48 research outputs found

    Very long-term efficacy and safety of paclitaxel-eluting balloon after a bare-metal stent for the treatment of ST-elevation myocardial infarction: 8-year results of a randomized clinical trial (PEBSI study)

    Get PDF
    Drug-eluting stents; Drug-coated balloons; Myocardial infarctionStents alliberadors de fàrmacs; Globus recoberts de fàrmacs; Infart de miocardiStents liberadores de fármacos; Globos recubiertos de fármacos; Infarto de miocardioBackground: Drug-eluting stents (DES) are considered the therapy of choice in ST-segment elevation myocardial infarction (STEMI); however, a low persistent rate of revascularizations and stent thrombosis exist over the time. We have previously shown that a paclitaxel (PTX)-drug-coated balloon (DCB) after a bare-metal stent (BMS) implantation (DCB-combined strategy) yields superior angiographic and clinical results compared to BMS in the short term. However, the long-term safety and efficacy of this approach remain uncertain. Methods: An 8-year clinical follow-up was conducted on patients enrolled in the randomized PEBSI-1 trial (NCT01839890). The original trial included patients who suffered a STEMI, patients were randomly assigned to receive a DCB-combined strategy or BMS only and the primary endpoint was in-stent late luminal loss (LLL) at 9-month follow-up. After the completion of this study, death, myocardial re-infarction, ischemia-driven repeated revascularizations included target lesion revascularization (TLR) and target vessel revascularization (TVR), and stent thrombosis, were assessed by yearly contact by a clinical visit, telephone or by electronic records. These outcomes were adhered to ARC-2 criteria. Results: The rate of incomplete follow-up was very low, with only 3 out of 111 patients (2.7%) in the DCB-combined strategy group and 1 out of 112 patients (0.9%) in the BMS group. At 8 years there were a lower rate of TVR [3.7% vs. 14.3%; hazard ratio (HR): 0.243; 95% confidence interval (CI): 0.081–0.727; P=0.006], and a trend towards lower TLR (2.8% vs. 8.9%; HR: 0.300; 95% CI: 0.083–1.090; P=0.052) in the DCB-combined strategy group. No statistical difference between the DCB-combined strategy and BMS groups were found for all causes of death, deaths from cardiovascular disease, reinfarctions or stent thrombosis. Notably in the DCB-combined strategy group, no episode of stent thrombosis occurred after the first year. Similarly, there were no cardiovascular deaths, TVR and TLR in the DCB-combined strategy group after 5 years. In contrast, during the period from year 5 to 8, the BMS group experienced an additional cardiovascular death, as well as one case of TVR, one case of TLR, and one case of stent thrombosis. Conclusions: In STEMI patients, the DCB-combined strategy maintains its safety and clinical efficacy over time. Our rates of TVR, TLR, and very late stent thrombosis (VLST) at very long-term are the lowest ever found in a STEMI trial. Further studies are warranted to assess the potential superiority of this novel strategy as compared with new-generation DES to prevent very late events in these patients. Trial Registration: ClinicalTrials.gov; identifier: NCT01839890.This investigation has received the support of the Spanish Clinical Research Network (SCReN), financed by the ISCIII-Subdirección General de Evaluación y Fomento de la Investigación, under the project PT13/0002/0005 (Plan Estatal de I+D+I 2013-2016) and co-funded by the European Regional Development Fund (FEDER). An unrestricted research grant was received from Biotronik

    Denervación renal en el tratamiento de la hipertensión arterial. Posicionamiento conjunto de la SEH-LELHA y la ACI-SEC

