60 research outputs found

    A multicenter randomized-controlled trial of hypothermic oxygenated perfusion (HOPE) for human liver grafts before transplantation

    Get PDF
    Background &amp; Aims: Machine perfusion is a novel method intended to optimize livers before transplantation. However, its effect on morbidity within a 1-year period after transplantation has remained unclear. Methods: In this multicenter controlled trial, we randomly assigned livers donated after brain death (DBD) for liver transplantation (LT). Livers were either conventionally cold stored (control group), or cold stored and subsequently treated by 1-2 h hypothermic oxygenated perfusion (HOPE) before implantation (HOPE group). The primary endpoint was the occurrence of at least one post-transplant complication per patient, graded by the Clavien score of ≥III, within 1-year after LT. The comprehensive complication index (CCI), laboratory parameters, as well as duration of hospital and intensive care unit stay, graft survival, patient survival, and biliary complications served as secondary endpoints. Results: Between April 2015 and August 2019, we randomized 177 livers, resulting in 170 liver transplantations (85 in the HOPE group and 85 in the control group). The number of patients with at least one Clavien ≥III complication was 46/85 (54.1%) in the control group and 44/85 (51.8%) in the HOPE group (odds ratio 0.91; 95% CI 0.50-1.66; p = 0.76). Secondary endpoints were also not significantly different between groups. A post hoc analysis revealed that liver-related Clavien ≥IIIb complications occurred less frequently in the HOPE group compared to the control group (risk ratio 0.26; 95% CI 0.07-0.77; p = 0.027). Likewise, graft failure due to liver-related complications did not occur in the HOPE group, but occurred in 7% (6 of 85) of the control group (log-rank test, p = 0.004, Gray test, p = 0.015). Conclusions: HOPE after cold storage of DBD livers resulted in similar proportions of patients with at least one Clavien ≥III complication compared to controls. Exploratory findings suggest that HOPE decreases the risk of severe liver graft-related events. Impact and implications: This randomized controlled phase III trial is the first to investigate the impact of hypothermic oxygenated perfusion (HOPE) on cumulative complications within a 12-month period after liver transplantation. Compared to conventional cold storage, HOPE did not have a significant effect on the number of patients with at least one Clavien ≥III complication. However, we believe that HOPE may have a beneficial effect on the quantity of complications per patient, based on its application leading to fewer severe liver graft-related complications, and to a lower risk of liver-related graft loss. The HOPE approach can be applied easily after organ transport during recipient hepatectomy. This appears fundamental for wide acceptance since concurring perfusion technologies need either perfusion at donor sites or continuous perfusion during organ transport, which are much costlier and more laborious. We conclude therefore that the post hoc findings of this trial should be further validated in future studies.</p

    A multicenter randomized-controlled trial of hypothermic oxygenated perfusion (HOPE) for human liver grafts before transplantation

    Get PDF
    Background &amp; Aims: Machine perfusion is a novel method intended to optimize livers before transplantation. However, its effect on morbidity within a 1-year period after transplantation has remained unclear. Methods: In this multicenter controlled trial, we randomly assigned livers donated after brain death (DBD) for liver transplantation (LT). Livers were either conventionally cold stored (control group), or cold stored and subsequently treated by 1-2 h hypothermic oxygenated perfusion (HOPE) before implantation (HOPE group). The primary endpoint was the occurrence of at least one post-transplant complication per patient, graded by the Clavien score of ≥III, within 1-year after LT. The comprehensive complication index (CCI), laboratory parameters, as well as duration of hospital and intensive care unit stay, graft survival, patient survival, and biliary complications served as secondary endpoints. Results: Between April 2015 and August 2019, we randomized 177 livers, resulting in 170 liver transplantations (85 in the HOPE group and 85 in the control group). The number of patients with at least one Clavien ≥III complication was 46/85 (54.1%) in the control group and 44/85 (51.8%) in the HOPE group (odds ratio 0.91; 95% CI 0.50-1.66; p = 0.76). Secondary endpoints were also not significantly different between groups. A post hoc analysis revealed that liver-related Clavien ≥IIIb complications occurred less frequently in the HOPE group compared to the control group (risk ratio 0.26; 95% CI 0.07-0.77; p = 0.027). Likewise, graft failure due to liver-related complications did not occur in the HOPE group, but occurred in 7% (6 of 85) of the control group (log-rank test, p = 0.004, Gray test, p = 0.015). Conclusions: HOPE after cold storage of DBD livers resulted in similar proportions of patients with at least one Clavien ≥III complication compared to controls. Exploratory findings suggest that HOPE decreases the risk of severe liver graft-related events. Impact and implications: This randomized controlled phase III trial is the first to investigate the impact of hypothermic oxygenated perfusion (HOPE) on cumulative complications within a 12-month period after liver transplantation. Compared to conventional cold storage, HOPE did not have a significant effect on the number of patients with at least one Clavien ≥III complication. However, we believe that HOPE may have a beneficial effect on the quantity of complications per patient, based on its application leading to fewer severe liver graft-related complications, and to a lower risk of liver-related graft loss. The HOPE approach can be applied easily after organ transport during recipient hepatectomy. This appears fundamental for wide acceptance since concurring perfusion technologies need either perfusion at donor sites or continuous perfusion during organ transport, which are much costlier and more laborious. We conclude therefore that the post hoc findings of this trial should be further validated in future studies.</p

