1,401 research outputs found

    Does exercise improve glycaemic control in type 1 diabetes? A systematic review and meta-analysis.

    Get PDF
    This is the final published version. Available from PLoS via the DOI in this record.OBJECTIVE: Whilst regular exercise is advocated for people with type 1 diabetes, the benefits of this therapy are poorly delineated. Our objective was to review the evidence for a glycaemic benefit of exercise in type 1 diabetes. RESEARCH DESIGN AND METHODS: Electronic database searches were carried out in MEDLINE, Embase, Cochrane's Controlled Trials Register and SPORTDiscus. In addition, we searched for as yet unpublished but completed trials. Glycaemic benefit was defined as an improvement in glycosylated haemoglobin (HbA1c). Both randomised and non-randomised controlled trials were included. RESULTS: Thirteen studies were identified in the systematic review. Meta-analysis of twelve of these (including 452 patients) demonstrated an HbA1c reduction but this was not statistically significant (standardised mean difference (SMD) -0.25; 95% CI, -0.59 to 0.09). CONCLUSIONS: This meta-analysis does not reveal evidence for a glycaemic benefit of exercise as measured by HbA1c. Reasons for this finding could include increased calorie intake, insulin dose reductions around the time of exercise or lack of power. We also suggest that HbA1c may not be a sensitive indicator of glycaemic control, and that improvement in glycaemic variability may not be reflected in this measure. Exercise does however have other proven benefits in type 1 diabetes, and remains an important part of its management

    Operator theory and function theory in Drury-Arveson space and its quotients

    Full text link
    The Drury-Arveson space Hd2H^2_d, also known as symmetric Fock space or the dd-shift space, is a Hilbert function space that has a natural dd-tuple of operators acting on it, which gives it the structure of a Hilbert module. This survey aims to introduce the Drury-Arveson space, to give a panoramic view of the main operator theoretic and function theoretic aspects of this space, and to describe the universal role that it plays in multivariable operator theory and in Pick interpolation theory.Comment: Final version (to appear in Handbook of Operator Theory); 42 page

    Immediate effect of the COVID-19 pandemic on patient health, health-care use, and behaviours : results from an international survey of people with rheumatic diseases

