187 research outputs found

    Paternal and maternal long-term psychological outcomes after uterine artery embolization for severe post-partum hemorrhage.

    Get PDF
    This study intend to compare the long-term psychological impact (depression, post-traumatic stress disorder) on both partners between patients that underwent uterine artery embolization (UAE) for post-partum hemorrhage (PPH) and uneventful deliveries. Women who experienced severe PPH treated by UAE in our institution between 2003 and 2013 were identified in our obstetrical database. These cases were matched to controls with uneventful deliveries. Matching criteria were maternal age, parity, ethnicity, year of delivery, birthweight, gestational age and mode of delivery. Patients and their partners completed validated questionnaires measuring post-traumatic stress (TSQ), as well as depression symptoms (MINI). A total of 63 cases of PPH and 189 matched controls (1:3) participated in a study exploring gynecological and obstetrical outcomes. With a mean of 8 years post-index delivery, patients after PPH showed increased risk of depression (p = 0.015) and post-traumatic stress disorder (22.2% versus 4.8%, p < 0.005) compared to controls. PPH remains strongly associated with post-traumatic stress disorder, even after adjustment for depression (adjusted odds ratio 5.1; 95% confidence intervals 1.5-17.5). Similarly, partners of patients with PPH showed a propensity to depression (p = 0.029) and post-traumatic stress disorder (11.5% versus 1.5%, p = 0.019). In conclusion, both women and their partners are at increased risk of long-term psychological adverse outcomes after PPH. Couples may benefit from psychological support

    Gynecological, reproductive and sexual outcomes after uterine artery embolization for post-partum haemorrage.

    Get PDF
    In this case control study, long-term gynecological, reproductive and sexual outcomes after uterine artery embolization (UAE) for postpartum hemorrhage (PPH) were evaluated. The study was performed in a single referral hospital for PPH in Lausanne from 2003 to 2013. Each woman whose delivery was complicated by PPH and treated by UAE was included, and compared to a control group of women whose delivery was uncomplicated. Cases were matched by maternal age, parity, ethnicity, year and mode of delivery, birth weight and gestational age in a 1-3 ratio. A total of 77 patients treated by UAE for PPH were identified in our obstetrical database. Among them, 63 were included and compared to 189 matched patients (no PPH). The mean interval time between UAE and this study was 8.1 years. Time to menstrual cycle recovery after delivery (3.9 vs 5.6 months, p = 0.66), spotting (7.9% vs 7.2%, p = 0.49), dysmenorrhea (25.4% vs 22.2%, p = 0.60) and amenorrhea (14.3% vs 12.2%, p = 0.66) were similar between the two groups. There was no difference in the FSFI score between the groups (23.2 Âą 0.6 vs 23.8 Âą 0.4; p = 0.41). However, the interval time to subsequent pregnancy was longer for patients after UAE than the control group (35 vs 18 months, p = 0.002). In case of pregnancy desire, the success rate was lower after UAE compared to controls (55% vs 93.5%, p < 0.001). The rate of PPH was higher in those with previous PPH (6.6% vs 36.4%, p = 0.010). Patients treated by UAE for PPH did not report higher rates of gynecological symptoms or sexual dysfunction compared to patients with uneventful deliveries. The inter-pregnancy interval was increased and the success rate was reduced. In subsequent pregnancies, a higher rate of PPH was observed in those that underwent UAE

    Minimal spontaneously broken hidden sector and its impact on Higgs boson physics at the Large Hadron Collider

    Get PDF
    We have studied a hidden sector of the SM with spontaneous symmetry breaking that opens many different scenarios for Higgs physics. We have shown that this hidden sector can affect the SM Higgs detection. In some speci c regimes it is still possible to detect the Higgs; in other scenarios the hidden sector would completely eclipse it

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Omalizumab efficacy in cases of chronic spontaneous urticaria is not explained by the inhibition of sera activity in effector cells

    Get PDF
    Omalizumab (OmAb) is a humanized anti-IgE antibody approved for the treatment of chronic spontaneous urticaria (CSU). OmAb's mechanism of action is known to include actions on free IgE and on pre-bound IgE. However, OmAb is equally and rapidly effective against autoimmune and non-autoimmune urticaria where IgE involvement is not clear, suggesting the involvement of additional mechanisms of action. In this study, we sought to investigate the ability of OmAb to inhibit mast cell and basophil degranulation induced by sera from CSU patients. For this purpose, we performed a comparison between the in vitro incubation of sera from CSU patients treated with OmAb and the in vivo administration of OmAb in a clinical trial. We found that OmAb added in vitro to sera from CSU patients did not modify the ability of the sera to induce cell degranulation. Similarly, the sera from patients treated with OmAb in the context of the clinical trial who had a good clinical outcome maintained the capacity to activate mast cells and basophils. Thus, we conclude that the beneficial activity of OmAb does not correlate with the ability of patient sera to induce cell degranulation

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Evaluation-as-a-service for the computational sciences: overview and outlook

    Get PDF
    Evaluation in empirical computer science is essential to show progress and assess technologies developed. Several research domains such as information retrieval have long relied on systematic evaluation to measure progress: here, the Cranfield paradigm of creating shared test collections, defining search tasks, and collecting ground truth for these tasks has persisted up until now. In recent years, however, several new challenges have emerged that do not fit this paradigm very well: extremely large data sets, confidential data sets as found in the medical domain, and rapidly changing data sets as often encountered in industry. Crowdsourcing has also changed the way in which industry approaches problem-solving with companies now organizing challenges and handing out monetary awards to incentivize people to work on their challenges, particularly in the field of machine learning. This article is based on discussions at a workshop on Evaluation-as-a-Service (EaaS). EaaS is the paradigm of not providing data sets to participants and have them work on the data locally, but keeping the data central and allowing access via Application Programming Interfaces (API), Virtual Machines (VM), or other possibilities to ship executables. The objectives of this article are to summarize and compare the current approaches and consolidate the experiences of these approaches to outline the next steps of EaaS, particularly toward sustainable research infrastructures. The article summarizes several existing approaches to EaaS and analyzes their usage scenarios and also the advantages and disadvantages. The many factors influencing EaaS are summarized, and the environment in terms of motivations for the various stakeholders, from funding agencies to challenge organizers, researchers and participants, to industry interested in supplying real-world problems for which they require solutions. EaaS solves many problems of the current research environment, where data sets are often not accessible to many researchers. Executables of published tools are equally often not available making the reproducibility of results impossible. EaaS, however, creates reusable/citable data sets as well as available executables. Many challenges remain, but such a framework for research can also foster more collaboration between researchers, potentially increasing the speed of obtaining research results

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe
    • …
    corecore