1,928 research outputs found

    Insight from an Italian Delphi Consensus on EVAR feasibility outside the instruction for use: the SAFE EVAR Study

    Get PDF
    Background: The SAfety and FEasibility of standard EVAR outside the instruction for use (SAFE-EVAR) Study was designed to define the attitude of Italian vascular surgeons towards the use of standard endovascular repair (EVAR) for infrarenal abdominal aortic aneurysm (AAA) outside the instruction for use (IFU) through a Delphi consensus endorsed by the Italian Society of Vascular and Endovascular Surgery (Società Italiana di Chirurgia Vascolare ed Endovascolare - SICVE). Methods: A questionnaire consisting of 26 statements was developed, validated by an 18-member Advisory Board, and then sent to 600 Italian vascular surgeons. The Delphi process was structured in three subsequent rounds which took place between April and June 2023. In the first two rounds, respondents could indicate one of the following five degrees of agreement: 1) strongly agree; 2) partially agree; 3) neither agree nor disagree; 4) partially disagree; 5) strongly disagree; while in the third round only three different choices were proposed: 1) agree; 2) neither agree nor disagree; 3) disagree. We considered the consensus reached when ≥70% of respondents agreed on one of the options. After the conclusion of each round, a report describing the percentage distribution of the answers was sent to all the participants. Results: Two-hundred-forty-four (40.6%) Italian Vascular Surgeons agreed to participate the first round of the Delphi Consensus; the second and the third rounds of the Delphi collected 230 responders (94.3% of the first-round responders). Four statements (15.4%) reached a consensus in the first rounds. Among the 22 remaining statements, one more consensus (3.8%) was achieved in the second round. Finally, seven more statements (26.9%) reached a consensus in the simplified last round. Globally, a consensus was reached for almost half of the proposed statements (46.1%). Conclusions: The relatively low consensus rate obtained in this Delphi seems to confirm the discrepancy between Guideline recommendations and daily clinical practice. The data collected could represent the source for a possible guidelines' revision and the proposal of specific Good Practice Points in all those aspects with only little evidence available

    Diaphragm ultrasound evaluation during weaning from mechanical ventilation in COVID-19 patients: a pragmatic, cross-section, multicenter study

    Get PDF
    Background Diaphragmatic dysfunction is a major factor responsible for weaning failure in patients that underwent prolonged invasive mechanical ventilation for acute severe respiratory failure from COVID-19. This study hypothesizes that ultrasound measured diaphragmatic thickening fraction (DTF) could provide corroborating information for weaning COVID-19 patients from mechanical ventilation. Methods This was an observational, pragmatic, cross-section, multicenter study in 6 Italian intensive care units. DTF was assessed in COVID-19 patients undergoing weaning from mechanical ventilation from 1st March 2020 to 30th June 2021. Primary aim was to evaluate whether DTF is a predictive factor for weaning failure. Results Fifty-seven patients were enrolled, 25 patients failed spontaneous breathing trial (44%). Median length of invasive ventilation was 14 days (IQR 7-22). Median DTF within 24 h since the start of weaning was 28% (IQR 22-39%), RASS score (- 2 vs - 2; p = 0.031); Kelly-Matthay score (2 vs 1; p = 0.002); inspiratory oxygen fraction (0.45 vs 0.40; p = 0.033). PaO2/FiO(2) ratio was lower (176 vs 241; p = 0.032) and length of intensive care stay was longer (27 vs 16.5 days; p = 0.025) in patients who failed weaning. The generalized linear regression model did not select any variables that could predict weaning failure. DTF was correlated with pH (RR 1.56 x 10(27); p = 0.002); Kelly-Matthay score (RR 353; p < 0.001); RASS (RR 2.11; p = 0.003); PaO2/FiO(2) ratio (RR 1.03; p = 0.05); SAPS2 (RR 0.71; p = 0.005); hospital and ICU length of stay (RR 1.22 and 0.79, respectively; p < 0.001 and p = 0.004). Conclusions DTF in COVID-19 patients was not predictive of weaning failure from mechanical ventilation, and larger studies are needed to evaluate it in clinical practice further. Registered: ClinicalTrial.gov (NCT05019313, 24 August 2021)

    Guidelines on the management of abdominal aortic aneurysms: updates from the Italian Society of Vascular and Endovascular Surgery (SICVE)

    Get PDF
    The objective of these Guidelines was to revise and update the previous 2016 Italian Guidelines on Abdominal Aortic Aneurysm Disease, in accordance with the National Guidelines System (SNLG), to guide every practitioner toward the most correct management pathway for this pathology. The methodology applied in this update was the GRADE-SIGN version methodology, following the instructions of the AGREE quality of reporting checklist as well. The first methodological step was the formulation of clinical questions structured according to the PICO (Population, Intervention, Comparison, Outcome) model according to which the Recommendations were issued. Then, systematic reviews of the Literature were carried out for each PICO question or for homogeneous groups of questions, followed by the selection of the articles and the assessment of the methodological quality for each of them using qualitative checklists. Finally, a Considered Judgment form was filled in for each clinical question, in which the features of the evidence as a whole are assessed to establish the transition from the level of evidence to the direction and strength of the recommendations. These guidelines outline the correct management of patients with abdominal aortic aneurysm in terms of screening and surveillance. Medical management and indication for surgery are discussed, as well as preoperative assessment regarding patients' background and surgical risk evaluation. Once the indication for surgery has been established, the options for traditional open and endovascular surgery are described and compared, focusing specifically on patients with ruptured abdominal aortic aneurysms as well. Finally, indications for early and late postoperative follow-up are explained. The most recent evidence in the Literature has been able to confirm and possibly modify the previous recommendations updating them, likewise to propose new recommendations on prospectively relevant topics

