207 research outputs found

    Development of a Momentum Determined Electron Beam in the 1 -45 GeV Range

    Get PDF
    A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10^6 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging system based on drift chambers with 160 micron resolution was able to measure relative electron beam momentum precisely. The resolution sigma_p p was 0.13% at 45 GeV where multiple scattering is negligible. This test beam setup provided the possibility to study properties of lead tungstate crystals (PbWO_4) for the BTeV experiment at Fermilab.Comment: 12 pages, 8 figures; work done by the BTeV Electromagnetic Calorimeter grou

    Expected Accuracy in a Measurement of the CKM Angle α\alpha Using a Dalitz Plot Analysis of \boldmath B^0 \to \rho \pi Decays in the BTeV Project

    Full text link
    A precise measurement of the angle α\alpha in the CKM triangle is very important for a complete test of Standard Model. A theoretically clean method to extract α\alpha is provided by B0ρπ^0 \to \rho \pi decays. Monte Carlo simulations to obtain the BTeV reconstruction efficiency and to estimate the signal to background ratio for these decays were performed. Finally the time-dependent Dalitz plot analysis, using the isospin amplitude formalism for tree and penguin contributions, was carried out. It was shown that in one year of data taking BTeV could achieve an accuracy on α\alpha better than 5^{\circ}.Comment: 26 pages, 11 figures. To be submitted to Phys.Atom.Nuc

    B Physics at the Tevatron: Run II and Beyond

    Full text link
    This report provides a comprehensive overview of the prospects for B physics at the Tevatron. The work was carried out during a series of workshops starting in September 1999. There were four working groups: 1) CP Violation, 2) Rare and Semileptonic Decays, 3) Mixing and Lifetimes, 4) Production, Fragmentation and Spectroscopy. The report also includes introductory chapters on theoretical and experimental tools emphasizing aspects of B physics specific to hadron colliders, as well as overviews of the CDF, D0, and BTeV detectors, and a Summary.Comment: 583 pages. Further information on the workshops, including transparencies, can be found at the workshop's homepage: http://www-theory.lbl.gov/Brun2/. The report is also available in 2-up http://www-theory.lbl.gov/Brun2/report/report2.ps.gz or chapter-by-chapter http://www-theory.lbl.gov/Brun2/report

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe
    corecore