    Лапаротомия в системе лечения перитонитов

    Get PDF
    ПЕРИТОНИТ /ХИРБРЮШИНЫ БОЛЕЗНИ /ХИРЛАПАРОТОМИЯХИРУРГИЧЕСКИЕ ОПЕРАЦИИ /МЕТОДЫРЕЛАПАРОТОМИ

    The impact of surgical delay on resectability of colorectal cancer: An international prospective cohort study

    Get PDF
    AIM: The SARS-CoV-2 pandemic has provided a unique opportunity to explore the impact of surgical delays on cancer resectability. This study aimed to compare resectability for colorectal cancer patients undergoing delayed versus non-delayed surgery. METHODS: This was an international prospective cohort study of consecutive colorectal cancer patients with a decision for curative surgery (January-April 2020). Surgical delay was defined as an operation taking place more than 4 weeks after treatment decision, in a patient who did not receive neoadjuvant therapy. A subgroup analysis explored the effects of delay in elective patients only. The impact of longer delays was explored in a sensitivity analysis. The primary outcome was complete resection, defined as curative resection with an R0 margin. RESULTS: Overall, 5453 patients from 304 hospitals in 47 countries were included, of whom 6.6% (358/5453) did not receive their planned operation. Of the 4304 operated patients without neoadjuvant therapy, 40.5% (1744/4304) were delayed beyond 4 weeks. Delayed patients were more likely to be older, men, more comorbid, have higher body mass index and have rectal cancer and early stage disease. Delayed patients had higher unadjusted rates of complete resection (93.7% vs. 91.9%, P = 0.032) and lower rates of emergency surgery (4.5% vs. 22.5%, P < 0.001). After adjustment, delay was not associated with a lower rate of complete resection (OR 1.18, 95% CI 0.90-1.55, P = 0.224), which was consistent in elective patients only (OR 0.94, 95% CI 0.69-1.27, P = 0.672). Longer delays were not associated with poorer outcomes. CONCLUSION: One in 15 colorectal cancer patients did not receive their planned operation during the first wave of COVID-19. Surgical delay did not appear to compromise resectability, raising the hypothesis that any reduction in long-term survival attributable to delays is likely to be due to micro-metastatic disease

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac

    Use of anticoagulants and antiplatelet agents in stable outpatients with coronary artery disease and atrial fibrillation. International CLARIFY registry

    Get PDF

    Measurement of the W-boson mass in pp collisions at √s=7 TeV with the ATLAS detector

    Get PDF
    A measurement of the mass of the W boson is presented based on proton–proton collision data recorded in 2011 at a centre-of-mass energy of 7 TeV with the ATLAS detector at the LHC, and corresponding to 4.6 fb−1 of integrated luminosity. The selected data sample consists of 7.8×106 candidates in the W→μν channel and 5.9×106 candidates in the W→eν channel. The W-boson mass is obtained from template fits to the reconstructed distributions of the charged lepton transverse momentum and of the W boson transverse mass in the electron and muon decay channels, yielding mW=80370±7 (stat.)±11(exp. syst.) ±14(mod. syst.) MeV =80370±19MeV, where the first uncertainty is statistical, the second corresponds to the experimental systematic uncertainty, and the third to the physics-modelling systematic uncertainty. A measurement of the mass difference between the W+ and W−bosons yields mW+−mW−=−29±28 MeV

    Genetic mechanisms of critical illness in COVID-19.

