1,847 research outputs found

    H^+ -> W^+ l_i^- l_j^+$ decay in the two Higgs doublet model

    Full text link
    We study the lepton flavor violating H^+ -> W^+ l_i^- l_j^+ and the lepton flavor conserving $H^+ -> W^+ l_i^- l_i^+ (l_i=\tau, l_j=\mu) decays in the general 2HDM, so called model III. We estimate the decay width \Gamma for LFV (LFC) at the order of the magnitude of (10^{-11}-10^{-5}) GeV ((10^{-9}-10^{-4}) GeV), for 200 GeV\leq m_{H^\pm}\leq 400 GeV, and the intermediate values of the coupling \bar{\xi}^{E}_{N,\tau \mu}\sim 5 GeV (\bar{\xi}^{E}_{N,\tau \tau}\sim 30 GeV). We observe that the experimental result of the process under consideration can give comprehensive information about the physics beyond the standard model and the existing free parameters.Comment: 8 pages, 7 Figure

    Design of a precision compactor for use in guided bone regeneration in the area of oral surgery

    Get PDF
    During the processes of guided bone regeneration in the maxillary bones, which aim to recover or preserve support tissue for the placement of implants on which dental prostheses are retained, the use of various particulate graft biomaterials from different sources (animal or synthetic) is standardized. At present, the pressure of compaction of this material in the recipient bone is manual, dependent on the clinician, although there is some scientific evidence on the effects of different compressive forces on angiogenesis and prognosis of the regeneration of the grafted areas. The aim of the present study is to design, calibrate and verify in vitro a compaction instrument for clinical use, which allows a controlled and precise compaction pressure of the particulate graft biomaterial and standardize the procedure. The designed instrument is a precision compactor of adequate size for proper intra and extraoral clinical manageability and manufactured in a sterilizable material by autoclaving. The range of compression that allows (0 -1, 82 Newton), is within the forces that are commonly applied in surgery and that have been determined by a specific test on 8 oral surgeons. Instrument calibration has been performed by an independent accredited company. The testing of the instrument was carried out by an in vitro test where the biomaterial was compacted at different forces (0, 80 and 1, 82 Newton) and was observed by a computerized micro-tomography that when increasing the compression force, decreased the space between particles provided for the migration and proliferation of new blood vessels and cells. Durante los procedimientos de regeneración ósea guiada en los huesos maxilares, que tienen como objetivo recuperar o preservar tejido de soporte para la colocación de implantes sobre los que se retienen las prótesis dentales, está estandarizado el uso de diversos biomateriales de injerto particulado de diferente procedencia (animal o sintético). En la actualidad la presión de compactación de dicho material en el hueso receptor es manual, clínico dependiente, pese a que existe cierta evidencia científica sobre los efectos de las diferentes fuerzas de compresión en la angiogénesis y pronóstico de la regeneración de las zonas injertadas. El objetivo del presente estudio es el de diseñar, calibrar y comprobar in vitro un instrumento de compactación para uso clínico, que permita una presión de compactación controlada y precisa del biomaterial de injerto particulado y estandarizar el procedimiento. El instrumento diseñado es un compactador de precisión de tamaño adecuado para una correcta manejabilidad clínica intra y extraoral y fabricado en un material esterilizable por autoclavado. El rango de compresión que permite (0 – 1, 82 Newton), está dentro de las fuerzas que se aplican comúnmente en cirugía y que se han determinado mediante una prueba específica sobre 8 cirujanos orales. La calibración del instrumento se ha realizado por una empresa acreditada independiente. La comprobación del instrumento se ha realizado mediante un ensayo in vitro donde se compactó el biomaterial a diferentes fuerzas (0, 80 y 1, 82 Newton) y se observó mediante micro-tomografía computerizada que al aumentar la fuerza de compresión disminuía el espacio entre partículas provisto para la migración y proliferación de los nuevos vasos sanguíneos y células

    280 one-opposition near-Earth asteroids recovered by the EURONEAR with the <i>Isaac Newton</i> Telescope

    Get PDF
    Context. One-opposition near-Earth asteroids (NEAs) are growing in number, and they must be recovered to prevent loss and mismatch risk, and to improve their orbits, as they are likely to be too faint for detection in shallow surveys at future apparitions. Aims. We aimed to recover more than half of the one-opposition NEAs recommended for observations by the Minor Planet Center (MPC) using the Isaac Newton Telescope (INT) in soft-override mode and some fractions of available D-nights. During about 130 h in total between 2013 and 2016, we targeted 368 NEAs, among which 56 potentially hazardous asteroids (PHAs), observing 437 INT Wide Field Camera (WFC) fields and recovering 280 NEAs (76% of all targets). Methods. Engaging a core team of about ten students and amateurs, we used the THELI, Astrometrica, and the Find_Orb software to identify all moving objects using the blink and track-and-stack method for the faintest targets and plotting the positional uncertainty ellipse from NEODyS. Results. Most targets and recovered objects had apparent magnitudes centered around V ~ 22.8 mag, with some becoming as faint as V ~ 24 mag. One hundred and three objects (representing 28% of all targets) were recovered by EURONEAR alone by Aug. 2017. Orbital arcs were prolonged typically from a few weeks to a few years; our oldest recoveries reach 16 years. The O−C residuals for our 1854 NEA astrometric positions show that most measurements cluster closely around the origin. In addition to the recovered NEAs, 22 000 positions of about 3500 known minor planets and another 10 000 observations of about 1500 unknown objects (mostly main-belt objects) were promptly reported to the MPC by our team. Four new NEAs were discovered serendipitously in the analyzed fields and were promptly secured with the INT and other telescopes, while two more NEAs were lost due to extremely fast motion and lack of rapid follow-up time. They increase the counting to nine NEAs discovered by the EURONEAR in 2014 and 2015. Conclusions. Targeted projects to recover one-opposition NEAs are efficient in override access, especially using at least two-meter class and preferably larger field telescopes located in good sites, which appear even more efficient than the existing surveys

