1,668 research outputs found
Descrição de uma forma autossĂ´mica dominante de sĂndrome de Kabuki por mutação no gene MLL2
Aims: Although there are more than 400 cases of Kabuki syndrome described in the literature, it is believed that this syndrome is under-diagnosed. Most cases occur sporadically, despite cases with autosomal dominant familial transmission being described. Here we describe three cases identified in the same family.
Cases description: A family (mother and two children) was diagnosed with Kabuki syndrome. The three patients show the typical characteristics (facial appearance, musculoskeletal abnormalities, cognitive impairment, growth retardation and peculiar dermatoglyphic pattern) associated with other anomalies described in the syndrome (congenital heart disease and increased susceptibility to infections). Genetic studies revealed a nonsense mutation c.14710 C > T (p.Arg4904X) in the MLL2 gene in the three members of the family.
Conclusions: With the description of another case of familial Kabuki syndrome, the authors wish to illustrate the autosomal dominant inheritance with variable expressivity, which are present in this situation, and to alert to the need for a rigorous clinical and molecular evaluation of the affected patientâs relatives, allowing appropriate genetic counseling
Preseason Training Improves Perception of Fatigue and Recovery From a Futsal Training Session.
Purpose: To compare the posttraining recovery timeline of elite Brazilian futsal athletes before (Pre-PS) and after 10 weeks of the preseason (Post-PS) period of high-intensity technicalâtactical training. Methods: At the start (n = 13) and at the end of the preseason (n = 7), under-20 male futsal players undertook fitness testing for maximal aerobic power, the countermovement jump (CMJ), and the 10-m sprint with change of direction. Furthermore, at both Pre-PS and Post-PS, the players participated in a training session where performance and psychophysiological measures were recorded before, immediately, 3, 24, and 48 hours postsession. The measures included CMJ, 10-m sprint, creatine kinase, Total Quality Recovery Scale, and Brunel Mood Scale. Effect size (ES) analyses compared fitness and posttraining recovery values for each parameter at Pre-PS versus Post-PS. Results: Only trivial ES (â0.02 to 0.11) was evident in maximal aerobic power, CMJ, and 10-m sprint at Post-PS compared with Pre-PS. For the timeline of recovery, only trivial and small ESs were evident for the 10-m sprint (â0.12 to 0.49), though CMJ recovery was improved at 3 hours (0.87) and 48 hours (1.27) at Post-PS and creatine kinase was lower at 48 hours (â1.33) at Post-PS. Perception of recovery was improved in Post-PS at 3 hours (1.50) and 24 hours postsession (0.92). Furthermore, perception of effort was lower immediately after the session (â0.29), fatigue was lower at 3 hours (â0.63), and vigor responses were improved in all postseason assessments (0.59 to 1.13). Conclusion: Despite minimal changes in fitness, preseason training attenuated players' perception of effort and fatigue and improved their recovery profile following a high-intensity technicalâtactical training session
Hybrid Model for the Analysis of Human Gait: A Non-linear Approach
In this work, a generalization of the study of the human gait was made from already
existent models in the literature, like models of Keller and Kockshenev. In this hybrid model, a
strategy of metabolic energy minimization is combined in a race process, with a non-linear
description of the movement of the mass centerâs libration, trying to reproduce the behavior of
the walk-run transition. The results of the experimental data, for different speed regimes, indicate
that the perimeter of the trajectory of the mass center is a relevant quantity in the quantification
of this dynamic. An experimental procedure was put into practice in collaboration with the
research group in Biomedical Engineering, Basic Sciences and Laboratories of the Manuela BeltrĂĄn
University in BogotĂĄ, Colombia
Beyond the required LISA free-fall performance: new LISA pathfinder results down to 20ââÎźHz
In the months since the publication of the first results, the noise performance of LISA Pathfinder has improved because of reduced Brownian noise due to the continued decrease in pressure around the test masses, from a better correction of noninertial effects, and from a better calibration of the electrostatic force actuation. In addition, the availability of numerous long noise measurement runs, during which no perturbation is purposely applied to the test masses, has allowed the measurement of noise with good statistics down to 20ââÎźHz. The Letter presents the measured differential acceleration noise figure, which is at (1.74Âą0.05)ââfmâs^{-2}/sqrt[Hz] above 2 mHz and (6Âą1)Ă10ââfmâs^{-2}/sqrt[Hz] at 20ââÎźHz, and discusses the physical sources for the measured noise. This performance provides an experimental benchmark demonstrating the ability to realize the low-frequency science potential of the LISA mission, recently selected by the European Space Agency
Prevalence and etiology of false normal aEEG recordings in neonatal hypoxic-ischaemic encephalopathy.
