24 research outputs found

    Surgical Versus Medical Treatment for Diabetic Macular Edema: A Review

    Get PDF
    We aimed to compare the results of pars plana vitrectomy (PPV) with internal limiting membrane (ILM) peeling, an alternative therapeutic strategy, with those of medical treatment for chronic macular edema. We conducted a review of the literature on the microscopic, anatomical, and functional reasons for performing PPV with ILM peeling in patients with diabetic macular edema (DME). We searched the PubMed database for articles published between 2000 and 2017. We used the medical subject heading “vitrectomy diabetic macular edema†and the keywords “diabetic macular edemaâ€, “internal limiting membrane peelingâ€, “pars plana vitrectomyâ€, “diabetic retinopathyâ€, and “optical coherence tomographyâ€. Analysis of the literature revealed that cytokines, vascular endothelial growth factor, reactive oxygen species (ROS), and advanced glycation end-products (AGEs) play a unique role in DME. The vitreous cavity serves as a physiological reservoir for all inflammatory molecules. AGE receptors are localized at the footplates of Müller cells and the external limiting membrane (ELM). The footplates of Müller cells are in contact with the ILM, which suggests that they might be responsible for the structural damage (i.e., thickening) observed in the ILM of patients with DME. Therefore, PPV could allow a reduction of cytokines and pro-inflammatory molecules from the vitreous cavity. ILM peeling could eliminate not only the physical traction of a thickened structure, but also the natural reservoir of AGEs, ROS, and inflammatory molecules. PPV with ILM peeling is a surgical option that should be considered when treating patients with chronic DME

    Oculocardiac Reflex During Intravitreal Injection

    Get PDF
    Oculocardiac reflex (OCR) has been described to occur with mechanical manipulation of the eye, eyelids or orbit. There are no reports in the literature of OCR during intravitreal injection (IVI). This may be due to the fact that heart rate is not monitored during the procedure. We aimed to evaluate OCR during IVI. A total of 532 patients were enrolled in the study in Asociacion para Evitar la Ceguera en Mexico. Mexico City, Mexico. IVI was performed on one eye in every patient with diabetic retinopathy (DR), age related macular degeneration (AMD) or choroidal neovascularization (CNV) secondary to pathological myopia. Heart rate was monitored with a pulse oximeter before, during and after injection. OCR was defined as a 20% decrease or more of basal heart rate. The population enrolled included 270 females and 262 males with mean age of 63.8 years. A decrease in heart rate of 20% or more occurred in 18 patients during IVI (3.3%; 95% confidence interval 1.85% and 4.92%). OCR was asymptomatic in these patients. OCR occurred in 3.3% of our patients during IVI. Hence, OCR must be considered when performing IVI

    Intravitreal Bevacizumab (Avastin) for Diabetic Retinopathy: The 2010 GLADAOF Lecture

    Get PDF
    This paper demonstrates multiple benefits of intravitreal bevacizumab (IVB) on diabetic retinopathy (DR) including diabetic macular edema (DME) and proliferative diabetic retinopathy (PDR) at 24 months of followup. This is a retrospective multicenter interventional comparative case series of intravitreal injections of 1.25 or 2.5 mg of bevacizumab for DME, PDR without tractional retinal detachment (TRD), and patients who experienced the development or progression of TRD after an intravitreal injection of 1.25 or 2.5 mg of bevacizumab before vitrectomy for the management of PDR. The results indicate that IVB injections may have a beneficial effect on macular thickness and visual acuity (VA) in diffuse DME. Therefore, in the future this new therapy could complement focal/grid laser photocoagulation in DME. In PDR, this new option could be an adjuvant agent to panretina photocoagulation so that more selective therapy may be applied. Finally, TRD in PDR may occur or progress after IVB used as an adjuvant to vitrectomy. Surgery should be performed 4 days after IVB. Most patients had poorly controlled diabetes mellitus associated with elevated HbA1c, insulin administration, PDR refractory to panretinal photocoagulation, and longer time between IVB and vitrectomy

    Localization and broadband follow-up of the gravitational-wave transient GW150914

