613 research outputs found

    D-Branes on the Conifold and N=1 Gauge/Gravity Dualities

    Full text link
    We review extensions of the AdS/CFT correspondence to gauge/ gravity dualities with N=1 supersymmetry. In particular, we describe the gauge/gravity dualities that emerge from placing D3-branes at the apex of the conifold. We consider first the conformal case, with discussions of chiral primary operators and wrapped D-branes. Next, we break the conformal symmetry by adding a stack of partially wrapped D5-branes to the system, changing the gauge group and introducing a logarithmic renormalization group flow. In the gravity dual, the effect of these wrapped D5-branes is to turn on the flux of 3-form field strengths. The associated RR 2-form potential breaks the U(1) R-symmetry to Z2MZ_{2M} and we study this phenomenon in detail. This extra flux also leads to deformation of the cone near the apex, which describes the chiral symmetry breaking and confinement in the dual gauge theory.Comment: Based on I.R.K.'s lectures at the Les Houches Summer School Session 76, ``Gravity, Gauge Theories, and Strings'', August 2001, 42 pages, v2: clarifications and references adde

    Incommensurable worldviews? Is public use of complementary and alternative medicines incompatible with support for science and conventional medicine?

    Get PDF
    Proponents of controversial Complementary and Alternative Medicines, such as homeopathy, argue that these treatments can be used with great effect in addition to, and sometimes instead of, ?conventional? medicine. In doing so, they accept the idea that the scientific approach to the evaluation of treatment does not undermine use of and support for some of the more controversial CAM treatments. For those adhering to the scientific canon, however, such efficacy claims lack the requisite evidential basis from randomised controlled trials. It is not clear, however, whether such opposition characterises the views of the general public. In this paper we use data from the 2009 Wellcome Monitor survey to investigate public use of and beliefs about the efficacy of a prominent and controversial CAM within the United Kingdom, homeopathy. We proceed by using Latent Class Analysis to assess whether it is possible to identify a sub-group of the population who are at ease in combining support for science and conventional medicine with use of CAM treatments, and belief in the efficacy of homeopathy. Our results suggest that over 40% of the British public maintain positive evaluations of both homeopathy and conventional medicine simultaneously. Explanatory analyses reveal that simultaneous support for a controversial CAM treatment and conventional medicine is, in part, explained by a lack of scientific knowledge as well as concerns about the regulation of medical research

    Detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT)

    Get PDF
    The purpose of this study was to analyze the detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG-PET/CT). Data for a total of 492 patients who had undergone both PET/CT and colonoscopy were analyzed. After the findings of PET/CT and colonoscopy were determined independently, the results were compared in each of the six colonic sites examined in all patients. The efficacy of PET/CT was determined using colonoscopic examination as the gold standard. In all, 270 colorectal lesions 5 mm or more in size, including 70 pathologically confirmed malignant lesions, were found in 172 patients by colonoscopy. The sensitivity and specificity of PET/CT for detecting any of the colorectal lesions were 36 and 98%, respectively. For detecting lesions 11 mm or larger, the sensitivity was increased to 85%, with the specificity remaining consistent (97%). Moreover, the sensitivity for tumors 21 mm or larger was 96% (48/50). Tumors with malignant or high-grade pathology were likely to be positive with PET/CT. A size of 10 mm or smaller [odds ratio (OR) 44.14, 95% confidence interval (95% CI) 11.44-221.67] and flat morphology (OR 7.78, 95% CI 1.79-36.25) were significant factors that were associated with false-negative cases on PET/CT. The sensitivity of PET/CT for detecting colorectal lesions is acceptable, showing size- and pathology-dependence, suggesting, for the most part, that clinically relevant lesions are detectable with PET/CT. However, when considering PET/CT for screening purposes caution must be exercised because there are cases of false-negative results

    The unwarped, resolved, deformed conifold: fivebranes and the baryonic branch of the Klebanov-Strassler theory

    Get PDF
    We study a gravity solution corresponding to fivebranes wrapped on the S2S^2 of the resolved conifold. By changing a parameter the solution continuously interpolates between the deformed conifold with flux and the resolved conifold with branes. Therefore, it displays a geometric transition, purely in the supergravity context. The solution is a simple example of torsional geometry and may be thought of as a non-K\"ahler analog of the conifold. By U-duality transformations we can add D3 brane charge and recover the solution in the form originally derived by Butti et al. This describes the baryonic branch of the Klebanov-Strassler theory. Far along the baryonic branch the field theory gives rise to a fuzzy two-sphere. This corresponds to the D5 branes wrapping the two-sphere of the resolved conifold in the gravity solution.Comment: 41 pages, 7 figure

    The genetic basis of DOORS syndrome: an exome-sequencing study.

