187 research outputs found
Bonding of the Inner Tracker Silicon Microstrip Modules
Microbonding of the CMS Tracker Inner Barrel (TIB) and Tracker Inner Disks (TID) modules was shared among six different Italian Institutes. The organization devised and the infrastructure deployed to handle this task is illustrated. Microbonding specifications and procedures for the different types of TIB and TID modules are given. The tooling specially designed and developed for these types of modules is described. Experience of production is presented. Attained production rates are given. An analysis of the microbonding quality achieved is presented, based on bond strengths measured in sample bond pull tests as well as on rates of bonding failures. Italian Bonding Centers routinely performed well above minimum specifications and a very low global introduced failure rate, at the strip level, of only 0.015 \% is observed
Self-perceived normality in defecation habits
Background: Available information on normal bowel habits was mainly gathered by means of telephone interviews or mailed questionnaires. Aims: We undertook a prospective study to evaluate the defecatory habits in subjects perceiving themselves as normal concerning this function. Subjects and Methods: A questionnaire (4-week diary with "yes-no" daily answers to six questions concerning bowel habits) was distributed to 204 subjects perceiving their defecation behaviour as normal. Results: The completed questionnaire was returned by 140 subjects. No significant differences were found between sexes or age groups for any variable, even though straining at stool and feeling of incomplete and/or difficult evacuation showed a trend to increase with age. No subject had less than three bowel movements per week or more than three per day. The percentage of symptoms linked to an abnormal defecatory behaviour was well below 10%. Fifty-five percent of subjects reported at least one parameter of abnormal functioning; the most frequent was straining at stool and the rarer was the manual manoeuvres to help defecation. Conclusions: In normal subjects the prevalence of symptoms considered in Rome II criteria as part of an abnormal defecatory behaviour (in more than 25% of defecations) is well below 10%, manual manoeuvres are almost never used to help defecation, and the frequency of defecations is at least three per week. © 2005 Editrice Gastroenterologica Italiana S.r.l
Performance studies of the Belle II Silicon Vertex Detector with data taken at the DESY test beam in April 2016
Belle II is a multipurpose detector currently under construction which will be operated at the next generation B-factory SuberKEKB in Japan. Its main devices for the vertex reconstruction are the Silicon Vertex Detector (SVD) and the Pixel Detector (PXD). In April 2016 a sector of the Belle II SVD and PXD have been tested in a beam of high energetic electrons at the test beam facility at DESY Hamburg (Germany). We report here the results for the hit efficiency estimation and the measurement of the resolution for the Belle II silicon vertex etector. We find that the hit efficiencies are on average above 99.5% and that the measured resolution is within the expectations
Performance studies of the Belle II Silicon Vertex Detector with data taken at the DESY test beam in April 2016
Belle II is a multipurpose detector currently under construction which will be operated at the next generation B-factory SuberKEKB in Japan. Its main devices for the vertex reconstruction are the Silicon Vertex Detector (SVD) and the Pixel Detector (PXD). In April 2016 a sector of the Belle II SVD and PXD have been tested in a beam of high energetic electrons at the test beam facility at DESY Hamburg (Germany). We report here the results for the hit efficiency estimation and the measurement of the resolution for the Belle II silicon vertex etector. We find that the hit efficiencies are on average above 99.5% and that the measured resolution is within the expectations
The Belle II SVD detector
The Silicon Vertex Detector (SVD) is one of the main detectors in the Belle II experiment at KEK, Japan. In combination with a pixel detector, the SVD determines precise decay vertex and low-momentum track reconstruction. The SVD ladders are being developed at several institutes. For the development of the tracking algorithm as well as the performance estimation of the ladders, beam tests for the ladders were performed. We report an overview of the SVD development, its performance measured in the beam test, and the prospect of its assembly and commissioning until installation
Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors
The Belle-II VerteX Detector (VXD) has been designed to improve the performances with respect to Belle and to cope with an unprecedented luminosity of View the MathML source8
71035cm 122s 121 achievable by the SuperKEKB. Special care is needed to monitor both the radiation dose accumulated throughout the life of the experiment and the instantaneous radiation rate, in order to be able to promptly react to sudden spikes for the purpose of protecting the detectors. A radiation monitoring and beam abort system based on single-crystal diamond sensors is now under an active development for the VXD. The sensors will be placed in several key positions in the vicinity of the interaction region. The severe space limitations require a challenging remote readout of the sensors
Belle II silicon vertex detector (SVD)
The Belle II experiment at the SuperKEKB collider in Japan will operate at an unprecedented luminosity of 8
71035 cm 122s 121, about 40 times larger than its predecessor, Belle. Its vertex detector is composed of a two-layer DEPFET pixel detector (PXD) and a four layer double-sided silicon microstrip detector (SVD). To achieve a precise decay-vertex position determination and excellent low-momentum tracking under a harsh background condition and high trigger rate of 10 kHz, the SVD employs several innovative techniques. In order to minimize the parasitic capacitance in the signal path, 1748 APV25 ASIC chips, which read out signal from 224 k strip channels, are directly mounted on the modules with the novel Origami concept. The analog signal from APV25 are digitized by a flash ADC system, and sent to the central DAQ as well as to online tracking system based on SVD hits to provide region of interests to the PXD for reducing the latter\u2019s data size to achieve the required bandwidth and data storage space. Furthermore, the state-of-the-art dual phase CO2 cooling solution has been chosen for a combined thermal management of the PXD and SVD system. In this proceedings, we present key design principles, module construction and integration status of the Belle II SVD
Belle II Vertex Detector Performance
The Belle II experiment at the SuperKEKB accelerator (KEK, Tsukuba, Japan) collected its first e+e− collision data in the spring 2019. The aim of accumulating a 50 times larger data sample than Belle at KEKB, a first generation B-Factory, presents substantial challenges to both the collider and the detector, requiring not only state-of-the-art hardware, but also modern software algorithms for tracking and alignment.
The broad physics program requires excellent performance of the vertex detector, which is composed of two layers of DEPFET pixels and four layers of double sided-strip sensors. In this contribution, an overview of the vertex detector of Belle II and our methods to ensure its optimal performance, are described, and the first results and experiences from the first physics run are presented
- …