    Get PDF
    Funding Information: We would like to thank all the clinicians, health-care providers, and patient organisations who helped to develop and disseminate this survey. A full list of all the contributors can be found in the appendix (pp 44?45). Preliminary results were presented at the American College of Rheumatology 2020 conference. The views expressed here are those of the authors and participating members of the COVID-19 Global Rheumatology Alliance and do not necessarily represent the views of the American College of Rheumatology, the European League Against Rheumatism, the UK National Health Service, the National Institute for Health Research, the UK Department of Health, or any other organisation. Funding Information: JSH reports grants from Childhood Arthritis and Rheumatology Research Alliance and Rheumatology Research Alliance; and personal fees from Novartis, Pfizer, and Biogen, outside of the submitted work. JWL reports grants from Pfizer, outside of the submitted work. JAS reports grants and personal fees from Bristol-Myers Squibb; and personal fees from Gilead, Inova Diagnostics, Optum, and Pfizer, outside of the submitted work. CH reports personal fees from AstraZeneca and Aurinia Pharmaceuticals, outside of the submitted work. MJL reports grants from American College of Rheumatology during the conduct of the study and consulting fees from AbbVie, Amgen, Actelion, Boehringer Ingelheim, BMS, Celgene, Gilead, Johnson & Johnson, Mallinckrodt, Novartis, Pfizer, Roche, Sandoz, Sanofi, Sobi, and UCB, outside of the submitted work. SES is supported by the Vasculitis Clinical Research Consortium and Vasculitis Foundation outside of the submitted work. KLD reports grants from Novartis, Sobi, National Institutes of Health, and Horizon Bio, outside of the submitted work. EFM reports that the Liga Portuguesa Contra as Doenças Reumaticas received support for specific activities: grants from Abbvie, Novartis, Janssen-Cilag, Lilly Portugal, Sanofi, Grünenthal SA, MSD, Celgene, Medac, Pharmakern, GAfPA, AMGEN, A Menarini Portugal; grants and non-financial support from Pfizer; and non-financial support from Grünenthal GmbH and Tilray, outside of the submitted work. DPR is the volunteer Vice President of the Canadian Arthritis Patient Alliance, which is primarily supported by independent grants from pharmaceutical companies. DPR reports consulting fees from NovoNordisk Canada and speaking fees and an honoraria from Eli Lilly Canada, outside of the submitted work. DPR also lives with rheumatoid arthritis. SB reports personal fees from Novartis, AbbVie, Pfizer, and Horizon Pharma, outside of the submitted work. RG reports personal fees from AbbVie New Zealand, Cornerstones, Janssen New Zealand; and personal fees and non-financial support from Pfizer New Zealand, (all <$10 000) outside of the submitted work. PMM reports personal fees from Abbvie, Eli Lilly, Janssen, Novartis, Pfizer, and UCB; and grants and personal fees from Orphazyme, outside of the submitted work. PCR reports personal fees from Abbvie, Gilead, Lilly, and Roche; grants and personal fees from Novartis, UCB Pharma, Janssen, and Pfizer; and non-financial support from BMS, outside of the submitted work. PS reports honoraria from being a social media editor for @ACR_Journals, outside of the submitted work. ZSW reports grants from National Institutes of Health, BMS, and Sanofi; and personal fees from Viela Bio and MedPace, outside of the submitted work. JY reports personal fees from Pfizer and Eli Lilly, and grants and personal fees from Astra Zeneca, outside of the submitted work. ES is a Board Member of the Canadian Arthritis Patient Alliance, which is a patient-run, volunteer-based organisation whose activities are primarily supported by independent grants from pharmaceutical companies. All other authors declare no competing interests. Publisher Copyright: © 2021 Elsevier LtdBackground: The impact and consequences of the COVID-19 pandemic on people with rheumatic disease are unclear. We developed the COVID-19 Global Rheumatology Alliance Patient Experience Survey to assess the effects of the COVID-19 pandemic on people with rheumatic disease worldwide. Methods: Survey questions were developed by key stakeholder groups and disseminated worldwide through social media, websites, and patient support organisations. Questions included demographics, rheumatic disease diagnosis, COVID-19 diagnosis, adoption of protective behaviours to mitigate COVID-19 exposure, medication access and changes, health-care access and communication with rheumatologists, and changes in employment or schooling. Adults age 18 years and older with inflammatory or autoimmune rheumatic diseases were eligible for inclusion. We included participants with and without a COVID-19 diagnosis. We excluded participants reporting only non-inflammatory rheumatic diseases such as fibromyalgia or osteoarthritis. Findings: 12 117 responses to the survey were received between April 3 and May 8, 2020, and of these, 10 407 respondents had included appropriate age data. We included complete responses from 9300 adults with rheumatic disease (mean age 46·1 years; 8375 [90·1%] women, 893 [9·6%] men, and 32 [0·3%] participants who identified as non-binary). 6273 (67·5%) of respondents identified as White, 1565 (16·8%) as Latin American, 198 (2·1%) as Black, 190 (2·0%) as Asian, and 42 (0·5%) as Native American or Aboriginal or First Nation. The most common rheumatic disease diagnoses included rheumatoid arthritis (3636 [39·1%] of 9300), systemic lupus erythematosus (2882 [31·0%]), and Sjögren's syndrome (1290 [13·9%]). Most respondents (6921 [82·0%] of 8441) continued their antirheumatic medications as prescribed. Almost all (9266 [99·7%] of 9297) respondents adopted protective behaviours to limit SARS-CoV-2 exposure. A change in employment status occurred in 2524 (27·1%) of 9300) of respondents, with a 13·6% decrease in the number in full-time employment (from 4066 to 3514). Interpretation: People with rheumatic disease maintained therapy and followed public health advice to mitigate the risks of COVID-19. Substantial employment status changes occurred, with potential implications for health-care access, medication affordability, mental health, and rheumatic disease activity. Funding: American College of Rheumatology.publishersversionPeer reviewe