BACKGROUND: Amplitude-integrated electroencephalography (aEEG) is a useful tool to determine the severity of neonatal hypoxic-ischemic encephalopathy (HIE). Our aim was to assess the prevalence and study the origin of false normal aEEG recordings based on 85 aEEG recordings registered before six hours of age. METHODS: Raw EEG recordings were reevaluated retrospectively with Fourier analysis to identify and describe the frequency patterns of the raw EEG signal, in cases with inconsistent aEEG recordings and clinical symptoms. Power spectral density curves, power (P) and median frequency (MF) were determined using the raw EEG. In 7 patients non-depolarizing muscle relaxant (NDMR) exposure was found. The EEG sections were analyzed and compared before and after NDMR administration. RESULTS: The reevaluation found that the aEEG was truly normal in 4 neonates. In 3 neonates, high voltage electrocardiographic (ECG) artifacts were found with flat trace on raw EEG. High frequency component (HFC) was found as a cause of normal appearing aEEG in 10 neonates. HFC disappeared while P and MF decreased significantly upon NDMR administration in each observed case. CONCLUSION: Occurrence of false normal aEEG background pattern is relatively high in neonates with HIE and hypothermia. High frequency EEG artifacts suggestive of shivering were found to be the most common cause of false normal aEEG in hypothermic neonates while high voltage ECG artifacts are less common
Precise measurement of the W-boson mass with the CDF II detector
We have measured the W-boson mass MW using data corresponding to 2.2/fb of
integrated luminosity collected in proton-antiproton collisions at 1.96 TeV
with the CDF II detector at the Fermilab Tevatron collider. Samples consisting
of 470126 W->enu candidates and 624708 W->munu candidates yield the measurement
MW = 80387 +- 12 (stat) +- 15 (syst) = 80387 +- 19 MeV. This is the most
precise measurement of the W-boson mass to date and significantly exceeds the
precision of all previous measurements combined
X-ray emission from the Sombrero galaxy: discrete sources
We present a study of discrete X-ray sources in and around the
bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival
Chandra observations with a total exposure of ~200 ks. With a detection limit
of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30
kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler
et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS
observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray
binaries (LMXBs). We quantify the differential luminosity functions (LFs) for
both the detected GC and field LMXBs, whose power-low indices (~1.1 for the
GC-LF and ~1.6 for field-LF) are consistent with previous studies for
elliptical galaxies. With precise sky positions of the GCs without a detected
X-ray source, we further quantify, through a fluctuation analysis, the GC LF at
fainter luminosities down to 1E35 erg/s. The derived index rules out a
faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent
findings in several elliptical galaxies and the bulge of M31. On the other
hand, the 2-6 keV unresolved emission places a tight constraint on the field
LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101
sources in the halo of Sombrero. The presence of these sources cannot be
interpreted as galactic LMXBs whose spatial distribution empirically follows
the starlight. Their number is also higher than the expected number of cosmic
AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray
surveys. We suggest that either the cosmic X-ray background is unusually high
in the direction of Sombrero, or a distinct population of X-ray sources is
present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
- âŚ