    Guidelines on the diagnosis, treatment and management of visceral and renal arteries aneurysms: a joint assessment by the Italian Societies of Vascular and Endovascular Surgery (SICVE) and Medical and Interventional Radiology (SIRM)

    Get PDF
    : The objective of these Guidelines is to provide recommendations for the classification, indication, treatment and management of patients suffering from aneurysmal pathology of the visceral and renal arteries. The methodology applied was the GRADE-SIGN version, and followed the instructions of the AGREE quality of reporting checklist. Clinical questions, structured according to the PICO (Population, Intervention, Comparator, Outcome) model, were formulated, and systematic literature reviews were carried out according to them. Selected articles were evaluated through specific methodological checklists. Considered Judgments were compiled for each clinical question in which the characteristics of the body of available evidence were evaluated in order to establish recommendations. Overall, 79 clinical practice recommendations were proposed. Indications for treatment and therapeutic options were discussed for each arterial district, as well as follow-up and medical management, in both candidate patients for conservative therapy and patients who underwent treatment. The recommendations provided by these guidelines simplify and improve decision-making processes and diagnostic-therapeutic pathways of patients with visceral and renal arteries aneurysms. Their widespread use is recommended

    Measuring physical activity with activity monitors in patients with heart failure: from literature to practice. A position paper from the Committee on Exercise Physiology and Training of the Heart Failure Association of the European Society of Cardiology

    Get PDF
    The aims of this paper were to provide an overview of available activity monitors used in research in patients with heart failure and to identify the key criteria in the selection of the most appropriate activity monitor for collecting, reporting, and analysing physical activity in heart failure research. This study was conducted in three parts. First, the literature was systematically reviewed to identify physical activity concepts and activity monitors used in heart failure research. Second, an additional scoping literature search for validation of these activity monitors was conducted. Third, the most appropriate criteria in the selection of activity monitors were identified. Nine activity monitors were evaluated in terms of size, weight, placement, costs, data storage, water resistance, outcomes and validation, and cut-off points for physical activity intensity levels were discussed. The choice of a monitor should depend on the research aims, study population and design regarding physical activity. If the aim is to motivate patients to be active or set goals, a less rigorously tested tool can be considered. On the other hand, if the aim is to measure physical activity and its changes over time or following treatment adjustment, it is important to choose a valid activity monitor with a storage and battery longevity of at least one week. The device should provide raw data and valid cut-off points should be chosen for analysing physical activity intensity levels. Other considerations in choosing an activity monitor should include data storage location and ownership and the upfront costs of the device

    Association between preoperative evaluation with lung ultrasound and outcome in frail elderly patients undergoing orthopedic surgery for hip fractures: study protocol for an Italian multicenter observational prospective study (LUSHIP)

    Get PDF
    Hip fracture is one of the most common orthopedic causes of hospital admission in frail elderly patients. Hip fracture fixation in this class of patients is considered a high-risk procedure. Preoperative physical examination, plasma natriuretic peptide levels (BNP, Pro-BNP), and cardiovascular scoring systems (ASA-PS, RCRI, NSQIP-MICA) have all been demonstrated to underestimate the risk of postoperative complications. We designed a prospective multicenter observational study to assess whether preoperative lung ultrasound examination can predict better postoperative events thanks to the additional information they provide in the form of "indirect" and "direct" cardiac and pulmonary lung ultrasound signs

    Tracker Operation and Performance at the Magnet Test and Cosmic Challenge

    Get PDF
    During summer 2006 a fraction of the CMS silicon strip tracker was operated in a comprehensive slice test called the Magnet Test and Cosmic Challenge (MTCC). At the MTCC, cosmic rays detected in the muon chambers were used to trigger the readout of all CMS sub-detectors in the general data acquisition system and in the presence of the 4 T magnetic field produced by the CMS superconducting solenoid. This document describes the operation of the Tracker hardware and software prior, during and after data taking. The performance of the detector as resulting from the MTCC data analysis is also presented

    Differential cross section measurements for the production of a W boson in association with jets in proton–proton collisions at √s = 7 TeV

    Get PDF
    Measurements are reported of differential cross sections for the production of a W boson, which decays into a muon and a neutrino, in association with jets, as a function of several variables, including the transverse momenta (pT) and pseudorapidities of the four leading jets, the scalar sum of jet transverse momenta (HT), and the difference in azimuthal angle between the directions of each jet and the muon. The data sample of pp collisions at a centre-of-mass energy of 7 TeV was collected with the CMS detector at the LHC and corresponds to an integrated luminosity of 5.0 fb[superscript −1]. The measured cross sections are compared to predictions from Monte Carlo generators, MadGraph + pythia and sherpa, and to next-to-leading-order calculations from BlackHat + sherpa. The differential cross sections are found to be in agreement with the predictions, apart from the pT distributions of the leading jets at high pT values, the distributions of the HT at high-HT and low jet multiplicity, and the distribution of the difference in azimuthal angle between the leading jet and the muon at low values.United States. Dept. of EnergyNational Science Foundation (U.S.)Alfred P. Sloan Foundatio

    Penilaian Kinerja Keuangan Koperasi di Kabupaten Pelalawan

    Full text link
    This paper describe development and financial performance of cooperative in District Pelalawan among 2007 - 2008. Studies on primary and secondary cooperative in 12 sub-districts. Method in this stady use performance measuring of productivity, efficiency, growth, liquidity, and solvability of cooperative. Productivity of cooperative in Pelalawan was highly but efficiency still low. Profit and income were highly, even liquidity of cooperative very high, and solvability was good
    corecore