    Portable Optical Fiber Probe-Based Spectroscopic Scanner for Rapid Cancer Diagnosis: A New Tool for Intraoperative Margin Assessment

    Get PDF
    There continues to be a significant clinical need for rapid and reliable intraoperative margin assessment during cancer surgery. Here we describe a portable, quantitative, optical fiber probe-based, spectroscopic tissue scanner designed for intraoperative diagnostic imaging of surgical margins, which we tested in a proof of concept study in human tissue for breast cancer diagnosis. The tissue scanner combines both diffuse reflectance spectroscopy (DRS) and intrinsic fluorescence spectroscopy (IFS), and has hyperspectral imaging capability, acquiring full DRS and IFS spectra for each scanned image pixel. Modeling of the DRS and IFS spectra yields quantitative parameters that reflect the metabolic, biochemical and morphological state of tissue, which are translated into disease diagnosis. The tissue scanner has high spatial resolution (0.25 mm) over a wide field of view (10 cm×10 cm), and both high spectral resolution (2 nm) and high spectral contrast, readily distinguishing tissues with widely varying optical properties (bone, skeletal muscle, fat and connective tissue). Tissue-simulating phantom experiments confirm that the tissue scanner can quantitatively measure spectral parameters, such as hemoglobin concentration, in a physiologically relevant range with a high degree of accuracy (<5% error). Finally, studies using human breast tissues showed that the tissue scanner can detect small foci of breast cancer in a background of normal breast tissue. This tissue scanner is simpler in design, images a larger field of view at higher resolution and provides a more physically meaningful tissue diagnosis than other spectroscopic imaging systems currently reported in literatures. We believe this spectroscopic tissue scanner can provide real-time, comprehensive diagnostic imaging of surgical margins in excised tissues, overcoming the sampling limitation in current histopathology margin assessment. As such it is a significant step in the development of a platform technology for intraoperative management of cancer, a clinical problem that has been inadequately addressed to date.Case Comprehensive Cancer Center. Tissue Procurement, Histology and Immunohistochemistry Core Facility (P30 CA43703)National Cancer Institute (U.S.) (R01-CA140288)National Cancer Institute (U.S.) (R01-CA97966)National Center for Research Resources (U.S.) (S10-RR031845)National Center for Research Resources (U.S.) (P41-RR02594

    Energy and macronutrient intakes in preschool children in urban areas of Ho Chi Minh City, Vietnam

    Get PDF
    Background: An increasing prevalence of overweight and obesity has been documented in preschool children in Ho Chi Minh City (HCMC), Vietnam. However, little is known about what preschool children in HCMC eat or how well their nutrient intake meets nutrient recommendations. This study aims to describe the energy and macronutrient intake and compare these nutrient intakes with the recommendations for Vietnamese children aged four to five years. Methods: The data comes from the baseline measurement of a one year follow-up study on obesity in 670 children attending kindergartens in HCMC. Dietary information for each child at the school and home settings was collected using Food Frequency Questionnaires (FFQs), by interviewing teachers and parents or main caregivers. The average energy and nutrient intake in a day was calculated. The proportion of children with energy intake from macronutrients meeting or exceeding the recommendations was estimated based on the 2006 recommended daily allowance (RDA) for Vietnamese children in this age group. Results: The dietary intake of the participants contained more energy from protein and fat, particularly animal protein and fat, and less energy from carbohydrates, than the RDA. Most children (98.1%) had mean energy intake from protein greater than the recommended level of 15%, and no child obtained energy from animal fat that was in accordance with the recommendation of less than 30% of the total fat intake. Nearly one half of children (46.5%) consumed less than the advised range of mean energy intake from carbohydrate (60%–70%). Conclusion: In this preschool child population in HCMC, in which obesity is emerging as major public health problem, there is an imbalance in dietary intake. Healthy eating programs need to be developed as a part of an obesity prevention program for young children in HCMC

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore