290 research outputs found

    Anemia status, hemoglobin concentration and outcome after acute stroke: a cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the setting of an acute stroke, anemia has the potential to worsen brain ischemia, however, the relationship between the entire range of hemoglobin to long-term outcome is not well understood.</p> <p>Methods</p> <p>We examined the association between World Health Organization-defined admission anemia status (hemoglobin<13 in males, <12 g/dl in women) and hemoglobin concentration and 1-year outcome among 859 consecutive patients with acute stroke (ischemic or intracerebral hemorrhage).</p> <p>Results</p> <p>The mean baseline hemoglobin concentration was 13.8 Âą 1.7 g/dl (range 8.1 - 18.7). WHO-defined anemia was present in 19% of patients among both women and men. After adjustment for differences in baseline characteristics, patients with admission anemia had an adjusted OR for all-cause death at 1-month of 1.90 (95% CI, 1.05 to 3.43) and at 1-year of 1.72 (95% CI, 1.00 to 2.93) and for the combined end-point of disability, nursing facility care or death of 2.09 (95% CI, 1.13 to 3.84) and 1.83 (95% CI, 1.02 to 3.27) respectively. The relationship between hemoglobin quartiles and all-cause death revealed a non-linear association with increased risk at extremes of both low and high concentrations. In logistic regression models developed to estimate the linear and quadratic relation between hemoglobin and outcomes of interest, each unit increment in hemoglobin squared was associated with increased adjusted odds of all-cause death [at 1-month 1.06 (1.01 to 1.12; p = 0.03); at 1-year 1.09 (1.04 to 1.15; p < 0.01)], confirming that extremes of both low and high levels of hemoglobin were associated with increased mortality.</p> <p>Conclusions</p> <p>WHO-defined anemia was common in both men and women among patients with acute stroke and predicted poor outcome. Moreover, the association between admission hemoglobin and mortality was not linear; risk for death increased at both extremes of hemoglobin.</p

    Search for the standard model Higgs boson at LEP

    Get PDF

    Preparation of Group I Introns for Biochemical Studies and Crystallization Assays by Native Affinity Purification

    Get PDF
    The study of functional RNAs of various sizes and structures requires efficient methods for their synthesis and purification. Here, 23 group I intron variants ranging in length from 246 to 341 nucleotides—some containing exons—were subjected to a native purification technique previously applied only to shorter RNAs (<160 nucleotides). For the RNAs containing both exons, we adjusted the original purification protocol to allow for purification of radiolabeled molecules. The resulting RNAs were used in folding assays on native gel electrophoresis and in self-splicing assays. The intron-only RNAs were subjected to the regular native purification scheme, assayed for folding and employed in crystallization screens. All RNAs that contained a 3′ overhang of one nucleotide were efficiently cleaved off from the support and were at least 90% pure after the non-denaturing purification. A representative subset of these RNAs was shown to be folded and self-splicing after purification. Additionally, crystals were grown for a 286 nucleotide long variant of the Clostridium botulinum intron. These results demonstrate the suitability of the native affinity purification method for the preparation of group I introns. We hope these findings will stimulate a broader application of this strategy to the preparation of other large RNA molecules

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter

    Compressed representation of a partially defined integer function over multiple arguments

    Get PDF
    In OLAP (OnLine Analitical Processing) data are analysed in an n-dimensional cube. The cube may be represented as a partially defined function over n arguments. Considering that often the function is not defined everywhere, we ask: is there a known way of representing the function or the points in which it is defined, in a more compact manner than the trivial one

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    CMS Data Processing Workflows during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Search for new physics in the multijet and missing transverse momentum final state in proton-proton collisions at √s=8 Tev

    Get PDF
    Peer reviewe

    Study of double parton scattering using W+2-jet events in proton-proton collisions at √s=7 TeV

    Get PDF
    Peer reviewe

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe
    • …
    corecore