249 research outputs found

    Regional comparison of absolute gravimeters SIM.M.G-K1 key comparison

    Get PDF
    Twelve absolute gravimeters were compared during the regional Key Comparison SIM.M.G-K1 of absolute gravimeters. The four gravimeters were from different NMIs and DIs. The comparison was linked to the CCM.G-K2 through EURAMET.M.G-K2 via the DI gravimeter FG5X-216. Overall, the results and uncertainties indicate an excellent agreement among the gravimeters, with a standard deviation of the gravimeters' DoEs better than 1.3 μGal. In the case of the official solution, all the gravimeters are in equivalence well within the declared uncertainties. == Main text To reach the main text of this paper, click on Final Report [http://www.bipm.org/utils/common/pdf/final_reports/M/G-K1/SIM.M.G-K1.pdf] . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ [http://kcdb.bipm.org/] . The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA)

    Surgical site infection after caesarean section. Space for post-discharge surveillance improvements and reliable comparisons

    Get PDF
    Surgical site infections (SSI) after caesarean section (CS) represent a substantial health system concern. Surveying SSI has been associated with a reduction in SSI incidence. We report the findings of three (2008, 2011 and 2013) regional active SSI surveillances after CS in community hospital of the Latium region determining the incidence of SSI. Each CS was surveyed for SSI occurrence by trained staff up to 30 post-operative days, and association of SSI with relevant characteristics was assessed using binomial logistic regression. A total of 3,685 CS were included in the study. A complete 30 day post-operation follow-up was achieved in over 94% of procedures. Overall 145 SSI were observed (3.9% cumulative incidence) of which 131 (90.3%) were superficial and 14 (9.7%) complex (deep or organ/space) SSI; overall 129 SSI (of which 89.9% superficial) were diagnosed post-discharge. Only higher NNIS score was significantly associated with SSI occurrence in the regression analysis. Our work provides the first regional data on CS-associated SSI incidence, highlighting the need for a post-discharge surveillance which should assure 30 days post-operation to not miss data on complex SSI, as well as being less labour intensive

    Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter

    Get PDF
    This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPEnsuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered

    Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up

    Get PDF
    Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated

    The Brazilian Program for Biodiversity Research (PPBio) Information System.

    Get PDF
    The database of the Brazilian Program for Biodiversity Research (PPBio; GIVD ID SA-BR-001) includes data on the environment and biological groups such as plants. It is organized by site, which is usually a grid with 10 to 72 uniformly-distributed plots, and has already surveyed 1,638 relevés across different Brazilian ecosystems. The sampling design is based on the RAPELD system to allow integration of data from diverse taxa and ecosystem processes. RAPELD is a spatially-explicit sampling scheme to monitor biodiversity in long-term ecological research sites and during rapid appraisals of biodiversity that has attracted support from many management agencies, which are using it as their long-term monitoring system. Vegetation surveys include measurements of cover, biomass and number of individuals from woody and herbaceous vascular plants, along with environmental data. We have recently migrated to a metadata catalog and data repository which allows searching for specific groups across all sites. All RAPELD data have been collected since 2001, though the site also allows data from other long-term plots to be archived as associated projects

    Fine roots stimulate nutrient release during early stages of leaf litter decomposition in a Central Amazon rainforest

    Get PDF
    Purpose Large parts of the Amazon rainforest grow on weathered soils depleted in phosphorus and rock-derived cations. We tested the hypothesis that in this ecosystem, fine roots stimulate decomposition and nutrient release from leaf litter biochemically by releasing enzymes, and by exuding labile carbon stimulating microbial decomposers. Methods We monitored leaf litter decomposition in a Central Amazon tropical rainforest, where fine roots were either present or excluded, over 188 days and added labile carbon substrates (glucose and citric acid) in a fully factorial design. We tracked litter mass loss, remaining carbon, nitrogen, phosphorus and cation concentrations, extracellular enzyme activity and microbial carbon and nutrient concentrations. Results Fine root presence did not affect litter mass loss but significantly increased the loss of phosphorus and cations from leaf litter. In the presence of fine roots, acid phosphatase activity was 43.2% higher, while neither microbial stoichiometry, nor extracellular enzyme activities targeting carbon- and nitrogen-containing compounds changed. Glucose additions increased phosphorus loss from litter when fine roots were present, and enhanced phosphatase activity in root exclusions. Citric acid additions reduced litter mass loss, microbial biomass nitrogen and phosphorus, regardless of fine root presence or exclusion. Conclusions We conclude that plant roots release significant amounts of acid phosphatases into the litter layer and mobilize phosphorus without affecting litter mass loss. Our results further indicate that added labile carbon inputs (i.e. glucose) can stimulate acid phosphatase production by microbial decomposers, highlighting the potential importance of plant-microbial feedbacks in tropical forest ecosystems

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Search for the standard model Higgs boson decaying into two photons in pp collisions at sqrt(s)=7 TeV

    Get PDF
    A search for a Higgs boson decaying into two photons is described. The analysis is performed using a dataset recorded by the CMS experiment at the LHC from pp collisions at a centre-of-mass energy of 7 TeV, which corresponds to an integrated luminosity of 4.8 inverse femtobarns. Limits are set on the cross section of the standard model Higgs boson decaying to two photons. The expected exclusion limit at 95% confidence level is between 1.4 and 2.4 times the standard model cross section in the mass range between 110 and 150 GeV. The analysis of the data excludes, at 95% confidence level, the standard model Higgs boson decaying into two photons in the mass range 128 to 132 GeV. The largest excess of events above the expected standard model background is observed for a Higgs boson mass hypothesis of 124 GeV with a local significance of 3.1 sigma. The global significance of observing an excess with a local significance greater than 3.1 sigma anywhere in the search range 110-150 GeV is estimated to be 1.8 sigma. More data are required to ascertain the origin of this excess.Comment: Submitted to Physics Letters
    corecore