    Get PDF
    A gravitational-wave (GW) transient was identified in data recorded by the Advanced Laser Interferometer Gravitational-wave Observatory (LIGO) detectors on 2015 September 14. The event, initially designated G184098 and later given the name GW150914, is described in detail elsewhere. By prior arrangement, preliminary estimates of the time, significance, and sky location of the event were shared with 63 teams of observers covering radio, optical, near-infrared, X-ray, and gamma-ray wavelengths with ground- and space-based facilities. In this Letter we describe the low-latency analysis of the GW data and present the sky localization of the first observed compact binary merger. We summarize the follow-up observations reported by 25 teams via private Gamma-ray Coordinates Network circulars, giving an overview of the participating facilities, the GW sky localization coverage, the timeline, and depth of the observations. As this event turned out to be a binary black hole merger, there is little expectation of a detectable electromagnetic (EM) signature. Nevertheless, this first broadband campaign to search for a counterpart of an Advanced LIGO source represents a milestone and highlights the broad capabilities of the transient astronomy community and the observing strategies that have been developed to pursue neutron star binary merger events. Detailed investigations of the EM data and results of the EM follow-up campaign are being disseminated in papers by the individual teams

    Localization and Broadband Follow-up of the Gravitational-wave Transient GW150914

    Get PDF
    A gravitational-wave (GW) transient was identified in data recorded by the Advanced Laser Interferometer Gravitational-wave Observatory (LIGO) detectors on 2015 September 14. The event, initially designated G184098 and later given the name GW150914, is described in detail elsewhere. By prior arrangement, preliminary estimates of the time, significance, and sky location of the event were shared with 63 teams of observers covering radio, optical, near-infrared, X-ray, and gamma-ray wavelengths with ground- and space-based facilities. In this Letter we describe the low-latency analysis of the GW data and present the sky localization of the first observed compact binary merger. We summarize the follow-up observations reported by 25 teams via private Gamma-ray Coordinates Network circulars, giving an overview of the participating facilities, the GW sky localization coverage, the timeline, and depth of the observations. As this event turned out to be a binary black hole merger, there is little expectation of a detectable electromagnetic (EM) signature. Nevertheless, this first broadband campaign to search for a counterpart of an Advanced LIGO source represents a milestone and highlights the broad capabilities of the transient astronomy community and the observing strategies that have been developed to pursue neutron star binary merger events. Detailed investigations of the EM data and results of the EM follow-up campaign are being disseminated in papers by the individual teams. </p

    Localization and broadband follow-up of the gravitational-wave transient GW150914

    Get PDF
    A gravitational-wave transient was identified in data recorded by the Advanced LIGO detectors on 2015 September 14. The event candidate, initially designated G184098 and later given the name GW150914, is described in detail elsewhere. By prior arrangement, preliminary estimates of the time, significance, and sky location of the event were shared with 63 teams of observers covering radio, optical, near-infrared, X-ray, and gamma-ray wavelengths with ground- and space-based facilities. In this Letter we describe the low-latency analysis of the gravitational wave data and present the sky localization of the first observed compact binary merger. We summarize the follow-up observations reported by 25 teams via private Gamma-ray Coordinates Network Circulars, giving an overview of the participating facilities, the gravitational wave sky localization coverage, the timeline and depth of the observations. As this event turned out to be a binary black hole merger, there is little expectation of a detectable electromagnetic signature. Nevertheless, this first broadband campaign to search for a counterpart of an Advanced LIGO source represents a milestone and highlights the broad capabilities of the transient astronomy community and the observing strategies that have been developed to pursue neutron star binary merger events. Detailed investigations of the electromagnetic data and results of the electromagnetic follow-up campaign will be disseminated in the papers of the individual teams

    Oculocardiac Reflex During Intravitreal Injection

    Get PDF
    Oculocardiac reflex (OCR) has been described to occur with mechanical manipulation of the eye, eyelids or orbit. There are no reports in the literature of OCR during intravitreal injection (IVI). This may be due to the fact that heart rate is not monitored during the procedure. We aimed to evaluate OCR during IVI. A total of 532 patients were enrolled in the study in Asociacion para Evitar la Ceguera en Mexico. Mexico City, Mexico. IVI was performed on one eye in every patient with diabetic retinopathy (DR), age related macular degeneration (AMD) or choroidal neovascularization (CNV) secondary to pathological myopia. Heart rate was monitored with a pulse oximeter before, during and after injection. OCR was defined as a 20% decrease or more of basal heart rate. The population enrolled included 270 females and 262 males with mean age of 63.8 years. A decrease in heart rate of 20% or more occurred in 18 patients during IVI (3.3%; 95% confidence interval 1.85% and 4.92%). OCR was asymptomatic in these patients. OCR occurred in 3.3% of our patients during IVI. Hence, OCR must be considered when performing IVI

    Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial

    No full text
    BACKGROUND: The automated screening of patients at risk of developing diabetic retinopathy represents an opportunity to improve their midterm outcome and lower the public expenditure associated with direct and indirect costs of common sight-threatening complications of diabetes. OBJECTIVE: This study aimed to develop and evaluate the performance of an automated deep learning–based system to classify retinal fundus images as referable and nonreferable diabetic retinopathy cases, from international and Mexican patients. In particular, we aimed to evaluate the performance of the automated retina image analysis (ARIA) system under an independent scheme (ie, only ARIA screening) and 2 assistive schemes (ie, hybrid ARIA plus ophthalmologist screening), using a web-based platform for remote image analysis to determine and compare the sensibility and specificity of the 3 schemes. METHODS: A randomized controlled experiment was performed where 17 ophthalmologists were asked to classify a series of retinal fundus images under 3 different conditions. The conditions were to (1) screen the fundus image by themselves (solo); (2) screen the fundus image after exposure to the retina image classification of the ARIA system (ARIA answer); and (3) screen the fundus image after exposure to the classification of the ARIA system, as well as its level of confidence and an attention map highlighting the most important areas of interest in the image according to the ARIA system (ARIA explanation). The ophthalmologists’ classification in each condition and the result from the ARIA system were compared against a gold standard generated by consulting and aggregating the opinion of 3 retina specialists for each fundus image. RESULTS: The ARIA system was able to classify referable vs nonreferable cases with an area under the receiver operating characteristic curve of 98%, a sensitivity of 95.1%, and a specificity of 91.5% for international patient cases. There was an area under the receiver operating characteristic curve of 98.3%, a sensitivity of 95.2%, and a specificity of 90% for Mexican patient cases. The ARIA system performance was more successful than the average performance of the 17 ophthalmologists enrolled in the study. Additionally, the results suggest that the ARIA system can be useful as an assistive tool, as sensitivity was significantly higher in the experimental condition where ophthalmologists were exposed to the ARIA system’s answer prior to their own classification (93.3%), compared with the sensitivity of the condition where participants assessed the images independently (87.3%; P=.05). CONCLUSIONS: These results demonstrate that both independent and assistive use cases of the ARIA system present, for Latin American countries such as Mexico, a substantial opportunity toward expanding the monitoring capacity for the early detection of diabetes-related blindness

    Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial

    No full text
    BACKGROUND: The automated screening of patients at risk of developing diabetic retinopathy represents an opportunity to improve their midterm outcome and lower the public expenditure associated with direct and indirect costs of common sight-threatening complications of diabetes. OBJECTIVE: This study aimed to develop and evaluate the performance of an automated deep learning-based system to classify retinal fundus images as referable and nonreferable diabetic retinopathy cases, from international and Mexican patients. In particular, we aimed to evaluate the performance of the automated retina image analysis (ARIA) system under an independent scheme (ie, only ARIA screening) and 2 assistive schemes (ie, hybrid ARIA plus ophthalmologist screening), using a web-based platform for remote image analysis to determine and compare the sensibility and specificity of the 3 schemes. METHODS: A randomized controlled experiment was performed where 17 ophthalmologists were asked to classify a series of retinal fundus images under 3 different conditions. The conditions were to (1) screen the fundus image by themselves (solo); (2) screen the fundus image after exposure to the retina image classification of the ARIA system (ARIA answer); and (3) screen the fundus image after exposure to the classification of the ARIA system, as well as its level of confidence and an attention map highlighting the most important areas of interest in the image according to the ARIA system (ARIA explanation). The ophthalmologists' classification in each condition and the result from the ARIA system were compared against a gold standard generated by consulting and aggregating the opinion of 3 retina specialists for each fundus image. RESULTS: The ARIA system was able to classify referable vs nonreferable cases with an area under the receiver operating characteristic curve of 98%, a sensitivity of 95.1%, and a specificity of 91.5% for international patient cases. There was an area under the receiver operating characteristic curve of 98.3%, a sensitivity of 95.2%, and a specificity of 90% for Mexican patient cases. The ARIA system performance was more successful than the average performance of the 17 ophthalmologists enrolled in the study. Additionally, the results suggest that the ARIA system can be useful as an assistive tool, as sensitivity was significantly higher in the experimental condition where ophthalmologists were exposed to the ARIA system's answer prior to their own classification (93.3%), compared with the sensitivity of the condition where participants assessed the images independently (87.3%; P=.05). CONCLUSIONS: These results demonstrate that both independent and assistive use cases of the ARIA system present, for Latin American countries such as Mexico, a substantial opportunity toward expanding the monitoring capacity for the early detection of diabetes-related blindness
    corecore