68 research outputs found

    Multi-channel pre-beamformed data acquisition system for research on advanced ultrasound imaging methods

    Get PDF
    The lack of open access to the pre-beamformed data of an ultrasound scanner has limited the research of novel imaging methods to a few privileged laboratories. To address this need, we have developed a pre-beamformed data acquisition (DAQ) system that can collect data over 128 array elements in parallel from the Ultrasonix series of research-purpose ultrasound scanners. Our DAQ system comprises three system-level blocks: 1) a connector board that interfaces with the array probe and the scanner through a probe connector port; 2) a main board that triggers DAQ and controls data transfer to a computer; and 3) four receiver boards that are each responsible for acquiring 32 channels of digitized raw data and storing them to the on-board memory. This system can acquire pre-beamformed data with 12-bit resolution when using a 40-MHz sampling rate. It houses a 16 GB RAM buffer that is sufficient to store 128 channels of pre-beamformed data for 8000 to 25 000 transmit firings, depending on imaging depth; corresponding to nearly a 2-s period in typical imaging setups. Following the acquisition, the data can be transferred through a USB 2.0 link to a computer for offline processing and analysis. To evaluate the feasibility of using the DAQ system for advanced imaging research, two proof-of-concept investigations have been conducted on beamforming and plane-wave B-flow imaging. Results show that adaptive beamforming algorithms such as the minimum variance approach can generate sharper images of a wire cross-section whose diameter is equal to the imaging wavelength (150 μm in our example). Also, planewave B-flow imaging can provide more consistent visualization of blood speckle movement given the higher temporal resolution of this imaging approach (2500 fps in our example). © 2012 IEEE.published_or_final_versio

    Physical activity as a modifiable risk factor for periodontal disease

    Get PDF
    Non-communicable diseases (NCDs), which contribute significantly to global morbidity, are largely preventable through behavioral changes. As with other NCDs, periodontitis is associated with modifiable risk factors such as smoking and stress and is linked to multiple adverse health outcomes through a shared pathway of chronic systemic inflammation. While the health benefits of physical activity have been widely promoted in public health and extensively studied for other systemic conditions, its impact on periodontal health has only recently started to gain attention. This article critically evaluates the current literature on the relationship between physical activity and periodontitis. While cross-sectional studies have shown an inverse association between physical activity levels and periodontitis risk in the general population, clinical oral health surveys of elite athletes with high levels of physical activity have nonetheless revealed poor periodontal conditions. Although causality has not been determined, physical activity could positively impact periodontitis directly, by reducing inflammatory biomarkers, and indirectly, through its modulatory effects on insulin sensitivity, obesity, bone density, stress, and other health promoting behaviors. Given the importance of risk factor control during initial periodontal therapy, understanding the role of physical activity as a potential behavioral risk modifier is paramount. The findings of this review provide an evidence-based overview of how physical activity could influence periodontitis. There is a need for longitudinal cohort studies to verify the temporality of the reported associations and exclude confounders, while interventions are needed to assess the efficacy of physical activity on periodontal treatment outcomes

    Intrusion detection routers: Design, implementation and evaluation using an experimental testbed

    Get PDF
    In this paper, we present the design, the implementation details, and the evaluation results of an intrusion detection and defense system for distributed denial-of-service (DDoS) attack. The evaluation is conducted using an experimental testbed. The system, known as intrusion detection router (IDR), is deployed on network routers to perform online detection on any DDoS attack event, and then react with defense mechanisms to mitigate the attack. The testbed is built up by a cluster of sufficient number of Linux machines to mimic a portion of the Internet. Using the testbed, we conduct real experiments to evaluate the IDR system and demonstrate that IDR is effective in protecting the network from various DDoS attacks. © 2006 IEEE.published_or_final_versio

