74 research outputs found

    Band gap reduction in InNxSb1-x alloys: Optical absorption, k . P modeling, and density functional theory

    Get PDF
    Using infrared absorption, the room temperature band gap of InSb is found to reduce from 174 (7.1 μm) to 85 meV (14.6 μm) upon incorporation of up to 1.13% N, a reduction of ∼79 meV/%N. The experimentally observed band gap reduction in molecular-beam epitaxial InNSb thin films is reproduced by a five band k ⋅· P band anticrossing model incorporating a nitrogen level, EN, 0.75 eV above the valence band maximum of the host InSb and an interaction coupling matrix element between the host conduction band and the N level of β = 1.80 eV. This observation is consistent with the presented results from hybrid density functional theory

    Deception studies manipulating centrally acting performance modifiers: a review.

    Get PDF
    Athletes anticipatorily set and continuously adjust pacing strategies before and during events to produce optimal performance. Selfregulation ensures maximal effort is exerted in correspondence with the end point of exercise, while preventing physiological changes that are detrimental and disruptive to homeostatic control. The integration of feedforward and feedback information, together with the proposed brain_s performance modifiers is said to be fundamental to this anticipatory and continuous regulation of exercise. The manipulation of central, regulatory internal and external stimuli has been a key focus within deception research, attempting to influence the self-regulation of exercise and induce improvements in performance. Methods of manipulating performance modifiers such as unknown task end point, deceived duration or intensity feedback, self-belief, or previous experience create a challenge within research, as although they contextualize theoretical propositions, there are few ecological and practical approaches which integrate theory with practice. In addition, the different methods and measures demonstrated in manipulation studies have produced inconsistent results. This review examines and critically evaluates the current methods of how specific centrally controlled performance modifiers have been manipulated, within previous deception studies. From the 31 studies reviewed, 10 reported positive effects on performance, encouraging future investigations to explore the mechanisms responsible for influencing pacing and consequently how deceptive approaches can further facilitate performance. The review acts to discuss the use of expectation manipulation not only to examine which methods of deception are successful in facilitating performance but also to understand further the key components used in the regulation of exercise and performance

    Reduced firing rates of high threshold motor units in response to eccentric overload

    Get PDF
    Acute responses of motor units were investigated during submaximal voluntary isometric tasks following eccentric overload (EO) and constant load (CL) knee extension resistance exercise. Ten healthy resistance-trained participants performed four experimental test sessions separated by 5 days over a 20 day period. Two sessions involved constant load and the other two used eccentric overload. EO and CL used both sessions for different target knee eccentric extension phases; one at 2 sec and the other at 4 sec. Maximal voluntary contractions (MVC) and isometric trapezoid efforts for 10 sec at 70% MVC were completed before and after each intervention and decomposed electromyography was used to measure motor unit firing rate. The firing rate of later recruited, high-threshold motor units declined following the 2-sec EO but was maintained following 2sec CL (P < 0.05), whereas MUFR for all motor units were maintained for both loading types following 4-sec extension phases. MVC and rate of force development where maintained following both EO and CL and 2 and 4 sec phases. This study demonstrates a slower firing rate of high-threshold motor units following fast eccentric overload while MVC was maintained. This suggests that there was a neuromuscular stimulus without cost to the force-generating capacity of the knee extensors. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society

    A second generation cervico-vaginal lavage device shows similar performance as its preceding version with respect to DNA yield and HPV DNA results

