404 research outputs found
Accumulation and fate of nano- and micro-plastics and associated contaminants in organisms
This is the author accepted manuscript. The final version is available from Elsevier via the DOI in this record.Following a decade of research on the environmental impacts of microplastics, a knowledge gap remains on the processes by which micro and nanoplastics pass across biological barriers, enter cells and are subject to biological mechanisms. Here we summarize available literature on the accumulation of microplastics and their associated contaminants in a variety of organisms including humans. Most data on the accumulation of microplastics in both field and lab studies are for marine invertebrates. Microplastics accumulation data for insects, birds, marine mammals and sea turtles are scarce due to methodological issues. There is no conclusive evidence for the mode of accumulation of microplastics in either mammals or humans. The mechanism of chemical partitioning, role of contaminants associated with plastics, and mode of action of both nano- and micro-plastics and associated chemicals in a range of organisms and associated compartments/tissues also requires further research.Natural Environment Research Council (NERC)Queensland Department of Healt
UV sources and plastic composition influence microplastic surface degradation: Implications for plastic weathering studies
This is the final version. Available on open access from Elsevier via the DOI in this recordMicroplastic surface properties are dynamic in the environment, as weathering, primarily through photooxidation due to ultraviolet light (UV) exposure, modifies surface chemistry and surface roughness, which can affect the fate, transport and reactivity of microplastics, and therefore any potential environmental risk they may pose. This study aims to investigate and characterise the effect of different UV radiation sources that are typically used in weathering studies (UVA-340 fluorescent lamps, xenon-arc lamps and natural sunlight) on two key properties of microplastics: surface roughness and oxidation level. High- and low-density polyethylene, polypropylene and polystyrene microplastic nurdles (<5 mm) were weathered and characterised using Atomic Force Microscopy and Fourier-Transform Infrared spectroscopy. After two weeks, UVA light was found to significantly increase the carbonyl index of the subject high-density polyethylene and decrease its surface roughness. The subject low-density polyethylene was found to increase in carbonyl index when exposed to all three light sources for two weeks, and reduced in surface roughness when exposed to both xenon-arc and UVA light. Xenon-arc light increased surface roughness on the subject polypropylene after two weeks exposure. The subject polystyrene significantly increased in carbonyl index when exposed to xenon-arc light for two weeks but decreased in surface roughness when exposed to UVA light. Surface oxidation was found to be dependent on polymer type, UV source and additive content, with the data showing a relationship between surface roughness, surface shading and additive content. The results from this study highlight the complexity of microplastic weathering processes and how metrics such as carbonyl index must be applied with caution when estimating how long a plastic has been in the environment.QUEX InstituteQueensland Health, AustraliaNatural Environment Research Council (NERC
Quantitative Analysis of Selected Plastics in High-Commercial-Value Australian Seafood by Pyrolysis Gas Chromatography Mass Spectrometry
This is the final version. Available on open access from the American Chemical Society via the DOI in this recordMicroplastic contamination of the marine environment is widespread, but the extent to which the marine food web is contaminated is not yet known. The aims of this study were to go beyond visual identification techniques and develop and apply a simple seafood sample cleanup, extraction, and quantitative analysis method using pyrolysis gas chromatography mass spectrometry to improve the detection of plastic contamination. This method allows the identification and quantification of polystyrene, polyethylene, polyvinyl chloride, polypropylene, and poly(methyl methacrylate) in the edible portion of five different seafood organisms: oysters, prawns, squid, crabs, and sardines. Polyvinyl chloride was detected in all samples and polyethylene at the highest total concentration of between 0.04 and 2.4 mg g-1 of tissue. Sardines contained the highest total plastic mass concentration (0.3 mg g-1 tissue) and squid the lowest (0.04 mg g-1 tissue). Our findings show that the total concentration of plastics is highly variable among species and that microplastic concentration differs between organisms of the same species. The sources of microplastic exposure, such as packaging and handling with consequent transference and adherence to the tissues, are discussed. This method is a major development in the standardization of plastic quantification techniques used in seafood.University of QueenslandUniversity of ExeterNatural Environment Research Council (NERC)Queensland Department of Healt
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
X-ray emission from the Sombrero galaxy: discrete sources
We present a study of discrete X-ray sources in and around the
bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival
Chandra observations with a total exposure of ~200 ks. With a detection limit
