differences between EDR3 and DR2 parallaxes. The parallax bias is found to depend in a non-trivial way on (at least) the magnitude, colour, and ecliptic latitude of the source. Different dependencies apply to the five- and six-parameter solutions in EDR3. While it is not possible to derive a definitive recipe for the parallax correction, we give tentative expressions to be used at the researcher's discretion and point out some possible paths towards future improvements.Comment: 32 pages, 30 figures. Submitted to Astronomy & Astrophysics. Revised version where typos in (A.3) have been corrected. For associated code, see https://www.cosmos.esa.int/web/gaia/edr3-code (code was not affected by the typos

    Elucidating halo structure by β decay: βγ from the Li-11 decay

    Get PDF
    4 pages, 2 tables, 1 figure.-- PACS nrs.: 23.40.Hc, 21.10.Pc, 21.60.Cs, 23.20.Lv.New values for the γ ray intensities following the β decay of Li-11 are presented. Special emphasis is put on the determination of the Gamow-Teller transition Li-11 --> Be-11 (1/2(-), 320 keV) to the only bound excited state in Be-11. We show that a shell-model calculation can simultaneously reproduce the half-life of Li-11 and the newly measured branching ratio to the 1/2(-) state provided the Li-11 ground state wave function contains about 50% of s-wave neutron components.Financial support for this study from the Spanish CICyT (Contract AEN94-0833-C02-02) and DGICyT (Contract PB93-263) and Bundesministerium für Forschung und Technologie (contract No. 06DA665I) is gratefully acknowledged.Peer reviewe

    <i>Gaia</i> Data Release 1. Summary of the astrometric, photometric, and survey properties

    Get PDF
    Context. At about 1000 days after the launch of Gaia we present the first Gaia data release, Gaia DR1, consisting of astrometry and photometry for over 1 billion sources brighter than magnitude 20.7. Aims. A summary of Gaia DR1 is presented along with illustrations of the scientific quality of the data, followed by a discussion of the limitations due to the preliminary nature of this release. Methods. The raw data collected by Gaia during the first 14 months of the mission have been processed by the Gaia Data Processing and Analysis Consortium (DPAC) and turned into an astrometric and photometric catalogue. Results. Gaia DR1 consists of three components: a primary astrometric data set which contains the positions, parallaxes, and mean proper motions for about 2 million of the brightest stars in common with the HIPPARCOS and Tycho-2 catalogues – a realisation of the Tycho-Gaia Astrometric Solution (TGAS) – and a secondary astrometric data set containing the positions for an additional 1.1 billion sources. The second component is the photometric data set, consisting of mean G-band magnitudes for all sources. The G-band light curves and the characteristics of ∼3000 Cepheid and RR-Lyrae stars, observed at high cadence around the south ecliptic pole, form the third component. For the primary astrometric data set the typical uncertainty is about 0.3 mas for the positions and parallaxes, and about 1 mas yr−1 for the proper motions. A systematic component of ∼0.3 mas should be added to the parallax uncertainties. For the subset of ∼94 000 HIPPARCOS stars in the primary data set, the proper motions are much more precise at about 0.06 mas yr−1. For the secondary astrometric data set, the typical uncertainty of the positions is ∼10 mas. The median uncertainties on the mean G-band magnitudes range from the mmag level to ∼0.03 mag over the magnitude range 5 to 20.7. Conclusions. Gaia DR1 is an important milestone ahead of the next Gaia data release, which will feature five-parameter astrometry for all sources. Extensive validation shows that Gaia DR1 represents a major advance in the mapping of the heavens and the availability of basic stellar data that underpin observational astrophysics. Nevertheless, the very preliminary nature of this first Gaia data release does lead to a number of important limitations to the data quality which should be carefully considered before drawing conclusions from the data