    Get PDF
    Contains fulltext : 118480.pdf (publisher's version ) (Open Access)BACKGROUND: Attendance rates of cervical screening programs can be increased by offering HPV self-sampling to non-attendees. Acceptability, DNA yield, lavage volumes and choice of hrHPV test can influence effectiveness of the self-sampling procedures and could therefore play a role in recruiting non-attendees. To increase user-friendliness, a frequently used lavage sampler was modified. In this study, we compared this second generation lavage device with the first generation device within similar birth cohorts. METHODS: Within a large self-sampling cohort-study among non-responders of the Dutch cervical screening program, a subset of 2,644 women received a second generation self-sampling lavage device, while 11,977 women, matched for age and ZIP-code, received the first generation model. The second generation device was different in shape, color, lavage volume, and packaging, in comparison to its first generation model. The Cochran's test was used to compare both devices for hrHPV positivity rate and response rate. To correct for possible heterogeneity between age and ZIP codes in both groups the Breslow-Day test of homogeneity was used. A T-test was utilized to compare DNA yields of the obtained material in both groups. RESULTS: Median DNA yields were 90.4 mug/ml (95% CI 83.2-97.5) and 91.1 mug/ml (95% CI 77.8-104.4, p= 0.726) and hrHPV positivity rates were 8.2% and 6.9% (p= 0.419) per sample self-collected by the second - and the first generation of the device (p= 0.726), respectively. In addition, response rates were comparable for the two models (35.4% versus 34.4%, p= 0.654). CONCLUSIONS: Replacing the first generation self-sampling device by an ergonomically improved, second generation device resulted in equal DNA yields, comparable hrHPV positivity rates and similar response rates. Therefore, it can be concluded that the clinical performance of the first and second generation models are similar. Moreover, participation of non-attendees in cervical cancer screening is probably not predominantly determined by the type of self-collection device

    Physiological and Psychological Effects of Deception on Pacing Strategy and Performance: A Review

    Get PDF
    The aim of an optimal pacing strategy during exercise is to enhance performance whilst ensuring physiological limits are not surpassed, which has been shown to result in a metabolic reserve at the end of the exercise. There has been debate surrounding the theoretical models that have been proposed to explain how pace is regulated, with more recent research investigating a central control of exercise regulation. Deception has recently emerged as a common, practical approach to manipulate key variables during exercise. There are a number of ways in which deception interventions have been designed, each intending to gain particular insights into pacing behaviour and performance. Deception methodologies can be conceptualised according to a number of dimensions such as deception timing (prior to or during exercise), presentation frequency (blind, discontinuous or continuous) and type of deception (performance, biofeedback or environmental feedback). However, research evidence on the effects of deception has been perplexing and the use of complex designs and varied methodologies makes it difficult to draw any definitive conclusions about how pacing strategy and performance are affected by deception. This review examines existing research in the area of deception and pacing strategies, and provides a critical appraisal of the different methodological approaches used to date. It is hoped that this analysis will inform the direction and methodology of future investigations in this area by addressing the mechanisms through which deception impacts upon performance and by elucidating the potential application of deception techniques in training and competitive settings

    Why Don't We Ask? A Complementary Method for Assessing the Status of Great Apes

    Get PDF
    Species conservation is difficult. Threats to species are typically high and immediate. Effective solutions for counteracting these threats, however, require synthesis of high quality evidence, appropriately targeted activities, typically costly implementation, and rapid re-evaluation and adaptation. Conservation management can be ineffective if there is insufficient understanding of the complex ecological, political, socio-cultural, and economic factors that underlie conservation threats. When information about these factors is incomplete, conservation managers may be unaware of the most urgent threats or unable to envision all consequences of potential management strategies. Conservation research aims to address the gap between what is known and what knowledge is needed for effective conservation. Such research, however, generally addresses a subset of the factors that underlie conservation threats, producing a limited, simplistic, and often biased view of complex, real world situations. A combination of approaches is required to provide the complete picture necessary to engage in effective conservation. Orangutan conservation (Pongo spp.) offers an example: standard conservation assessments employ survey methods that focus on ecological variables, but do not usually address the socio-cultural factors that underlie threats. Here, we evaluate a complementary survey method based on interviews of nearly 7,000 people in 687 villages in Kalimantan, Indonesia. We address areas of potential methodological weakness in such surveys, including sampling and questionnaire design, respondent biases, statistical analyses, and sensitivity of resultant inferences. We show that interview-based surveys can provide cost-effective and statistically robust methods to better understand poorly known populations of species that are relatively easily identified by local people. Such surveys provide reasonably reliable estimates of relative presence and relative encounter rates of such species, as well as quantifying the main factors that threaten them. We recommend more extensive use of carefully designed and implemented interview surveys, in conjunction with more traditional field methods

