114 research outputs found

    Building an LO source at 1036 GHz for a receiver

    Get PDF
    The goal of the UMass work on this grant was to build an LO source at 1036 GHz for a receiver which was to be built at JPL. The 1 THz source will consist of a high power Gunn oscillator at 86 GHz followed by a cascaded pair of planar diode doublers and finally a whisker contacted tripler. All multipliers will use single mode waveguide mounts. This use of single mode waveguide even for the final mount is a departure from the original plan, and reflects the progress that has been made in fabricating small structures. The advantages to the use of waveguide over a quasi-optical approach are that the complete system is much more compact, and much easier to use

    Spectra of Nearby Galaxies Measured with a New Very Broadband Receiver

    Get PDF
    Three-millimeter-wavelength spectra of a number of nearby galaxies have been obtained at the Five College Radio Astronomy Observatory (FCRAO) using a new, very broadband receiver. This instrument, which we call the Redshift Search Receiver, has an instantaneous bandwidth of 36 GHz and operates from 74 to 110.5 GHz. The receiver has been built at UMass/FCRAO to be part of the initial instrumentation for the Large Millimeter Telescope (LMT) and is intended primarily for determination of the redshift of distant, dust-obscured galaxies. It is being tested on the FCRAO 14m by measuring the 3mm spectra of a number of nearby galaxies. There are interesting differences in the chemistry of these galaxies.Comment: published in the Proceedings of the International Astronomical Union (2008), 4. Vol 251, pp 251-256 Cambridge University Pres

    The Redshift Search Receiver 3 mm Wavelength Spectra of 10 Galaxies

    Get PDF
    The 3 mm wavelength spectra of 10 galaxies have been obtained at the Five College Radio Astronomy Observatory using a new, very broadband receiver and spectrometer, called the Redshift Search Receiver (RSR). The RSR has an instantaneous bandwidth of 37 GHz covering frequencies from 74 to 111 GHz, and has a spectral resolution of 31 MHz (~100 km/s). During tests of the RSR on the FCRAO 14 m telescope the complete 3 mm spectra of the central regions of NGC 253, Maffei 2, NGC1068, IC 342, M82, NGC 3079, NGC 3690, NGC 4258, Arp 220 and NGC 6240 were obtained. Within the wavelength band covered by the RSR, 20 spectral lines from 14 different atomic and molecular species were detected. Based on simultaneous fits to the spectrum of each galaxy, a number of key molecular line ratios are derived. A simple model which assumes the emission arises from an ensemble of Milky Way-like Giant Nolecular Cloud cores can adequately fit the observed line ratios using molecular abundances based on Galactic molecular cloud cores. Variations seen in some line ratios, such as 13CO/HCN and HCO+/HCN, can be explained if the mean density of the molecular gas varies from galaxy to galaxy. However, NGC 3690, NGC 4258 and NGC 6240 show very large HCO+/HCN ratios and require significant abundance enhancement of HCO+ over HCN, possible due to the proximity to active galactic nucleus activity. Finally, the mass of dense molecular gas is estimated and we infer that 25-85 % of the total molecular gas in the central regions of these galaxies must have densities greater than 10^4 cm^-3.Comment: accepted for publication in A.

    A high resolution line survey of IRC+10216 with Herschel. First results: Detection of warm silicon dicarbide SiC2

    Get PDF
    We present the first results of a high-spectral-resolution survey of the carbon-rich evolved star IRC+10216 that was carried out with the HIFI spectrometer onboard Herschel. This survey covers all HIFI bands, with a spectral range from 488 to 1901GHz. In this letter we focus on the band-1b spectrum, in a spectral range 554.5-636.5GHz, where we identified 130 spectral features with intensities above 0.03 K and a signal-to-noise ratio >5. Detected lines arise from HCN, SiO, SiS, CS, CO, metal-bearing species and, surprisingly, silicon dicarbide (SiC2). We identified 55 SiC2 transitions involving energy levels between 300 and 900 K. By analysing these rotational lines, we conclude that SiC2 is produced in the inner dust formation zone, with an abundance of ~2x10^-7 relative to molecular hydrogen. These SiC2 lines have been observed for the first time in space and have been used to derive an SiC2 rotational temperature of ~204 K and a source-averaged column density of ~6.4x10^15 cm^-2. Furthermore, the high quality of the HIFI data set was used to improve the spectroscopic rotational constants of SiC2.Comment: A&A HIFI Special Issue, 201

    Radiometer Calibration Using Colocated GPS Radio Occultation Measurements

    Get PDF
    We present a new high-fidelity method of calibrating a cross-track scanning microwave radiometer using Global Positioning System (GPS) radio occultation (GPSRO) measurements. The radiometer and GPSRO receiver periodically observe the same volume of atmosphere near the Earth's limb, and these overlapping measurements are used to calibrate the radiometer. Performance analyses show that absolute calibration accuracy better than 0.25 K is achievable for temperature sounding channels in the 50-60-GHz band for a total-power radiometer using a weakly coupled noise diode for frequent calibration and proximal GPSRO measurements for infrequent (approximately daily) calibration. The method requires GPSRO penetration depth only down to the stratosphere, thus permitting the use of a relatively small GPS antenna. Furthermore, only coarse spacecraft angular knowledge (approximately one degree rms) is required for the technique, as more precise angular knowledge can be retrieved directly from the combined radiometer and GPSRO data, assuming that the radiometer angular sampling is uniform. These features make the technique particularly well suited for implementation on a low-cost CubeSat hosting both radiometer and GPSRO receiver systems on the same spacecraft. We describe a validation platform for this calibration method, the Microwave Radiometer Technology Acceleration (MiRaTA) CubeSat, currently in development for the National Aeronautics and Space Administration (NASA) Earth Science Technology Office. MiRaTA will fly a multiband radiometer and the Compact TEC/Atmosphere GPS Sensor in 2015.United States. Dept. of Defense. Assistant Secretary of Defense for Research & Engineering (United States. Air Force Contract FA8721-05-C-0002