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Studies of jet quenching using isolated-photon + jet correlations in PbPb and pp collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    Results from the first study of isolated-photon + jet correlations in relativistic heavy ion collisions are reported. The analysis uses data from PbPb collisions at a centre-of-mass energy of 2.76 TeV per nucleon pair corresponding to an integrated luminosity of 150 inverse microbarns recorded by the CMS experiment at the LHC. For events containing an isolated photon with transverse momentum pt(gamma) > 60 GeV and an associated jet with pt(Jet) > 30 GeV, the photon + jet pt imbalance is studied as a function of collision centrality and compared to pp data and PYTHIA calculations at the same collision energy. Using the pt(gamma) of the isolated photon as an estimate of the momentum of the associated parton at production, this measurement allows an unbiased characterisation of the in-medium parton energy loss. For more central PbPb collisions, a significant decrease in the ratio pt(Jet)/pt(gamma) relative to that in the PYTHIA reference is observed. Furthermore, significantly more pt(gamma) > 60 GeV photons in PbPb are observed not to have an associated pt(Jet) > 30 GeV jet, compared to the reference. However, no significant broadening of the photon + jet azimuthal correlation is observed.Comment: Submitted to Physics Letters

    Measurement of the inclusive jet cross section in pp collisions at √s = 7TeV

    Get PDF
    This is the pre-print version of the Published Article which can be accessed from the link below.The inclusive jet cross section is measured in pp collisions with a center-of-mass energy of 7 TeV at the Large Hadron Collider using the CMS experiment. The data sample corresponds to an integrated luminosity of 34  pb-1. The measurement is made for jet transverse momenta in the range 18–1100 GeV and for absolute values of rapidity less than 3. The measured cross section extends to the highest values of jet pT ever observed and, within the experimental and theoretical uncertainties, is generally in agreement with next-to-leading-order perturbative QCD predictions

    Measurement of the inclusive jet cross section in pp collisions at √s=7TeV

    Get PDF
    Abstract The inclusive jet cross section is measured in pp collisions with a center-of-mass energy of 7 TeV at the Large Hadron Collider using the CMS experiment. The data sample corresponds to an integrated luminosity of 34 pb(-1). The measurement is made for jet transverse momenta in the range 18-1100 GeV and for absolute values of rapidity less than 3. The measured cross section extends to the highest values of jet p(T) ever observed and, within the experimental and theoretical uncertainties, is generally in agreement with next-to-leading-order perturbative QCD predictions

    Discutindo a educação ambiental no cotidiano escolar: desenvolvimento de projetos na escola formação inicial e continuada de professores

    Get PDF
    A presente pesquisa buscou discutir como a Educação Ambiental (EA) vem sendo trabalhada, no Ensino Fundamental e como os docentes desta escola compreendem e vem inserindo a EA no cotidiano escolar., em uma escola estadual do município de Tangará da Serra/MT, Brasil. Para tanto, realizou-se entrevistas com os professores que fazem parte de um projeto interdisciplinar de EA na escola pesquisada. Verificou-se que o projeto da escola não vem conseguindo alcançar os objetivos propostos por: desconhecimento do mesmo, pelos professores; formação deficiente dos professores, não entendimento da EA como processo de ensino-aprendizagem, falta de recursos didáticos, planejamento inadequado das atividades. A partir dessa constatação, procurou-se debater a impossibilidade de tratar do tema fora do trabalho interdisciplinar, bem como, e principalmente, a importância de um estudo mais aprofundado de EA, vinculando teoria e prática, tanto na formação docente, como em projetos escolares, a fim de fugir do tradicional vínculo “EA e ecologia, lixo e horta”.Facultad de Humanidades y Ciencias de la Educació

    Towards integrative learning in biomedical engineering: A project course on electrocardiogram monitor design

    No full text
    This paper presents the development of a guided project course that aims to help biomedical engineering students integrate technical concepts in electric circuits, biomedical instrumentation, and human physiology. Our course involves the design of an electrocardiogram monitor from scratch, and it differs from other lab-based courses that comprise a series of individual experiments. There are three project stages in this course: 1) breadboard prototype design, 2) device fabrication using printed circuit board techniques, and 3) pilot experimentation. Each stage has its own aligned set of objectives, learning activities, and assessment exercises for students to achieve or complete. Course surveys have been conducted at the end of the first two stages to solicit ongoing feedback from students. The survey results indicate that many students have high learning interest in our course mainly because it is the first time for them to build a medical device and use it to perform experiments. Many have agreed that the course has helped to develop their critical thinking and problem solving skills, although there are concerns over its heavy workload as compared to lecture-based courses. ©2009 IEEE.link_to_subscribed_fulltex
    corecore