124 research outputs found

    Quality of care of patients with type-2 diabetes in Galicia (NW Spain) [OBTEDIGA project]

    Get PDF
    [Abstract] Aims:  The aim of this study was to describe the degree of compliance of agreed practices with reference to primary care patients with Type 2 diabetes of 40 years old and older in Galicia (NW Spain). Methods:  A total of 108 primary care physicians were selected at random from the totality of doctors. Each physician selected 30 patients at random from their patients suffering from diabetes of 40 years old or older. External observers gathered information from each patient’s medical record regarding their characteristics, condition and degree of compliance of selected indicators of good practice. Results:  Group of physicians participated in this study had a mean age of 50 years (standard deviation = 3.9); 48% of them were females; and 17.5% involved in medical residents training. A total of 3078 diabetic patients were included in the study: mean age = 69 years (SD = 10.9), 47.6% women, presence of high blood pressure (72%), hypercholesterolaemia (56%), and regular smokers (10.3%). Compliance with selected indicators such as foot examination (14%), ophthalmological examination (30.6%), abdominal circumference measurement (6.1%), measurement of total or LDL-cholesterol (78.1), blood pressure measurement (84.8), glycosylated haemoglobin measurement < 7% (54.3%) was observed. Adequate monitoring in cases of high blood pressure and hypercholesterolaemia were 34.2% and 27.4%, respectively. Variability between physicians differs according to the different indicators, with interquartile range for compliance of between 16.4 and 66%. Conclusions:  There is a wide margin for improvement in the adaptation of clinical practice to recommendations for diabetic patients. The large variation existing in certain indicators would suggest that certain control objectives are less demanding than advisable in those that comply least, while low compliance and low variability in other indicators point to structural problems or unsatisfactory training of doctors

    Long-term effect of 2 intensive statin regimens on treatment and incidence of cardiovascular events in familial hypercholesterolemia : The SAFEHEART study

    Get PDF
    Funding: This study was supported by FundaciĂłn Hipercolesterolemia Familiar; Grant G03/181 Grant 08-2008 Centro Nacional de Investigaci?n Cardiovascular (CNIC).Background: Maximal doses of potent statins are the basement of treatment of familial hypercholesterolemia (FH). Little is known about the use of different statin regimens in FH. Objectives: The objectives of the study were to describe the treatment changes and low-density lipoprotein cholesterol (LDL-C) goal achievement with atorvastatin (ATV) and rosuvastatin (RV) in the SAFEHEART cohort, as well as to analyze the incidence of atherosclerotic cardiovascular events (ACVEs) and changes in the cardiovascular risk. Methods: SAFEHEART is a prospective follow-up nationwide cohort study in a molecularly defined FH population. The patients were contacted on a yearly basis to obtain relevant changes in life habits, medication, and ACVEs. Results: A total of 1939 patients were analyzed. Median follow-up was 6.6 years (5-10). The estimated 10-year risk according the SAFEHEART risk equation was 1.61 (0.67-3.39) and 1.22 (0.54-2.93) at enrollment for ATV and RV, respectively (P <.001). There were no significant differences at the follow-up: 1.29 (0.54-2.82) and 1.22 (0.54-2.76) in the ATV and RV groups, respectively (P =.51). Sixteen percent of patients in primary prevention with ATV and 18% with RV achieved an LDL-C <100 mg/dL and 4% in secondary prevention with ATV and 5% with RV achieved an LDL-C <70 mg/dL. The use of ezetimibe was marginally greater in the RV group. One hundred sixty ACVEs occurred during follow-up, being its incidence rate 1.1 events/100 patient-years in the ATV group and 1.2 in the RV group (P =.58). Conclusion: ATV and RV are 2 high-potency statins widely used in FH. Although the reduction in LDL-C levels was greater with RV than with ATV, the superiority of RV for reducing ACVEs was not demonstrated

    The exposure of the hybrid detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The "hybrid" detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data collected during operations, such as the status of the fluorescence detector, background light and atmospheric conditions, that are used in both simulation and reconstruction.Comment: Paper accepted by Astroparticle Physic

    Atmospheric effects on extensive air showers observed with the Surface Detector of the Pierre Auger Observatory

    Get PDF
    Atmospheric parameters, such as pressure (P), temperature (T) and density, affect the development of extensive air showers initiated by energetic cosmic rays. We have studied the impact of atmospheric variations on extensive air showers by means of the surface detector of the Pierre Auger Observatory. The rate of events shows a ~10% seasonal modulation and ~2% diurnal one. We find that the observed behaviour is explained by a model including the effects associated with the variations of pressure and density. The former affects the longitudinal development of air showers while the latter influences the Moliere radius and hence the lateral distribution of the shower particles. The model is validated with full simulations of extensive air showers using atmospheric profiles measured at the site of the Pierre Auger Observatory.Comment: 24 pages, 9 figures, accepted for publication in Astroparticle Physic

    The Fluorescence Detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.Comment: 53 pages. Submitted to Nuclear Instruments and Methods in Physics Research Section

    Evidence for a mixed mass composition at the `ankle' in the cosmic-ray spectrum

    Get PDF
    We report a first measurement for ultra-high energy cosmic rays of the correlation between the depth of shower maximum and the signal in the water Cherenkov stations of air-showers registered simultaneously by the fluorescence and the surface detectors of the Pierre Auger Observatory. Such a correlation measurement is a unique feature of a hybrid air-shower observatory with sensitivity to both the electromagnetic and muonic components. It allows an accurate determination of the spread of primary masses in the cosmic-ray flux. Up till now, constraints on the spread of primary masses have been dominated by systematic uncertainties. The present correlation measurement is not affected by systematics in the measurement of the depth of shower maximum or the signal in the water Cherenkov stations. The analysis relies on general characteristics of air showers and is thus robust also with respect to uncertainties in hadronic event generators. The observed correlation in the energy range around the `ankle' at lg⁡(E/eV)=18.5−19.0\lg(E/{\rm eV})=18.5-19.0 differs significantly from expectations for pure primary cosmic-ray compositions. A light composition made up of proton and helium only is equally inconsistent with observations. The data are explained well by a mixed composition including nuclei with mass A>4A > 4. Scenarios such as the proton dip model, with almost pure compositions, are thus disfavoured as the sole explanation of the ultrahigh-energy cosmic-ray flux at Earth.Comment: Published version. Added journal reference and DOI. Added Report Numbe

    Coping with poachers in European stalked barnacle fisheries: Insights from a stakeholder workshop.

    Get PDF
    In January 2020, a stakeholder workshop was organized as a knowledge sharing strategy among European stalked barnacle fisheries. Management of this fishery differs greatly among regions and ranges from less organized and governed at large scales (>100 km, coasts of SW Portugal and Brittany in France) to highly participatory systems which are co-managed at small spatial scales (10â€Čs km and less, Galicia and Asturias). Discussions revealed that poaching is ubiquitous, hard to eradicate, and adapts to all types of management. The stakeholders identified some key management initiatives in the fight against poaching: granting professional harvesters with exclusive access to the resource, increasing social capital among harvesters through tenure systems (e.g. Territorial Use Rights in Fisheries) that empower them as stewards of their resource and intensi- fication of surveillance with the active participation of the harvesters. Furthermore, increased cooperation be- tween fishers associations and regional fisheries authorities, improved legal frameworks, adoption of new technologies and the implementation of market-based solutions can also help coping with this systemic problem

    Anisotropy studies around the galactic centre at EeV energies with the Auger Observatory

    Get PDF
    Data from the Pierre Auger Observatory are analyzed to search for anisotropies near the direction of the Galactic Centre at EeV energies. The exposure of the surface array in this part of the sky is already significantly larger than that of the fore-runner experiments. Our results do not support previous findings of localized excesses in the AGASA and SUGAR data. We set an upper bound on a point-like flux of cosmic rays arriving from the Galactic Centre which excludes several scenarios predicting sources of EeV neutrons from Sagittarius AA. Also the events detected simultaneously by the surface and fluorescence detectors (the `hybrid' data set), which have better pointing accuracy but are less numerous than those of the surface array alone, do not show any significant localized excess from this direction.Comment: Matches published versio

    Estimation of neutron-equivalent dose in organs of patients undergoing radiotherapy by the use of a novel online digital detector.

    Get PDF
    Neutron peripheral contamination in patients undergoing high-energy photon radiotherapy is considered as a risk factor for secondary cancer induction. Organ-specific neutron-equivalent dose estimation is therefore essential for a reasonable assessment of these associated risks. This work aimed to develop a method to estimate neutron-equivalent doses in multiple organs of radiotherapy patients. The method involved the convolution, at 16 reference points in an anthropomorphic phantom, of the normalized Monte Carlo neutron fluence energy spectra with the kerma and energy-dependent radiation weighting factor. This was then scaled with the total neutron fluence measured with passive detectors, at the same reference points, in order to obtain the equivalent doses in organs. The latter were correlated with the readings of a neutron digital detector located inside the treatment room during phantom irradiation. This digital detector, designed and developed by our group, integrates the thermal neutron fluence. The correlation model, applied to the digital detector readings during patient irradiation, enables the online estimation of neutron-equivalent doses in organs. The model takes into account the specific irradiation site, the field parameters (energy, field size, angle incidence, etc) and the installation (linac and bunker geometry). This method, which is suitable for routine clinical use, will help to systematically generate the dosimetric data essential for the improvement of current risk-estimation models

    Upper limit on the cosmic-ray photon fraction at EeV energies from the Pierre Auger Observatory

    Get PDF
    From direct observations of the longitudinal development of ultra-high energy air showers performed with the Pierre Auger Observatory, upper limits of 3.8%, 2.4%, 3.5% and 11.7% (at 95% c.l.) are obtained on the fraction of cosmic-ray photons above 2, 3, 5 and 10 EeV (1 EeV = 10^18 eV) respectively. These are the first experimental limits on ultra-high energy photons at energies below 10 EeV. The results complement previous constraints on top-down models from array data and they reduce systematic uncertainties in the interpretation of shower data in terms of primary flux, nuclear composition and proton-air cross-section.Comment: 20 pages, 7 figures, 2 tables. Minor changes. Accepted by Astroparticle Physic
    • 

    corecore