    Search for Neutral Higgs Bosons in e+e- Collisions at sqrt(s) ~189GeV

    Full text link
    A search for neutral Higgs bosons has been performed with the OPAL detector at LEP, using approximately 170 pb-1 of e+e- collision data collected at sqrt(s)~189GeV. Searches have been performed for the Standard Model (SM) process e+e- to H0Z0 and the MSSM processes e+e- to H0Z0, A0h0. The searches are sensitive to the b b-bar and tau antitau decay modes of the Higgs bosons, and also to the MSSM decay mode h0 to A0A0. OPAL search results at lower centre-of-mass energies have been incorporated in the limits we set, which are valid at the 95% confidence level. For the SM Higgs boson, we obtain a lower mass bound of 91.0 GeV. In the MSSM, our limits are mh>74.8GeV and mA>76.5GeV, assuming tan(beta)>1, that the mixing of the scalar top quarks is either zero or maximal, and that the soft SUSY-breaking masses are 1 TeV. For the case of zero scalar top mixing, we exclude values of tan(beta) between 0.72 and 2.19.Comment: 38 pages, 15 figures, submitted Euro. Phys. J.

    Observation of Pulsed Gamma-rays Above 25 GeV from the Crab Pulsar with MAGIC

    Get PDF
    One fundamental question about pulsars concerns the mechanism of their pulsed electromagnetic emission. Measuring the high-end region of a pulsar's spectrum would shed light on this question. By developing a new electronic trigger, we lowered the threshold of the Major Atmospheric gamma-ray Imaging Cherenkov (MAGIC) telescope to 25 GeV. In this configuration, we detected pulsed gamma-rays from the Crab pulsar that were greater than 25 GeV, revealing a relatively high cutoff energy in the phase-averaged spectrum. This indicates that the emission occurs far out in the magnetosphere, hence excluding the polar-cap scenario as a possible explanation of our measurement. The high cutoff energy also challenges the slot-gap scenario.Comment: Slight modification of the analysis: Fitting a more general function to the combined data set of COMPTEL, EGRET and MAGIC. Final result and conclusion is unchange

    Height and timing of growth spurt during puberty in young people living with vertically acquired HIV in Europe and Thailand.

    Get PDF
    OBJECTIVE: The aim of this study was to describe growth during puberty in young people with vertically acquired HIV. DESIGN: Pooled data from 12 paediatric HIV cohorts in Europe and Thailand. METHODS: One thousand and ninety-four children initiating a nonnucleoside reverse transcriptase inhibitor or boosted protease inhibitor based regimen aged 1-10 years were included. Super Imposition by Translation And Rotation (SITAR) models described growth from age 8 years using three parameters (average height, timing and shape of the growth spurt), dependent on age and height-for-age z-score (HAZ) (WHO references) at antiretroviral therapy (ART) initiation. Multivariate regression explored characteristics associated with these three parameters. RESULTS: At ART initiation, median age and HAZ was 6.4 [interquartile range (IQR): 2.8, 9.0] years and -1.2 (IQR: -2.3 to -0.2), respectively. Median follow-up was 9.1 (IQR: 6.9, 11.4) years. In girls, older age and lower HAZ at ART initiation were independently associated with a growth spurt which occurred 0.41 (95% confidence interval 0.20-0.62) years later in children starting ART age 6 to 10 years compared with 1 to 2 years and 1.50 (1.21-1.78) years later in those starting with HAZ less than -3 compared with HAZ at least -1. Later growth spurts in girls resulted in continued height growth into later adolescence. In boys starting ART with HAZ less than -1, growth spurts were later in children starting ART in the oldest age group, but for HAZ at least -1, there was no association with age. Girls and boys who initiated ART with HAZ at least -1 maintained a similar height to the WHO reference mean. CONCLUSION: Stunting at ART initiation was associated with later growth spurts in girls. Children with HAZ at least -1 at ART initiation grew in height at the level expected in HIV negative children of a comparable age

    Simultaneous multi-frequency observation of the unknown redshift blazar PG 1553+113 in March-April 2008

    Get PDF
    The blazar PG 1553+113 is a well known TeV gamma-ray emitter. In this paper, we determine its spectral energy distribution using simultaneous multi-frequency data in order to study its emission processes. An extensive campaign was carried out between March and April 2008, where optical, X-ray, high-energy (HE) gamma-ray, and very-high-energy (VHE) gamma-ray data were obtained with the KVA, Abastumani, REM, RossiXTE/ASM, AGILE and MAGIC telescopes, respectively. This is the first simultaneous broad-band (i.e., HE+VHE) gamma-ray observation, though AGILE did not detect the source. We combine data to derive source's spectral energy distribution and interpret its double peaked shape within the framework of a synchrotron self compton modelComment: 5 pages, 2 figures, publishe

    Standalone vertex nding in the ATLAS muon spectrometer

    Get PDF
    A dedicated reconstruction algorithm to find decay vertices in the ATLAS muon spectrometer is presented. The algorithm searches the region just upstream of or inside the muon spectrometer volume for multi-particle vertices that originate from the decay of particles with long decay paths. The performance of the algorithm is evaluated using both a sample of simulated Higgs boson events, in which the Higgs boson decays to long-lived neutral particles that in turn decay to bbar b final states, and pp collision data at √s = 7 TeV collected with the ATLAS detector at the LHC during 2011
    • …
    corecore