    Full text link
    Hypertension is the most prevalent cardiovascular risk factor. Despite pharmacological treatment, a high percentage of patients do not achieve an adequate blood pressure control. Renal sympathetic denervation is a minimally invasive intervention for the management of hypertension involving the interruption of the renal artery sympathetic nervous system using a catheter-based approach. The early studies showed promising results, but the controversial results coming from the SYMPLICITY HTN-3 trial sent this technique into oblivion. Over the last 3 years, new clinical trials have appeared including new devices used in different populations, which definitively proves the effectiveness of renal sympathetic denervation. This joint position statement from the Spanish Society of Hypertension-Spanish League for Combating High Blood Pressure (SEH-LELHA), and the Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC) reviews the evidence available on the efficacy and safety profile of renal sympathetic denervation for the management of hypertension. Based on the results of clinical trials, recommendations have been established on what patients may be eligible for renal sympathetic denervation and under what circumstances

    A Randomized Comparison of Drug-Eluting Balloon Versus Everolimus-Eluting Stent in Patients With Bare-Metal Stent–In-Stent Restenosis The RIBS V Clinical Trial (Restenosis Intra-stent of Bare Metal Stents: Paclitaxel-eluting Balloon vs. Everolimus-eluting Stent)

    Get PDF
    ObjectivesThis study sought to compare the efficacy of drug-eluting balloons (DEB) with that of everolimus-eluting stents (EES) in patients with bare-metal stents (BMS) in-stent restenosis (ISR).BackgroundTreatment of patients with ISR remains a challenge.MethodsThis was a prospective, multicenter, randomized trial comparing DEB with EES in patients with bare-metal stents (BMS) in-stent restenosis (ISR). The primary endpoint was the minimal lumen diameter at 9 months' follow-up.ResultsA total of 189 patients with BMS-ISR from 25 Spanish sites were included (95 were allocated to DEB and 94 to EES). Procedural success was achieved in all patients. At late angiography (median 249 days; 92% of eligible patients), patients in the EES arm had a significantly larger minimal lumen diameter (2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm, p < 0.001; absolute mean difference: 0.35 mm; 95% confidence interval [CI]: 0.16 to 0.53) and a lower percent of diameter stenosis (13 ± 17% vs. 25 ± 20%, p < 0.001). However, late loss (0.04 ± 0.5 mm vs. 0.14 ± 0.5 mm, p = 0.14) and binary restenosis rate (4.7% vs. 9.5%, p = 0.22) were very low and similar in both groups. Clinical follow-up (median 365 days) was obtained in all (100%) patients. Occurrences of the combined clinical outcome measure (cardiac death, myocardial infarction, and target vessel revascularization; 6% vs. 8%; hazard ratio [HR]: 0.76; 95% CI: 0.26 to 2.18, p = 0.6) and the need for target vessel revascularization (2% vs. 6%; HR: 0.32: 95% CI: 0.07 to 1.59, p = 0.17) were similar in the 2 groups.ConclusionsIn patients with BMS-ISR, both DEB and EES provided excellent clinical results with a very low rate of clinical and angiographic recurrences. However, compared with DEB, EES provide superior late angiographic findings. (Restenosis Intra-stent of Bare Metal Stents: Paclitaxel-eluting Balloon vs. Everolimus-eluting Stent [RIBS V]; NCT01239953

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Measurement of the charge asymmetry in top-quark pair production in the lepton-plus-jets final state in pp collision data at s=8TeV\sqrt{s}=8\,\mathrm TeV{} with the ATLAS detector

    Get PDF

    ATLAS Run 1 searches for direct pair production of third-generation squarks at the Large Hadron Collider

    Get PDF

    Measurements of top-quark pair differential cross-sections in the eμe\mu channel in pppp collisions at s=13\sqrt{s} = 13 TeV using the ATLAS detector

    Get PDF

    Search for single production of vector-like quarks decaying into Wb in pp collisions at s=8\sqrt{s} = 8 TeV with the ATLAS detector

    Get PDF

    Measurement of the W boson polarisation in ttˉt\bar{t} events from pp collisions at s\sqrt{s} = 8 TeV in the lepton + jets channel with ATLAS

    Get PDF

    Measurement of the bbb\overline{b} dijet cross section in pp collisions at s=7\sqrt{s} = 7 TeV with the ATLAS detector

    Get PDF
    corecore