    Executive Summary of the Second International Guidelines for the Diagnosis and Management of Pediatric Acute Respiratory Distress Syndrome (PALICC-2)

    Get PDF
    OBJECTIVES: We sought to update our 2015 work in the Second Pediatric Acute Lung Injury Consensus Conference (PALICC-2) guidelines for the diagnosis and management of pediatric acute respiratory distress syndrome (PARDS), considering new evidence and topic areas that were not previously addressed. DESIGN: International consensus conference series involving 52 multidisciplinary international content experts in PARDS and four methodology experts from 15 countries, using consensus conference methodology, and implementation science. SETTING: Not applicable. PATIENTS: Patients with or at risk for PARDS. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Eleven subgroups conducted systematic or scoping reviews addressing 11 topic areas: 1) definition, incidence, and epidemiology; 2) pathobiology, severity, and risk stratification; 3) ventilatory support; 4) pulmonary-specific ancillary treatment; 5) nonpulmonary treatment; 6) monitoring; 7) noninvasive respiratory support; 8) extracorporeal support; 9) morbidity and long-term outcomes; 10) clinical informatics and data science; and 11) resource-limited settings. The search included MEDLINE, EMBASE, and CINAHL Complete (EBSCOhost) and was updated in March 2022. Grading of Recommendations, Assessment, Development, and Evaluation methodology was used to summarize evidence and develop the recommendations, which were discussed and voted on by all PALICC-2 experts. There were 146 recommendations and statements, including: 34 recommendations for clinical practice; 112 consensus-based statements with 18 on PARDS definition, 55 on good practice, seven on policy, and 32 on research. All recommendations and statements had agreement greater than 80%. CONCLUSIONS: PALICC-2 recommendations and consensus-based statements should facilitate the implementation and adherence to the best clinical practice in patients with PARDS. These results will also inform the development of future programs of research that are crucially needed to provide stronger evidence to guide the pediatric critical care teams managing these patients.</p

    Discordant identification of pediatric severe sepsis by research and clinical definitions in the SPROUT international point prevalence study

    Get PDF
    Introduction: Consensus criteria for pediatric severe sepsis have standardized enrollment for research studies. However, the extent to which critically ill children identified by consensus criteria reflect physician diagnosis of severe sepsis, which underlies external validity for pediatric sepsis research, is not known. We sought to determine the agreement between physician diagnosis and consensus criteria to identify pediatric patients with severe sepsis across a network of international pediatric intensive care units (PICUs). Methods: We conducted a point prevalence study involving 128 PICUs in 26 countries across 6 continents. Over the course of 5 study days, 6925 PICU patients &lt;18 years of age were screened, and 706 with severe sepsis defined either by physician diagnosis or on the basis of 2005 International Pediatric Sepsis Consensus Conference consensus criteria were enrolled. The primary endpoint was agreement of pediatric severe sepsis between physician diagnosis and consensus criteria as measured using Cohen's ?. Secondary endpoints included characteristics and clinical outcomes for patients identified using physician diagnosis versus consensus criteria. Results: Of the 706 patients, 301 (42.6 %) met both definitions. The inter-rater agreement (? ± SE) between physician diagnosis and consensus criteria was 0.57 ± 0.02. Of the 438 patients with a physician's diagnosis of severe sepsis, only 69 % (301 of 438) would have been eligible to participate in a clinical trial of pediatric severe sepsis that enrolled patients based on consensus criteria. Patients with physician-diagnosed severe sepsis who did not meet consensus criteria were younger and had lower severity of illness and lower PICU mortality than those meeting consensus criteria or both definitions. After controlling for age, severity of illness, number of comorbid conditions, and treatment in developed versus resource-limited regions, patients identified with severe sepsis by physician diagnosis alone or by consensus criteria alone did not have PICU mortality significantly different from that of patients identified by both physician diagnosis and consensus criteria. Conclusions: Physician diagnosis of pediatric severe sepsis achieved only moderate agreement with consensus criteria, with physicians diagnosing severe sepsis more broadly. Consequently, the results of a research study based on consensus criteria may have limited generalizability to nearly one-third of PICU patients diagnosed with severe sepsis

    Measurement of the e^(+)e^(-)→ bb(macron) cross section between √s = 10.54 and 11.20 GeV

    Get PDF
    We report e^(+)e^(-)→ bb(macron) cross section measurements by the BABAR experiment performed during an energy scan in the range of 10.54 to 11.20 GeV at the SLAC PEP-II e^(+)e^(-) collider. A total relative error of about 5% is reached in more than 300 center-of-mass energy steps, separated by about 5 MeV. These measurements can be used to derive precise information on the parameters of the Y (10860) and Y (11020) resonances. In particular we show that their widths may be smaller than previously measured

    The Physics of the B Factories

    Get PDF
    This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C
    corecore