    Get PDF
    Deafness, onychodystrophy, osteodystrophy, mental retardation, and seizures (DOORS) syndrome is a rare autosomal recessive disorder of unknown cause. We aimed to identify the genetic basis of this syndrome by sequencing most coding exons in affected individuals

    Effective Rheology of Bubbles Moving in a Capillary Tube

    Full text link
    We calculate the average volumetric flux versus pressure drop of bubbles moving in a single capillary tube with varying diameter, finding a square-root relation from mapping the flow equations onto that of a driven overdamped pendulum. The calculation is based on a derivation of the equation of motion of a bubble train from considering the capillary forces and the entropy production associated with the viscous flow. We also calculate the configurational probability of the positions of the bubbles.Comment: 4 pages, 1 figur

    Search for displaced vertices arising from decays of new heavy particles in 7 TeV pp collisions at ATLAS

    Get PDF
    We present the results of a search for new, heavy particles that decay at a significant distance from their production point into a final state containing charged hadrons in association with a high-momentum muon. The search is conducted in a pp-collision data sample with a center-of-mass energy of 7 TeV and an integrated luminosity of 33 pb^-1 collected in 2010 by the ATLAS detector operating at the Large Hadron Collider. Production of such particles is expected in various scenarios of physics beyond the standard model. We observe no signal and place limits on the production cross-section of supersymmetric particles in an R-parity-violating scenario as a function of the neutralino lifetime. Limits are presented for different squark and neutralino masses, enabling extension of the limits to a variety of other models.Comment: 8 pages plus author list (20 pages total), 8 figures, 1 table, final version to appear in Physics Letters

    Measurement of the polarisation of W bosons produced with large transverse momentum in pp collisions at sqrt(s) = 7 TeV with the ATLAS experiment

    Get PDF
    This paper describes an analysis of the angular distribution of W->enu and W->munu decays, using data from pp collisions at sqrt(s) = 7 TeV recorded with the ATLAS detector at the LHC in 2010, corresponding to an integrated luminosity of about 35 pb^-1. Using the decay lepton transverse momentum and the missing transverse energy, the W decay angular distribution projected onto the transverse plane is obtained and analysed in terms of helicity fractions f0, fL and fR over two ranges of W transverse momentum (ptw): 35 < ptw < 50 GeV and ptw > 50 GeV. Good agreement is found with theoretical predictions. For ptw > 50 GeV, the values of f0 and fL-fR, averaged over charge and lepton flavour, are measured to be : f0 = 0.127 +/- 0.030 +/- 0.108 and fL-fR = 0.252 +/- 0.017 +/- 0.030, where the first uncertainties are statistical, and the second include all systematic effects.Comment: 19 pages plus author list (34 pages total), 9 figures, 11 tables, revised author list, matches European Journal of Physics C versio

    Observation of a new chi_b state in radiative transitions to Upsilon(1S) and Upsilon(2S) at ATLAS

    Get PDF
    The chi_b(nP) quarkonium states are produced in proton-proton collisions at the Large Hadron Collider (LHC) at sqrt(s) = 7 TeV and recorded by the ATLAS detector. Using a data sample corresponding to an integrated luminosity of 4.4 fb^-1, these states are reconstructed through their radiative decays to Upsilon(1S,2S) with Upsilon->mu+mu-. In addition to the mass peaks corresponding to the decay modes chi_b(1P,2P)->Upsilon(1S)gamma, a new structure centered at a mass of 10.530+/-0.005 (stat.)+/-0.009 (syst.) GeV is also observed, in both the Upsilon(1S)gamma and Upsilon(2S)gamma decay modes. This is interpreted as the chi_b(3P) system.Comment: 5 pages plus author list (18 pages total), 2 figures, 1 table, corrected author list, matches final version in Physical Review Letter
    corecore