    Get PDF
    Host-mediated lung inflammation is present1, and drives mortality2, in the critical illness caused by coronavirus disease 2019 (COVID-19). Host genetic variants associated with critical illness may identify mechanistic targets for therapeutic development3. Here we report the results of the GenOMICC (Genetics Of Mortality In Critical Care) genome-wide association study in 2,244 critically ill patients with COVID-19 from 208 UK intensive care units. We have identified and replicated the following new genome-wide significant associations: on chromosome 12q24.13 (rs10735079, P = 1.65 × 10-8) in a gene cluster that encodes antiviral restriction enzyme activators (OAS1, OAS2 and OAS3); on chromosome 19p13.2 (rs74956615, P = 2.3 × 10-8) near the gene that encodes tyrosine kinase 2 (TYK2); on chromosome 19p13.3 (rs2109069, P = 3.98 ×  10-12) within the gene that encodes dipeptidyl peptidase 9 (DPP9); and on chromosome 21q22.1 (rs2236757, P = 4.99 × 10-8) in the interferon receptor gene IFNAR2. We identified potential targets for repurposing of licensed medications: using Mendelian randomization, we found evidence that low expression of IFNAR2, or high expression of TYK2, are associated with life-threatening disease; and transcriptome-wide association in lung tissue revealed that high expression of the monocyte-macrophage chemotactic receptor CCR2 is associated with severe COVID-19. Our results identify robust genetic signals relating to key host antiviral defence mechanisms and mediators of inflammatory organ damage in COVID-19. Both mechanisms may be amenable to targeted treatment with existing drugs. However, large-scale randomized clinical trials will be essential before any change to clinical practice

    Catálogo Taxonômico da Fauna do Brasil: setting the baseline knowledge on the animal diversity in Brazil

    Get PDF
    The limited temporal completeness and taxonomic accuracy of species lists, made available in a traditional manner in scientific publications, has always represented a problem. These lists are invariably limited to a few taxonomic groups and do not represent up-to-date knowledge of all species and classifications. In this context, the Brazilian megadiverse fauna is no exception, and the Catálogo Taxonômico da Fauna do Brasil (CTFB) (http://fauna.jbrj.gov.br/), made public in 2015, represents a database on biodiversity anchored on a list of valid and expertly recognized scientific names of animals in Brazil. The CTFB is updated in near real time by a team of more than 800 specialists. By January 1, 2024, the CTFB compiled 133,691 nominal species, with 125,138 that were considered valid. Most of the valid species were arthropods (82.3%, with more than 102,000 species) and chordates (7.69%, with over 11,000 species). These taxa were followed by a cluster composed of Mollusca (3,567 species), Platyhelminthes (2,292 species), Annelida (1,833 species), and Nematoda (1,447 species). All remaining groups had less than 1,000 species reported in Brazil, with Cnidaria (831 species), Porifera (628 species), Rotifera (606 species), and Bryozoa (520 species) representing those with more than 500 species. Analysis of the CTFB database can facilitate and direct efforts towards the discovery of new species in Brazil, but it is also fundamental in providing the best available list of valid nominal species to users, including those in science, health, conservation efforts, and any initiative involving animals. The importance of the CTFB is evidenced by the elevated number of citations in the scientific literature in diverse areas of biology, law, anthropology, education, forensic science, and veterinary science, among others

    Machine perfusion in liver transplantation

    Full text link
    Although liver transplantation is a true success story, many patients still die awaiting an organ. The increasing need for liver grafts therefore remains an unsolved challenge to the transplant community. To address this, transplant donor criteria have been expanded and, for example, more liver grafts with significant steatosis or from donors with circulatory death are being used. These marginal grafts, however, carry an increased risk of graft-associated complications, such as primary nonfunction, delayed graft function, or late biliary injuries. Therefore, reliable assessment of graft viability before use is essential for further success. To achieve this, machine liver perfusion, a procedure developed more than 50 years ago but almost forgotten at the end of the last century, is again of great interest. We describe in this review the clinical most applied machine perfusion techniques, their mechanistic background, and a novel concept of combining immediate organ assessment during hypothermic oxygenated perfusion, followed by an extended phase of normothermic machine perfusion, with simultaneous ex situ treatment of the perfused liver. Such a new approach may allow the pool of usable livers to dramatically increase and improve outcomes for recipients
    corecore