10 research outputs found

    Stratification of Culture-Proven Early-Onset Sepsis Cases by the Neonatal Early-Onset Sepsis Calculator: An Individual Patient Data Meta-Analysis.

    Get PDF
    To provide a comprehensive assessment of case stratification by the Neonatal Early-Onset Sepsis (EOS) Calculator, a novel tool for reducing unnecessary antibiotic treatment. A systematic review with individual patient data meta-analysis was conducted, extending PROSPERO record CRD42018116188. Cochrane, PubMed/MEDLINE, EMBASE, Web of Science, Google Scholar, and major conference proceedings were searched from 2011 through May 1, 2020. Original data studies including culture-proven EOS case(s) with EOS Calculator application, independent from EOS Calculator development, and including representative birth cohorts were included. Relevant (individual patient) data were extracted from full-text and data queries. The main outcomes were the proportions of EOS cases assigned to risk categories by the EOS Calculator at initial assessment and within 12 hours. Evidence quality was assessed using Newcastle-Ottawa scale, Critical Appraisal and Data Extraction for Systematic Reviews of Prediction Modelling Studies, and GRADE tools. Among 543 unique search results, 18 were included, totaling more than 459 000 newborns. Among 234 EOS cases, EOS Calculator application resulted in initial assignments to (strong consideration of) empiric antibiotic administration for 95 (40.6%; 95% CI, 34.2%-47.2%), more frequent vital signs for 36 (15.4%; 95% CI, 11.0%-20.7%), and routine care for 103 (44.0%; 95% CI, 37.6%-50.6%). By 12 hours of age, these proportions changed to 143 (61.1%; 95% CI, 54.5%-67.4%), 26 (11.1%; 95% CI, 7.4%-15.9%), and 65 (27.8%; 95% CI, 22.1%-34.0%) of 234 EOS cases, respectively. EOS Calculator application assigns frequent vital signs or routine care to a substantial proportion of EOS cases. Clinical vigilance remains essential for all newborns

    Association of Use of the Neonatal Early-Onset Sepsis Calculator With Reduction in Antibiotic Therapy and Safety: A Systematic Review and Meta-analysis.

    No full text
    The neonatal early-onset sepsis (EOS) calculator is a clinical risk stratification tool increasingly used to guide the use of empirical antibiotics for newborns. Evidence on the effectiveness and safety of the EOS calculator is essential to inform clinicians considering implementation. To assess the association between management of neonatal EOS guided by the neonatal EOS calculator (compared with conventional management strategies) and reduction in antibiotic therapy for newborns. Electronic searches in MEDLINE, Embase, Web of Science, and Google Scholar were conducted from 2011 (introduction of the EOS calculator model) through January 31, 2019. All studies with original data that compared management guided by the EOS calculator with conventional management strategies for allocating antibiotic therapy to newborns suspected to have EOS were included. Following PRISMA-P guidelines, relevant data were extracted from full-text articles and supplements. CHARMS (Checklist for Critical Appraisal and Data Extraction for Systematic Reviews of Prediction Modeling Studies) and GRADE (Grades of Recommendation, Assessment, Development and Evaluation) tools were used to assess the risk of bias and quality of evidence. Meta-analysis using a random-effects model was conducted for studies with separate cohorts for EOS calculator and conventional management strategies. The difference in percentage of newborns treated with empirical antibiotics for suspected or proven EOS between management guided by the EOS calculator and conventional management strategies. Safety-related outcomes involved missed cases of EOS, readmissions, treatment delay, morbidity, and mortality. Thirteen relevant studies analyzing a total of 175 752 newborns were included. All studies found a substantially lower relative risk (range, 3%-60%) for empirical antibiotic therapy, favoring the EOS calculator. Meta-analysis revealed a relative risk of antibiotic use of 56% (95% CI, 53%-59%) in before-after studies including newborns regardless of exposure to chorioamnionitis. Evidence on safety was limited, but proportions of missed cases of EOS were comparable between management guided by the EOS calculator (5 of 18 [28%]) and conventional management strategies (8 of 28 [29%]) (pooled odds ratio, 0.96; 95% CI, 0.26-3.52; P = .95). Use of the neonatal EOS calculator is associated with a substantial reduction in the use of empirical antibiotics for suspected EOS. Available evidence regarding safety of the use of the EOS calculator is limited, but shows no indication of inferiority compared with conventional management strategies

    Long-baseline neutrino oscillation physics potential of the DUNE experiment: DUNE Collaboration

    No full text
    The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is determined, based on a full simulation, reconstruction, and event selection of the far detector and a full simulation and parameterized analysis of the near detector. Detailed uncertainties due to the flux prediction, neutrino interaction model, and detector effects are included. DUNE will resolve the neutrino mass ordering to a precision of 5σ, for all δCP values, after 2 years of running with the nominal detector design and beam configuration. It has the potential to observe charge-parity violation in the neutrino sector to a precision of 3σ (5σ) after an exposure of 5 (10) years, for 50% of all δCP values. It will also make precise measurements of other parameters governing long-baseline neutrino oscillation, and after an exposure of 15 years will achieve a similar sensitivity to sin 22 θ13 to current reactor experiments. © 2020, The Author(s)

    Deep Underground Neutrino Experiment (DUNE), far detector technical design report, volume IV: far detector single-phase technology

    Get PDF
    The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay—these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. Central to achieving DUNE's physics program is a far detector that combines the many tens-of-kiloton fiducial mass necessary for rare event searches with sub-centimeter spatial resolution in its ability to image those events, allowing identification of the physics signatures among the numerous backgrounds. In the single-phase liquid argon time-projection chamber (LArTPC) technology, ionization charges drift horizontally in the liquid argon under the influence of an electric field towards a vertical anode, where they are read out with fine granularity. A photon detection system supplements the TPC, directly enhancing physics capabilities for all three DUNE physics drivers and opening up prospects for further physics explorations. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume IV presents an overview of the basic operating principles of a single-phase LArTPC, followed by a description of the DUNE implementation. Each of the subsystems is described in detail, connecting the high-level design requirements and decisions to the overriding physics goals of DUNE

    Deep underground neutrino experiment (DUNE) near detector conceptual design report

    No full text
    The Deep Underground Neutrino Experiment (DUNE) is an international, world-class experiment aimed at exploring fundamental questions about the universe that are at the forefront of astrophysics and particle physics research. DUNE will study questions pertaining to the preponderance of matter over antimatter in the early universe, the dynamics of supernovae, the subtleties of neutrino interaction physics, and a number of beyond the Standard Model topics accessible in a powerful neutrino beam. A critical component of the DUNE physics program involves the study of changes in a powerful beam of neutrinos, i.e., neutrino oscillations, as the neutrinos propagate a long distance. The experiment consists of a near detector, sited close to the source of the beam, and a far detector, sited along the beam at a large distance. This document, the DUNE Near Detector Conceptual Design Report (CDR), describes the design of the DUNE near detector and the science program that drives the design and technology choices. The goals and requirements underlying the design, along with projected performance are given. It serves as a starting point for a more detailed design that will be described in future documents. © 2021 by the authors. Licensee MDPI, Basel, Switzerland
    corecore