656 research outputs found

    Photoresponsive and Ultraviolet to Visible-Light Range Photocatalytic Properties of ZnO:Sb Nanowires

    Get PDF
    100學年度研究獎補助論文[[abstract]]Zinc oxide (ZnO) doped antimony (Sb) nanowires have been synthesized for improving ultraviolet sensing and photocatalytic properties. Upon illumination by UV light (365nm , 2.33mWcm−2 ), the photoelectric current of the ZnO:Sb nanowires exhibited a rapid photoresponse as compared to that of the ZnO nanowires. A highest ratio of photocurrent to dark current of around 48.8-fold was achieved in the as-synthesized ZnO:Sb nanowires. A UV-visible spectrophotometer was used to investigate the absorbance spectrum of the ZnO:Sb nanowires, which exhibited a high absorbance ratio with redshift effect in contrast to that of the ZnO nanowires. Visible-light photocatalysis and UV photoresponsive properties of the ZnO:Sb nanowires are superior to those of the ZnO nanowires.[[notice]]補正完畢[[incitationindex]]SCI[[booktype]]電子

    Observational Constraints on the Modified Gravity Model (MOG) Proposed by Moffat: Using the Magellanic System

    Full text link
    A simple model for the dynamics of the Magellanic Stream (MS), in the framework of modified gravity models is investigated. We assume that the galaxy is made up of baryonic matter out of context of dark matter scenario. The model we used here is named Modified Gravity (MOG) proposed by Moffat (2005). In order to examine the compatibility of the overall properties of the MS under the MOG theory, the observational radial velocity profile of the MS is compared with the numerical results using the χ2\chi^2 fit method. In order to obtain the best model parameters, a maximum likelihood analysis is performed. We also compare the results of this model with the Cold Dark Matter (CDM) halo model and the other alternative gravity model that proposed by Bekenstein (2004), so called TeVeS. We show that by selecting the appropriate values for the free parameters, the MOG theory seems to be plausible to explain the dynamics of the MS as well as the CDM and the TeVeS models.Comment: 14 pages, 3 Figures, accepted in Int. J. Theor. Phy

    FGF receptor genes and breast cancer susceptibility: results from the Breast Cancer Association Consortium

    Get PDF
    Background:Breast cancer is one of the most common malignancies in women. Genome-wide association studies have identified FGFR2 as a breast cancer susceptibility gene. Common variation in other fibroblast growth factor (FGF) receptors might also modify risk. We tested this hypothesis by studying genotyped single-nucleotide polymorphisms (SNPs) and imputed SNPs in FGFR1, FGFR3, FGFR4 and FGFRL1 in the Breast Cancer Association Consortium. Methods:Data were combined from 49 studies, including 53 835 cases and 50 156 controls, of which 89 050 (46 450 cases and 42 600 controls) were of European ancestry, 12 893 (6269 cases and 6624 controls) of Asian and 2048 (1116 cases and 932 controls) of African ancestry. Associations with risk of breast cancer, overall and by disease sub-type, were assessed using unconditional logistic regression. Results:Little evidence of association with breast cancer risk was observed for SNPs in the FGF receptor genes. The strongest evidence in European women was for rs743682 in FGFR3; the estimated per-allele odds ratio was 1.05 (95 confidence interval=1.02-1.09, P=0.0020), which is substantially lower than that observed for SNPs in FGFR2. Conclusion:Our results suggest that common variants in the other FGF receptors are not associated with risk of breast cancer to the degree observed for FGFR2. © 2014 Cancer Research UK

    Time-integrated luminosity recorded by the BABAR detector at the PEP-II e+e- collider

    Get PDF
    This article is the Preprint version of the final published artcile which can be accessed at the link below.We describe a measurement of the time-integrated luminosity of the data collected by the BABAR experiment at the PEP-II asymmetric-energy e+e- collider at the ϒ(4S), ϒ(3S), and ϒ(2S) resonances and in a continuum region below each resonance. We measure the time-integrated luminosity by counting e+e-→e+e- and (for the ϒ(4S) only) e+e-→μ+μ- candidate events, allowing additional photons in the final state. We use data-corrected simulation to determine the cross-sections and reconstruction efficiencies for these processes, as well as the major backgrounds. Due to the large cross-sections of e+e-→e+e- and e+e-→μ+μ-, the statistical uncertainties of the measurement are substantially smaller than the systematic uncertainties. The dominant systematic uncertainties are due to observed differences between data and simulation, as well as uncertainties on the cross-sections. For data collected on the ϒ(3S) and ϒ(2S) resonances, an additional uncertainty arises due to ϒ→e+e-X background. For data collected off the ϒ resonances, we estimate an additional uncertainty due to time dependent efficiency variations, which can affect the short off-resonance runs. The relative uncertainties on the luminosities of the on-resonance (off-resonance) samples are 0.43% (0.43%) for the ϒ(4S), 0.58% (0.72%) for the ϒ(3S), and 0.68% (0.88%) for the ϒ(2S).This work is supported by the US Department of Energy and National Science Foundation, the Natural Sciences and Engineering Research Council (Canada), the Commissariat à l’Energie Atomique and Institut National de Physique Nucléaire et de Physiquedes Particules (France), the Bundesministerium für Bildung und Forschung and Deutsche Forschungsgemeinschaft (Germany), the Istituto Nazionale di Fisica Nucleare (Italy), the Foundation for Fundamental Research on Matter (The Netherlands), the Research Council of Norway, the Ministry of Education and Science of the Russian Federation, Ministerio de Ciencia e Innovación (Spain), and the Science and Technology Facilities Council (United Kingdom). Individuals have received support from the Marie-Curie IEF program (European Union) and the A.P. Sloan Foundation (USA)

