    Heteronuclear micro-helmholtz coil facilitates μm-range spatial and sub-Hz spectral resolution NMR of nL-volume samples on customisable microfluidic chips

    Get PDF
    We present a completely revised generation of a modular micro-NMR detector, featuring an active sample volume of ∗ 100 nL, and an improvement of 87% in probe efficiency. The detector is capable of rapidly screening different samples using exchangeable, applicationspecific, MEMS-fabricated, microfluidic sample containers. In contrast to our previous design, the sample holder chips can be simply sealed with adhesive tape, with excellent adhesion due to the smooth surfaces surrounding the fluidic ports, and so withstand pressures of ∗2.5 bar, while simultaneously enabling high spectral resolution up to 0.62 Hz for H2 O, due to its optimised geometry. We have additionally reworked the coil design and fabrication processes, replacing liquid photoresists by dry film stock, whose final thickness does not depend on accurate volume dispensing or precise levelling during curing. We further introduced mechanical alignment structures to avoid time-intensive optical alignment of the chip stacks during assembly, while we exchanged the laser-cut, PMMA spacers by diced glass spacers, which are not susceptible to melting during cutting. Doing so led to an overall simplification of the entire fabrication chain, while simultaneously increasing the yield, due to an improved uniformity of thickness of the individual layers, and in addition, due to more accurate vertical positioning of the wirebonded coils, now delimited by a post base plateau. We demonstrate the capability of the design by acquiring a1 H spectrum of ∗ \11 nmol sucrose dissolved in D2 O, where we achieved a linewidth of 1.25 Hz for the TSP reference peak. Chemical shift imaging experiments were further recorded from voxel volumes of only ∗ 1.5nL, which corresponded to amounts of just 1.5 nmol per voxel for a 1 M concentration. To extend the micro-detector to other nuclei of interest, we have implemented a trap circuit, enabling heteronuclear spectroscopy, demonstrated by two 1H/13 C 2D HSQC experiments. © 2016 Spengler et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited

    Load sensitive stable current source for complex precision pulsed electroplating

    Get PDF
    Electrodeposition is a highly versatile and well explored technology. However, it also depends strongly on the experience level of the operator. This experience includes the pretreatment of the sample, and the composition of the electrolyte settings of the plating parameters. Accurate control over the electroplating current is needed especially for the formation of small structures, where pulsed electrodeposition has proven to reduce many unwanted effects. To bring precision into the formation of optimal recipes, a highly flexible current source based on a microcontroller was developed. It allows a large variety of pulse waveforms, as well as maintaining a feedback loop that controls the current and monitors the output voltage, allowing for both galvanostatic (current driven) and potentiostatic (voltage driven) electrodeposition. The system has been implemented with multiple channels, permitting the simultaneous electrodeposition of multiple substrates in parallel. Being based on a microcomputer, the system can be programmed using predefined recipes individually for each channel, or even adapt the recipes during plating. All measurement values are continuously recorded for the purpose of documentation and diagnosis. The current source is based on a high power operational amplifier in a modified Howland current source configuration. This paper describes the functionality of the electrodeposition system, with a focus on the stability of the source current under different electrodeposition current densities and frequencies. The performance and high capability of the system is demonstrated by performing and analyzing two nontrivial plating applications

    The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events

    Get PDF
    The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis. In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb--Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report.Comment: 55 pages, 82 figure

    A two-domain elevator mechanism for sodium/proton antiport

    Get PDF
    Sodium/proton (Na+/H+) antiporters, located at the plasma membrane in every cell, are vital for cell homeostasis1. In humans, their dysfunction has been linked to diseases, such as hypertension, heart failure and epilepsy, and they are well-established drug targets2. The best understood model system for Na+/H+ antiport is NhaA from Escherichia coli1, 3, for which both electron microscopy and crystal structures are available4, 5, 6. NhaA is made up of two distinct domains: a core domain and a dimerization domain. In the NhaA crystal structure a cavity is located between the two domains, providing access to the ion-binding site from the inward-facing surface of the protein1, 4. Like many Na+/H+ antiporters, the activity of NhaA is regulated by pH, only becoming active above pH 6.5, at which point a conformational change is thought to occur7. The only reported NhaA crystal structure so far is of the low pH inactivated form4. Here we describe the active-state structure of a Na+/H+ antiporter, NapA from Thermus thermophilus, at 3 Å resolution, solved from crystals grown at pH 7.8. In the NapA structure, the core and dimerization domains are in different positions to those seen in NhaA, and a negatively charged cavity has now opened to the outside. The extracellular cavity allows access to a strictly conserved aspartate residue thought to coordinate ion binding1, 8, 9 directly, a role supported here by molecular dynamics simulations. To alternate access to this ion-binding site, however, requires a surprisingly large rotation of the core domain, some 20° against the dimerization interface. We conclude that despite their fast transport rates of up to 1,500 ions per second3, Na+/H+ antiporters operate by a two-domain rocking bundle model, revealing themes relevant to secondary-active transporters in general

    Investigating the electrowetting of silver based gas diffusion electrodes during oxygen reduction reaction with electrochemical and optical methods