    Between-day repeatability of lower limb EMG measurement during running and walking

    Get PDF
    There are minimal data describing the between-day repeatability of EMG measurements during running. Furthermore, there are no data characterising the repeatability of surface EMG measurement from the adductor muscles, during running or walking. The purpose of this study was to report on the consistency of EMG measurement for both running and walking across a comprehensive set of lower limb muscles, including adductor magnus, longus and gracilis. Data were collected from 12 lower limb muscles during overground running and walking on two separate days. The coefficient of multiple correlation (CMC) was used to quantify waveform similarity across the two sessions for signals normalised to either maximal voluntary isometric contraction (MVIC) or mean/peak signal magnitude. For running, the data showed good or excellent repeatability (CMC=0.87-0.96) for all muscles apart from gracilis and biceps femoris using the MVIC method. Similar levels of repeatability were observed for walking. Importantly, using the peak/mean method as an alternative to the MVIC method, resulted in only marginal improvements in repeatability. The proposed protocol facilitated the collection of repeatable EMG data during running and walking and therefore could be used in future studies investigating muscle patterns during gait

    Pacing and Decision Making in Sport and Exercise: The Roles of Perception and Action in the Regulation of Exercise Intensity

    Get PDF
    In pursuit of optimal performance, athletes and physical exercisers alike have to make decisions about how and when to invest their energy. The process of pacing has been associated with the goal-directed regulation of exercise intensity across an exercise bout. The current review explores divergent views on understanding underlying mechanisms of decision making in pacing. Current pacing literature provides a wide range of aspects that might be involved in the determination of an athlete's pacing strategy, but lacks in explaining how perception and action are coupled in establishing behaviour. In contrast, decision-making literature rooted in the understanding that perception and action are coupled provides refreshing perspectives on explaining the mechanisms that underlie natural interactive behaviour. Contrary to the assumption of behaviour that is managed by a higher-order governor that passively constructs internal representations of the world, an ecological approach is considered. According to this approach, knowledge is rooted in the direct experience of meaningful environmental objects and events in individual environmental processes. To assist a neuropsychological explanation of decision making in exercise regulation, the relevance of the affordance competition hypothesis is explored. By considering pacing as a behavioural expression of continuous decision making, new insights on underlying mechanisms in pacing and optimal performance can be developed. © 2014 Springer International Publishing Switzerland

    First Observation of Heavy Baryons \Sigma_b and \Sigma_b^*

    Get PDF
    We report an observation of new bottom baryons produced in proton-antiproton collisions at the Tevatron. Using 1.1 fb^{-1} of data collected by the CDF II detector, we observe four \Lambda_b^0\pi^{\pm} resonances in the fully reconstructed decay mode \Lambda_b^0 \to \Lambda_c^+ \pi^-, where \Lambda_c^+ \to p K^- \pi^+. We interpret these states as the \Sigma_b^{(*)\pm} baryons and measure the following masses: m_{\Sigma_b^+} = 5807.8^{+2.0}_{-2.2}(stat.) \pm 1.7(syst.) MeV/c^2, m_{\Sigma_b^-} = 5815.2 \pm 1.0(stat.) \pm 1.7(syst.) MeV/c^2, and m(\Sigma_b^*) - m(\Sigma_b) = 21.2^{+2.0}_{-1.9}(stat.) ^{+0.4}_{-0.3}(syst.) MeV/c^2.Comment: 7 Pages, 2 Figures, 2 Tables. Submitted to Phys. Rev. Let
    • …
    corecore