    Gaia Early Data Release 3. Acceleration of the Solar System from Gaia astrometry

    Get PDF
    Context. Gaia Early Data Release 3 (Gaia EDR3) provides accurate astrometry for about 1.6 million compact (QSO-like) extragalactic sources, 1.2 million of which have the best-quality five-parameter astrometric solutions. Aims: The proper motions of QSO-like sources are used to reveal a systematic pattern due to the acceleration of the solar systembarycentre with respect to the rest frame of the Universe. Apart from being an important scientific result by itself, the acceleration measured in this way is a good quality indicator of the Gaia astrometric solution. Methods: Theeffect of the acceleration was obtained as a part of the general expansion of the vector field of proper motions in vector spherical harmonics (VSH). Various versions of the VSH fit and various subsets of the sources were tried and compared to get the most consistent result and a realistic estimate of its uncertainty. Additional tests with the Gaia astrometric solution were used to get a better idea of the possible systematic errors in the estimate. Results: Our best estimate of the acceleration based on Gaia EDR3 is (2.32 ± 0.16) × 10−10 m s−2 (or 7.33 ±0.51 km s−1 Myr−1) towards α = 269.1° ± 5.4°, δ = −31.6° ± 4.1°, corresponding to a proper motion amplitude of 5.05 ±0.35 μas yr−1. This is in good agreement with the acceleration expected from current models of the Galactic gravitational potential. We expect that future Gaia data releases will provide estimates of the acceleration with uncertainties substantially below 0.1 μas yr−1. Movie is only available at https://www.aanda.or

    Gaia Data Release 1. Astrometry: one billion positions, two million proper motions and parallaxes

    Get PDF
    Context. Gaia Data Release 1 (DR1) contains astrometric results for more than 1 billion stars brighter than magnitude 20.7 based on observations collected by the Gaia satellite during the first 14 months of its operational phase. Aims. We give a brief overview of the astrometric content of the data release and of the model assumptions, data processing, and validation of the results. Methods. For stars in common with the Hipparcos and Tycho-2 catalogues, complete astrometric single-star solutions are obtained by incorporating positional information from the earlier catalogues. For other stars only their positions are obtained, essentially by neglecting their proper motions and parallaxes. The results are validated by an analysis of the residuals, through special validation runs, and by comparison with external data. Results. For about two million of the brighter stars (down to magnitude ∼11.5) we obtain positions, parallaxes, and proper motions to Hipparcos-type precision or better. For these stars, systematic errors depending for example on position and colour are at a level of ±0.3 milliarcsecond (mas). For the remaining stars we obtain positions at epoch J2015.0 accurate to ∼10 mas. Positions and proper motions are given in a reference frame that is aligned with the International Celestial Reference Frame (ICRF) to better than 0.1 mas at epoch J2015.0, and non-rotating with respect to ICRF to within 0.03 mas yr−1 . The Hipparcos reference frame is found to rotate with respect to the Gaia DR1 frame at a rate of 0.24 mas yr−1 . Conclusions. Based on less than a quarter of the nominal mission length and on very provisional and incomplete calibrations, the quality and completeness of the astrometric data in Gaia DR1 are far from what is expected for the final mission products. The present results nevertheless represent a huge improvement in the available fundamental stellar data and practical definition of the optical reference frame

    Gaia Data Release 2: The astrometric solution

    Get PDF
    Gaia Data Release 2 (Gaia DR2) contains results for 1693 million sources in the magnitude range 3 to 21 based on observations collected by the European Space Agency Gaia satellite during the first 22 months of its operational phase. We describe the input data, models, and processing used for the astrometric content of Gaia DR2, and the validation of these results performed within the astrometry task. Some 320 billion centroid positions from the pre-processed astrometric CCD observations were used to estimate the five astrometric parameters (positions, parallaxes, and proper motions) for 1332 million sources, and approximate positions at the reference epoch J2015.5 for an additional 361 million mostly faint sources. Special validation solutions were used to characterise the random and systematic errors in parallax and proper motion. For the sources with five-parameter astrometric solutions, the median uncertainty in parallax and position at the reference epoch J2015.5 is about 0.04 mas for bright (G<14 mag) sources, 0.1 mas at G=17 mag, and 0.7 mas at G=20 mag. In the proper motion components the corresponding uncertainties are 0.05, 0.2, and 1.2 mas/yr, respectively. The optical reference frame defined by Gaia DR2 is aligned with ICRS and is non-rotating with respect to the quasars to within 0.15 mas/yr. From the quasars and validation solutions we estimate that systematics in the parallaxes depending on position, magnitude, and colour are generally below 0.1 mas, but the parallaxes are on the whole too small by about 0.03 mas. Significant spatial correlations of up to 0.04 mas in parallax and 0.07 mas/yr in proper motion are seen on small (<1 deg) and intermediate (20 deg) angular scales. Important statistics and information for the users of the Gaia DR2 astrometry are given in the appendices.Includes STFC
    corecore