    Numerical evaluation of spray position for improved nasal drug delivery

    Get PDF
    Topical intra-nasal sprays are amongst the most commonly prescribed therapeutic options for sinonasal diseases in humans. However, inconsistency and ambiguity in instructions show a lack of definitive knowledge on best spray use techniques. In this study, we have identified a new usage strategy for nasal sprays available over-the-counter, that registers an average 8-fold improvement in topical delivery of drugs at diseased sites, when compared to prevalent spray techniques. The protocol involves re-orienting the spray axis to harness inertial motion of particulates and has been developed using computational fluid dynamics simulations of respiratory airflow and droplet transport in medical imaging-based digital models. Simulated dose in representative models is validated through in vitro spray measurements in 3D-printed anatomic replicas using the gamma scintigraphy technique. This work breaks new ground in proposing an alternative user-friendly strategy that can significantly enhance topical delivery inside human nose. While these findings can eventually translate into personalized spray usage instructions and hence merit a change in nasal standard-of-care, this study also demonstrates how relatively simple engineering analysis tools can revolutionize everyday healthcare. Finally, with respiratory mucosa as the initial coronavirus infection site, our findings are relevant to intra-nasal vaccines that are in-development, to mitigate the COVID-19 pandemic

    A steady-state genetic algorithm with resampling for noisy inventory control

    Get PDF
    Noisy fitness functions occur in many practical applications of evolutionary computation. A standard technique for solving these problems is fitness resampling but this may be inefficient or need a large population, and combined with elitism it may overvalue chromosomes or reduce genetic diversity. We describe a simple new resampling technique called Greedy Average Sampling for steady-state genetic algorithms such as GENITOR. It requires an extra runtime parameter to be tuned, but does not need a large population or assumptions on noise distributions. In experiments on a well-known Inventory Control problem it performed a large number of samples on the best chromosomes yet only a small number on average, and was more effective than four other tested technique

    Detection, evaluation, and management of preoperative anaemia in the elective orthopaedic surgical patient: NATA guidelines

    Get PDF
    Previously undiagnosed anaemia is common in elective orthopaedic surgical patients and is associated with increased likelihood of blood transfusion and increased perioperative morbidity and mortality. A standardized approach for the detection, evaluation, and management of anaemia in this setting has been identified as an unmet medical need. A multidisciplinary panel of physicians was convened by the Network for Advancement of Transfusion Alternatives (NATA) with the aim of developing practice guidelines for the detection, evaluation, and management of preoperative anaemia in elective orthopaedic surgery. A systematic literature review and critical evaluation of the evidence was performed, and recommendations were formulated according to the method proposed by the Grades of Recommendation Assessment, Development and Evaluation (GRADE) Working Group. We recommend that elective orthopaedic surgical patients have a haemoglobin (Hb) level determination 28 days before the scheduled surgical procedure if possible (Grade 1C). We suggest that the patient's target Hb before elective surgery be within the normal range, according to the World Health Organization criteria (Grade 2C). We recommend further laboratory testing to evaluate anaemia for nutritional deficiencies, chronic renal insufficiency, and/or chronic inflammatory disease (Grade 1C). We recommend that nutritional deficiencies be treated (Grade 1C). We suggest that erythropoiesis-stimulating agents be used for anaemic patients in whom nutritional deficiencies have been ruled out, corrected, or both (Grade 2A). Anaemia should be viewed as a serious and treatable medical condition, rather than simply an abnormal laboratory value. Implementation of anaemia management in the elective orthopaedic surgery setting will improve patient outcomes

    Constraints on anomalous QGC's in e+ee^{+}e^{-} interactions from 183 to 209 GeV

    Get PDF
    The acoplanar photon pairs produced in the reaction e(+) e(-) - → vvyy are analysed in the 700 pb(-1) of data collected by the ALEPH detector at centre-of-mass energies between 183 and 209 GeV. No deviation from the Standard Model predictions is seen in any of the distributions examined. The resulting 95% C.L. limits set on anomalous QGCs, a(0)(Z), a(c)(Z), a(0)(W) and a(c)(W), are -0.012 lt a(0)(Z)/Lambda(2) lt +0.019 GeV-2, -0.041 lt a(c)(Z)/Lambda(2) lt +0.044 GeV-2, -0.060 lt a(0)(W)/Lambda(2) lt +0.055 GeV-2, -0.099 lt a(c)(W)/Lambda(2) lt +0.093 GeV-2, where Lambda is the energy scale of the new physics responsible for the anomalous couplings
    corecore