931 research outputs found
Carbon nanotube four-terminal devices for pressure sensing applications
Carbon nanotubes (CNTs) are of high interest for sensing applications,owing to their superior mechanical strength, high Youngâs modulus and low density. In this work, we report on a facile approach for the fabrication of carbon nanotube devices using a four terminal configuration. Oriented carbon nanotube films were pulled out from a CNT forest wafer and then twisted into a yarn. Both the CNT film and yarn were arranged on elastomer membranes/diaphragms which were arranged on a laser cut acrylic frame to form pressure sensors. The sensors were calibrated using a precisely controlled pressure system, showing a large change of the output voltage of approximately 50 mV at a constant supply current of 100 ÎźA and under a low applied pressure of 15 mbar. The results indicate the high potential of using CNT films and yarns for pressure sensing applications
Response to imatinib rechallenge in a patient with a recurrent gastrointestinal stromal tumor after adjuvant therapy: a case report
<p>Abstract</p> <p>Introduction</p> <p>Adjuvant imatinib improves recurrence-free survival of patients following resection of primary KIT-positive gastrointestinal stromal tumors. However, it is unknown whether patients who previously received adjuvant imatinib therapy will respond to imatinib rechallenge as treatment for recurrent disease. Here we present the first report documenting the benefits of imatinib rechallenge in a patient previously exposed to imatinib during adjuvant treatment.</p> <p>Case presentation</p> <p>A 51-year-old Asian woman with a wedge-resected primary gastric gastrointestinal stromal tumor at high risk of relapse underwent two years of adjuvant treatment with imatinib. Only 10 months after the completion of adjuvant imatinib treatment, a computed tomography scan revealed gastrointestinal stromal tumor recurrence in this patient, with multiple peritoneal nodules in the upper abdomen being detected. Our patient was rechallenged with imatinib 400 mg/day and had a partial response after one month of treatment. Imatinib rechallenge was well tolerated by our patient; the only adverse events she experienced were grade 1 edema, anemia and fatigue. Our patient maintained a partial response two years and six months after the imatinib rechallenge. However, computed tomography scans three months later showed that our patient had disease progression.</p> <p>Conclusions</p> <p>This case report demonstrates that a patient with a gastrointestinal stromal tumor who had previously received adjuvant imatinib therapy responded to imatinib rechallenge as treatment for her recurrent disease. These results indicate that imatinib sensitivity can be maintained in a patient with previous exposure to adjuvant imatinib therapy.</p
The Mitochondrial Ca(2+) Uniporter: Structure, Function, and Pharmacology.
Mitochondrial Ca(2+) uptake is crucial for an array of cellular functions while an imbalance can elicit cell death. In this chapter, we briefly reviewed the various modes of mitochondrial Ca(2+) uptake and our current understanding of mitochondrial Ca(2+) homeostasis in regards to cell physiology and pathophysiology. Further, this chapter focuses on the molecular identities, intracellular regulators as well as the pharmacology of mitochondrial Ca(2+) uniporter complex
Vagal Stimulation Modulates Inflammation through a Ghrelin Mediated Mechanism in Traumatic Brain Injury
Traumatic brain injury (TBI) releases a cascade of inflammatory cytokines. Vagal nerve stimulation (VNS) and ghrelin have known anti-inflammatory effects; furthermore, ghrelin release is stimulated by acetylcholine. We hypothesized VNS decreases post-TBI inflammation through a ghrelin-mediated mechanism. TBI was created in five groups of mice: sham, TBI, TBI/ghrelin, TBI/VNS, and TBI/VNS/ghrelin receptor antagonist (GRa). Serum and tissue ghrelin, and serum TNF-Îą were measured. Ghrelin increased following VNS 2Â h post-TBI compared to sham or TBI. At 6Â h, TBI and TBI/VNS/GRa had increased TNF-Îą compared to sham while TBI/VNS and TBI/ghrelin had TNF-Îą level comparable to sham. The highest ghrelin was measured in stomach where TBI decreased ghrelin in contrast to an increase by VNS. In conclusion, VNS increased serum ghrelin and decreased TNF-Îą following TBI. This was abrogated with GRa. Our data suggests that ghrelin plays an important role in the anti-inflammatory effects of VNS following TBI
Severe community-acquired adenovirus pneumonia in an immunocompetent 44-year-old woman: a case report and review of the literature
<p>Abstract</p> <p>Introduction</p> <p>This case report describes a rare condition: community-acquired adenovirus pneumonia in an immunocompetent adult. The diagnosis was achieved by using a multiplex real-time reverse transcriptase polymerase chain reaction (RT-PCR) assay and highlights the usefulness of these novel molecular diagnostic techniques in patients hospitalized with acute respiratory illness. We also performed a literature search for previously published cases and present a summary of the clinical, laboratory and radiological features of this condition.</p> <p>Case presentation</p> <p>A 44-year-old immunocompetent Caucasian woman was admitted to our hospital with an acute febrile respiratory illness associated with a rash. Her blood tests were non-specifically abnormal, and tests for bacterial pathogens were negative. Her condition rapidly deteriorated while she was in our hospital and required mechanical ventilation and inotropic support. A multiplex real-time RT-PCR assay performed on respiratory specimens to detect respiratory viruses was negative for influenza but positive for adenovirus DNA. The patient recovered on supportive treatment, and antibiotics were stopped after 5 days.</p> <p>Conclusions</p> <p>Community-acquired adenovirus pneumonia in immunocompetent adult civilians presents as a non-specific acute febrile respiratory illness followed by the abrupt onset of respiratory failure, often requiring mechanical ventilation. Its laboratory and radiological features are typical of viral infections but also are non-specific. Novel multiplex real-time RT-PCR testing for respiratory viruses enabled us to rapidly make the diagnosis in this case. The new technology could be used more widely in patients with acute respiratory illness and has potential utility for rationalization of the use of antibiotics and improving infection control measures.</p
Precise measurement of the W-boson mass with the CDF II detector
We have measured the W-boson mass MW using data corresponding to 2.2/fb of
integrated luminosity collected in proton-antiproton collisions at 1.96 TeV
with the CDF II detector at the Fermilab Tevatron collider. Samples consisting
of 470126 W->enu candidates and 624708 W->munu candidates yield the measurement
MW = 80387 +- 12 (stat) +- 15 (syst) = 80387 +- 19 MeV. This is the most
precise measurement of the W-boson mass to date and significantly exceeds the
precision of all previous measurements combined
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
X-ray emission from the Sombrero galaxy: discrete sources
We present a study of discrete X-ray sources in and around the
bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival
Chandra observations with a total exposure of ~200 ks. With a detection limit
of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30
kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler
et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS
observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray
binaries (LMXBs). We quantify the differential luminosity functions (LFs) for
both the detected GC and field LMXBs, whose power-low indices (~1.1 for the
GC-LF and ~1.6 for field-LF) are consistent with previous studies for
elliptical galaxies. With precise sky positions of the GCs without a detected
X-ray source, we further quantify, through a fluctuation analysis, the GC LF at
fainter luminosities down to 1E35 erg/s. The derived index rules out a
faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent
findings in several elliptical galaxies and the bulge of M31. On the other
hand, the 2-6 keV unresolved emission places a tight constraint on the field
LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101
sources in the halo of Sombrero. The presence of these sources cannot be
interpreted as galactic LMXBs whose spatial distribution empirically follows
the starlight. Their number is also higher than the expected number of cosmic
AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray
surveys. We suggest that either the cosmic X-ray background is unusually high
in the direction of Sombrero, or a distinct population of X-ray sources is
present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
- âŚ