    Get PDF
    Porous gas diffusion electrodes GDEs are widely used in electrochemical applications where a gaseous reactant is converted to a target product. Important applications for silver based GDEs are the chlor alkali and the CO2 electrolysis processes in which silver catalyzes the oxygen or carbon dioxide reduction reaction. The wetting of the porous GDEs is of utmost importance for the achieved performance of the electrode a completely dry electrode will result in low current densities due to the reduced active surface area while on the other hand, a completely flooded electrode will deteriorate the access of the gaseous reactant. Therefore, we investigated silver based GDEs for the oxygen reduction reaction with different amounts of the hydrophobic agent polytetrafluoroethylene PTFE and analyzed the potential induced wetting behavior electrowetting . The electrolyte breakthrough was recorded by a digital microscope and subsequently evaluated via imaging analysis of the observed breached electrolyte droplets. In order to characterize the wetting state during transition to the steady state, we applied electrochemical impedance spectroscopy measurements and retrieved the double layer capacitance. Our results indicate that a higher overvoltage facilitates the breakthrough of electrolytes through the gas diffusion electrode. Surprisingly, a faster breakthrough of electrolyte was observed for electrodes with higher PTFE content. Porometry measurements revealed that the GDE with low PTFE content has a monomodal pore size distribution, whereas electrodes with higher PTFE amount exhibit a bimodal pore size distribution. In GDEs with monomodal pore size distribution the time in which the double layer capacitance is leveling off correlates with the breakthrough time of the electrolyte. In summary, we emphasize that the wetting of GDEs is a complex interplay of the applied potential, electrode composition, and resulting porous structure which requires further advanced measurements and analysis considering the parameters affecting the wetting behavior as a whol

    European Reference Network for Rare Vascular Diseases (VASCERN) position statement on cerebral screening in adults and children with hereditary haemorrhagic telangiectasia (HHT)

    Get PDF
    Hereditary haemorrhagic telangiectasia (HHT) is a multisystemic vascular dysplasia inherited as an autosomal dominant trait. Approximately 10 % of patients have cerebral vascular malformations, a proportion being cerebral arteriovenous malformations (AVMs) and fistulae that may lead to potentially devastating consequences in case of rupture. On the other hand, detection and treatment related-risks are not negligible, and immediate. While successful treatment can be undertaken in individual cases, current data do not support the treatment of unruptured AVMs, which also present a low risk of bleeding in HHT patients. Screening for these AVMs is therefore controversial. Structured discussions, distinctions of different cerebrovascular abnormalities commonly grouped into an "AVM"bracket, and clear guidance by neurosurgical and neurointerventional radiology colleagues enabled the European Reference Network for Rare Vascular Disorders (VASCERN-HHT) to develop the following agreed Position Statement on cerebral screening: 1) First, we emphasise that neurological symptoms suggestive of cerebral AVMs in HHT patients should be investigated as in general neurological and emergency care practice. Similarly, if an AVM is found accidentally, management approaches should rely on expert discussions on a case-by-case basis and individual risk-benefit evaluation of all therapeutic possibilities for a specific lesion. 2) The current evidence base does not favour the treatment of unruptured cerebral AVMs, and therefore cannot be used to support widespread screening of asymptomatic HHT patients. 3) Individual situations encompass a wide range of personal, cultural and clinical states. In order to enable informed patient choice, and avoid conflicting advice, particularly arising from non-neurovascular interpretations of the evidence base, we suggest that all HHT patients should have the opportunity to discuss knowingly brain screening issues with their healthcare provider. 4) Any screening discussions in asymptomatic individuals should be preceded by informed pre-test review of the latest evidence regarding preventative and therapeutic efficacies of any interventions. The possibility of harm due to detection of, or intervention on, a vascular malformation that would not have necessarily caused any consequence in later life should be stated explicitly. We consider this nuanced Position Statement provides a helpful, evidence-based framework for informed discussions between healthcare providers and patients in an emotionally charged area

    Multiplicity dependence of jet-like two-particle correlations in p-Pb collisions at sNN\sqrt{s_{NN}} = 5.02 TeV

    Full text link
    Two-particle angular correlations between unidentified charged trigger and associated particles are measured by the ALICE detector in p-Pb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV. The transverse-momentum range 0.7 <pT,assoc<pT,trig< < p_{\rm{T}, assoc} < p_{\rm{T}, trig} < 5.0 GeV/cc is examined, to include correlations induced by jets originating from low momen\-tum-transfer scatterings (minijets). The correlations expressed as associated yield per trigger particle are obtained in the pseudorapidity range η<0.9|\eta|<0.9. The near-side long-range pseudorapidity correlations observed in high-multiplicity p-Pb collisions are subtracted from both near-side short-range and away-side correlations in order to remove the non-jet-like components. The yields in the jet-like peaks are found to be invariant with event multiplicity with the exception of events with low multiplicity. This invariance is consistent with the particles being produced via the incoherent fragmentation of multiple parton--parton scatterings, while the yield related to the previously observed ridge structures is not jet-related. The number of uncorrelated sources of particle production is found to increase linearly with multiplicity, suggesting no saturation of the number of multi-parton interactions even in the highest multiplicity p-Pb collisions. Further, the number scales in the intermediate multiplicity region with the number of binary nucleon-nucleon collisions estimated with a Glauber Monte-Carlo simulation.Comment: 23 pages, 6 captioned figures, 1 table, authors from page 17, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/161

    Charge separation relative to the reaction plane in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm NN}}= 2.76 TeV

    Get PDF
    Measurements of charge dependent azimuthal correlations with the ALICE detector at the LHC are reported for Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm NN}} = 2.76 TeV. Two- and three-particle charge-dependent azimuthal correlations in the pseudo-rapidity range η<0.8|\eta| < 0.8 are presented as a function of the collision centrality, particle separation in pseudo-rapidity, and transverse momentum. A clear signal compatible with a charge-dependent separation relative to the reaction plane is observed, which shows little or no collision energy dependence when compared to measurements at RHIC energies. This provides a new insight for understanding the nature of the charge dependent azimuthal correlations observed at RHIC and LHC energies.Comment: 12 pages, 3 captioned figures, authors from page 2 to 6, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/286