41 research outputs found

    Contactless photoconductivity-detected electron spin resonance of P donors in isotopically purified Si

    Full text link
    Coherence times of electron spins bound to phosphorus donors have been measured, using a standard Hahn echo technique, to be up to 20 ms in isotopically pure silicon with [P]=1014 = 10^{14} cm3^{-3} and at temperatures 4\leq 4 K. Although such times are exceptionally long for electron spins in the solid state, they are nevertheless limited by donor electron spin-spin interactions. Suppressing such interactions requires even lower donor concentrations, which lie below the detection limit for typical electron spin resonance (ESR) spectrometers. Here we describe an alternative method for phosphorus donor ESR detection, exploiting the spin-to-charge conversion provided by the optical donor bound exciton transition. We characterise the method and its dependence on laser power and use it to measure a coherence time of T2=130T_2 = 130 ms for one of the purest silicon samples grown to-date ([P]=5×1011 = 5\times 10^{11} cm3^{-3}). We then benchmark this result using an alternative application of the donor bound exciton transition: optically polarising the donor spins before using conventional ESR detection at 1.7~K for a sample with [P]=4×1012 = 4\times10^{12} cm3^{-3}, and measuring in this case a T2T_2 of 350 ms

    Is respiratory viral infection really an important trigger of asthma exacerbations in children?

    Get PDF
    We performed a prospective cohort study from September 2003 to December 2004 to delineate attributing the effect of different respiratory viral infections including newly discovered ones to asthma exacerbations in children in Hong Kong. One hundred and fourteen children aged 6–14 years with chronic stable asthma and on regular inhaled steroid were monitored for respiratory symptoms over a full calendar year from recruitment. They would attend the study clinic if peak expiratory flow rate decreased to below 80% of their baselines, if they met a predefined symptom score, or if parents subjectively felt them developing a cold. Virological diagnosis using virus culture, antigen detection, and polymerase chain reaction methods on nasal swab specimens would be attempted for all these visits irrespective of triggers. Physician diagnosed outcome of each episode was documented. Three hundred and five episodes of respiratory illnesses were captured in the cohort. Nasal specimens were available in 166 episodes, 92 of which were diagnosed as asthma exacerbations, and 74 non-asthma related episodes. Respiratory viruses were detected in 61 of 166 episodes (36.7%). There was no significant difference in virus detection rate between asthma exacerbations (32 out of 97 episodes, 34.8%) and non-asthma respiratory illnesses (29 out of 79 episodes, 39.2%). Although newly discovered respiratory viruses were identified in these episodes, rhinovirus was the commonest organism associated with both asthma exacerbations and non-asthma related episodes. Plausible explanations for much lower virus detection rate than previously reported include improved personal hygiene and precautionary measures taken during respiratory tract infections in the immediate post-severe acute respiratory syndrome period together with a significant contribution of other adverse factors like environmental air pollution. We conclude that not all viral infections in children with asthma lead to an asthma exacerbation and the attributing effect of different triggers of asthma exacerbations in children vary across different time periods and across different localities

    The development and validation of a scoring tool to predict the operative duration of elective laparoscopic cholecystectomy

    Get PDF
    Background: The ability to accurately predict operative duration has the potential to optimise theatre efficiency and utilisation, thus reducing costs and increasing staff and patient satisfaction. With laparoscopic cholecystectomy being one of the most commonly performed procedures worldwide, a tool to predict operative duration could be extremely beneficial to healthcare organisations. Methods: Data collected from the CholeS study on patients undergoing cholecystectomy in UK and Irish hospitals between 04/2014 and 05/2014 were used to study operative duration. A multivariable binary logistic regression model was produced in order to identify significant independent predictors of long (> 90 min) operations. The resulting model was converted to a risk score, which was subsequently validated on second cohort of patients using ROC curves. Results: After exclusions, data were available for 7227 patients in the derivation (CholeS) cohort. The median operative duration was 60 min (interquartile range 45–85), with 17.7% of operations lasting longer than 90 min. Ten factors were found to be significant independent predictors of operative durations > 90 min, including ASA, age, previous surgical admissions, BMI, gallbladder wall thickness and CBD diameter. A risk score was then produced from these factors, and applied to a cohort of 2405 patients from a tertiary centre for external validation. This returned an area under the ROC curve of 0.708 (SE = 0.013, p  90 min increasing more than eightfold from 5.1 to 41.8% in the extremes of the score. Conclusion: The scoring tool produced in this study was found to be significantly predictive of long operative durations on validation in an external cohort. As such, the tool may have the potential to enable organisations to better organise theatre lists and deliver greater efficiencies in care

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Device fabrication and transport measurements of FinFETs built with 28Si SOI wafers towards donor qubits in silicon

    No full text
    We report fabrication of transistors in a FinFET geometry using isotopically purified silicon-28 -on-insulator (28-SOI) substrates. Donor electron spin coherence in natural silicon is limited by spectral diffusion due to the residual 29Si nuclear spin bath, making isotopically enriched nuclear spin-free 28Si substrates a promising candidate for forming spin quantum bit devices. The FinFET architecture is fully compatible with single-ion implant detection for donor-based qubits, and the donor spin-state readout through electrical detection of spin resonance. We describe device processing steps and discuss results on electrical transport measurements at 0.3 K

    Successful Treatment of Drug-Resistant Seizures Secondary to Ring 20 Mosaicism with Perampanel as an Add-On Antiepileptic Drug

    No full text
    We report a girl with drug-resistant seizures, progressive behavioral changes, and cognitive decline. Investigations showed abnormal EEG with frequent high-voltage bifrontotemporal sharp and slow waves, especially during sleep. Seizures were difficult to control, despite the usage of various antiepileptic drugs. Perampanel as an add-on antiepileptic drug appeared efficacious. Due to the recognizable pattern of seizures and EEG findings, a karyotype study was performed which revealed 46 chromosomes with a ring 20 chromosome mosaicism. Ring 20 chromosome is associated with drug-resistant refractory seizures, cognitive decline, and behavioral problems. This case highlights the difficulty and challenge faced in managing drug-resistant refractory seizures associated with ring 20 chromosome. While ring 20 chromosome is often underdiagnosed, one should have a high index of awareness and suspicion of such rare epilepsy syndrome, so that an early diagnosis can be made.Peer Reviewe
    corecore