61 research outputs found

    Failure of Hem-o-lok clips

    Get PDF
    Hem-o-lok clips are commonly used for renal artery ligation in laparoscopic renal surgery. However, failure of the renal artery ligation clips is potentially fatal. A 61-year-old man underwent hand-assisted laparoscopic nephroureterectomy using a retroperitoneal approach for left ureteral carcinoma. One hour postoperatively, he was diagnosed with hemorrhagic shock. An immediate laparotomy revealed two closed, undamaged Hem-o-lok clips around the left renal artery. Pulsatile bleeding was observed, and the renal artery was immediately ligated with non-absorbable thread. We determined that the failure of the Hem-o-lok clips on the renal artery was caused by the lack of space between the two Hem-o-lok clips and the distal renal artery cuff beyond the distal clip. To prevent a potentially fatal failure of the renal artery ligation clips, one should maintain a sufficient space between the Hem-o-lok clips and an adequate distal renal artery cuff beyond the distal clip

    Compartment Syndrome after Prostatectomy

    Get PDF
    Robot-assisted laparoscopic prostatectomy (RALP) for prostate cancer was introduced in 2000 and rapidly gained popularity. The Da Vinci Surgical System® can ensure improved local control of cancer and fewer perioperative complications. However, RALP is performed in the steep-Trendelenburg position (a combination of lithotomy and head-down tilt position / Lloyd-Davies position) to obtain a good surgical view, and as a result, well leg compartment syndrome (WLCS) can become a serious complication of RALP. Here, we report a case of WLCS after RALP. A 75-year-old man underwent surgery for prostate cancer and immediately complained of pain and numbness after surgery. The pressure of the four leg compartments increased. Ultimately, we diagnosed the patient with WLCS in his right leg, and an emergency fasciotomy was performed. He completely recovered with no permanent disability and was discharged one month after rehabilitation. Although WLCS after RALP is a rare and severe complication, the patient recovered completely with early diagnosis and intervention. Measuring the compartment pressure is useful when the patient is drowsy immediately after recovery from anesthesia. Preventing WLCS requires identifying this condition as a potential complication of RALP and all urologic surgeries performed in the lithotomy position

    Dynamics of dissolved and bubbled methane in Lake Youngrang and HwaJlnPO, Korea

    Get PDF
    Article信州大学山地水環境教育研究センター研究報告 6: 69-72(2010)departmental bulletin pape

    Primary leiomyoma of the bladder

    Get PDF
    The case presented is of a 47-year-old patient with an extravesical pedunculated bladder leiomyoma, which was difficult to distinguish from a retroperitoneal tumor. Preoperatively, it was suspected to be a retroperitoneal tumor and a laparotomy with tumor resection was performed. lntraoperatively, the bladder and tumor were connected by a cord-like tissue. A retrospective review of preoperative images revealed that cord-like tissue, identified intraoperatively, was also present. Bladder leiomyomas can grow as extravesical pedunculated tumors. Therefore, when the continuity between the bladder and tumor is only a cord-like object, the finding of continuity is useful to diagnose with bladder leiomyoma

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Measurement of jet fragmentation in Pb+Pb and pppp collisions at sNN=2.76\sqrt{{s_\mathrm{NN}}} = 2.76 TeV with the ATLAS detector at the LHC

    Get PDF
    corecore