of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30
kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler
et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS
observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray
binaries (LMXBs). We quantify the differential luminosity functions (LFs) for
both the detected GC and field LMXBs, whose power-low indices (~1.1 for the
GC-LF and ~1.6 for field-LF) are consistent with previous studies for
elliptical galaxies. With precise sky positions of the GCs without a detected
X-ray source, we further quantify, through a fluctuation analysis, the GC LF at
fainter luminosities down to 1E35 erg/s. The derived index rules out a
faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent
findings in several elliptical galaxies and the bulge of M31. On the other
hand, the 2-6 keV unresolved emission places a tight constraint on the field
LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101
sources in the halo of Sombrero. The presence of these sources cannot be
interpreted as galactic LMXBs whose spatial distribution empirically follows
the starlight. Their number is also higher than the expected number of cosmic
AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray
surveys. We suggest that either the cosmic X-ray background is unusually high
in the direction of Sombrero, or a distinct population of X-ray sources is
present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy
A search for new physics is performed in events with two same-sign isolated
leptons, hadronic jets, and missing transverse energy in the final state. The
analysis is based on a data sample corresponding to an integrated luminosity of
4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of
7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of
140 increase in integrated luminosity over previously published results. The
observed yields agree with the standard model predictions and thus no evidence
for new physics is found. The observations are used to set upper limits on
possible new physics contributions and to constrain supersymmetric models. To
facilitate the interpretation of the data in a broader range of new physics
scenarios, information on the event selection, detector response, and
efficiencies is provided.Comment: Published in Physical Review Letter
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
A CLINICAL STUDY OF INHALANT ANAESTHESIA IN DOGS
A clinical trial was undertaken using three different inhalant anaesthetic agents and one intravenous anaesthetic agent in dogs undergoing routine desexing surgery. Healthy adult dogs undergoing either ovariohysterectomy or castration were assessed as to their demeanour, with the more excitable dogs being placed in groups receiving premedication with acepromazine and morphine. All dogs were then randomly assigned an anaesthetic agent for induction of general anaesthesia. The agents were the inhalants halothane, isoflurane and sevoflurane, and the intravenous agent propofol. Inhalant inductions were undertaken using a tight fitting mask attached to a standard anaesthetic machine with a rebreathing circuit, with the maximum dose of inhalant available from a standard vaporiser. Propofol inductions were undertaken via intravenous catheter. Dogs induced with propofol were randomly assigned one of the three inhalant agents for maintenance. Those induced by inhalant agent were maintained using the same agent. The surgical procedure was undertaken in standard fashion, as was recovery from anaesthesia. All dogs received the non-steroidal anti-inflammatory agent meloxicam. Data collection was divided into three stages: induction, maintenance, and recovery from anaesthesia. Variables measured at induction of anaesthesia were time to intubation, number of intubation attempts, tolerance of mask, quality of induction and quality of transfer to the maintenance stage. Standard variables for monitoring of anaesthesia were recorded throughout the maintenance of anaesthesia. Variables measured at recovery were time to righting, time to standing and quality of recovery. The mean time to intubation when using the newer inhalant sevoflurane (196.2 ± 14.8sec, mean ± SE) was not significantly different to that for halothane (221.4 ± 14.0sec) or isoflurane (172.4 ± 15.0sec). Time to intubation with isoflurane was significantly faster than with halothane. Mean time to intubation with propofol (85.4 ± 7.7sec) was significantly faster than that for any of the three inhalants. Choice of inhalant had no effect on quality of induction. The use of premedication significantly improved the quality of induction. The use of propofol for induction likewise significantly improved the quality of induction. Standard cardiorespiratory variables measured during the maintenance phase of anaesthesia remained within normal clinical ranges for all three inhalants, and were therefore not further analysed. Choice of inhalant agent had no significant effect on the time to righting or standing in recovery. The use of propofol for induction had no effect on these variables. Animals placed in groups receiving premedication had significantly longer times to righting and standing. The oesophageal temperature at the end of the procedure had a significant effect on times to righting and standing, with lower temperatures contributing to slower recoveries. Independent of procedure time, male dogs had shorter times to righting than female dogs
- …